• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.75.2009.tde-25082009-120021
Document
Author
Full name
Raphael Nagao de Sousa
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2009
Supervisor
Committee
Albuquerque, Hamilton Brandão Varela de (President)
Philadelphi, Laura Oliveira Peres
Santos, Mauro Coelho dos
Title in Portuguese
Efeito da temperatura na eletro-oxidação oscilatória de ácido fórmico sobre platina: experimentos e simulações
Keywords in Portuguese
(sobre)compensação
ácido fórmico
oscilações
Abstract in Portuguese
Ritmos biológicos são regulados por mecanismos homeostáticos que asseguram a confiabilidade funcional do relógio fisiológico independentemente de mudanças de temperatura no ambiente. Compensação de temperatura, ou a independência do período oscilatório em relação à temperatura, é conhecida por exercer um papel central em muitos ritmos biológicos, mas um fenômeno raro em osciladores químicos. Estudou-se nessa dissertação a influência da temperatura na dinâmica oscilatória durante a oxidação catalítica de ácido fórmico sobre eletrodo de platina policristalina. Os experimentos foram conduzidos em cinco temperaturas diferentes de 5 à 25 ºC, e as oscilações foram estudadas sob controle galvanostático. Resultados experimentais foram comparados a um novo modelo proposto para a eletro-oxidação de ácido fórmico, considerando formato como intermediário ativo e a desidrogenação da água em altos potenciais. Sob condições oscilatórias apenas comportamento anti-Arrhenius foi observado. Sobre-compensação com coeficiente de temperatura (q10, definido como a razão entre a constante de velocidade à temperatura T + 10 ºC e em T) < 1 é achada para a maioria dos casos, exceto em altas correntes aplicadas onde compensação de temperatura, q10 ~ 1 predomina. O comportamento do período e amplitude resulta de uma combinação complexa entre a temperatura e corrente aplicada ou, equivalentemente, a distância do equilíbrio termodinâmico. Altas energias de ativação aparente foram obtidas em condições voltamétricas, não-oscilatórias, as quais implicam que o comportamento anti-Arrhenius observado sob regime oscilatório resulta de um acoplamento entre as rotas reacionais em vez de uma fraca dependência da temperatura nas etapas elementares. Mecanisticamente, os experimentos e o modelo matemático sugerem que o período em regime de (sobre)compensação de temperatura durante a eletro-oxidação de ácido fórmico sobre platina é governado pelo acoplamento entre as taxas reacionais de formação/remoção de monóxido de carbono e formato em condições oscilatórias.
Title in English
Temperature effect in the oscillatory electro-oxidation of formic acid on platinum: experiments and simulations
Keywords in English
(over)compensation
formic acid
oscillations
Abstract in English
Biological rhythms are regulated by homeostatic mechanisms that assure that physiological clocks function reliably independent of temperature changes in the environment. Temperature compensation, i.e. the independence of the oscillatory period on temperature, is known to play a central role in many biological rhythms, but it is rather rare in chemical oscillators. It was studied in this master thesis the influence of temperature on the oscillatory dynamics during the catalytic oxidation of formic acid on a polycrystalline platinum electrode. The experiments are performed at five temperatures from 5 to 25 ºC, and the oscillations studied under galvanostatic control. Experimental results are compared to a new model proposed for formic acid electro-oxidation, which includes formate as an active intermediate and water dehydrogenation at high potentials. Under oscillatory conditions only non-Arrhenius behavior is observed. Over-compensation with temperature coefficient (q10, defined as the ratio between the rate constants at temperature T + 10 ºC and at T) < 1 is found in most cases, except that temperature compensation with q10 ~ 1 predominates at high applied currents. The behavior of the period and the amplitude result from a complex interplay between temperature and applied current or, equivalently, the distance from thermodynamic equilibrium. High, positive apparent activation energies were obtained under voltammetric, non-oscillatory conditions, which implies that the non-Arrhenius behavior observed under oscillatory conditions results from the interplay among reaction steps rather than from a weak temperature dependence of the individual steps. Mechanistically, the experiments and the mathematical model suggest that the period in temperature (over)compensation regime during electro-oxidation of formic acid at platinum is governed by the coupling among the reaction rates of formation/removal of carbon monoxide and formate coverage in oscillatory conditions.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
RaphaelNagaoR.pdf (2.71 Mbytes)
Publishing Date
2009-08-27
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.