Master's Dissertation
DOI
https://doi.org/10.11606/D.74.2016.tde-28112016-135201
Document
Author
Full name
Francis Massashi Horigoshi
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Pirassununga, 2016
Supervisor
Committee
Costa, Ernane José Xavier (President)
Brennecke, Käthery
Fiorelli, Juliano
Title in Portuguese
Uso de sensor efeito Hall para medição da vazão de fluidos no processo de produção de palatabilizantes a base de proteína animal em escala piloto
Keywords in Portuguese
Efeito Hall
Harware livre
Medidor de vazão
Otimização
Palatabilizantes
Abstract in Portuguese
Os medidores de vazão contribuem de forma significante para a otimização industrial onde o deslocamento contínuo de massa é parte integrante do sistema produtivo, sendo, portanto, cruciais para a indústria permitindo assim padronizar produtos e automatizar ações reduzindo a força de trabalho humana e minimizando erros. Este é o caso da produção de palatabilizantes, substâncias produzidas a partir da hidrólise enzimática da proteína animal para conferir aroma e sabor aos alimentos, onde existe um deslocamento continuo de massa com dosagem de fluidos acionadas em várias etapas do processo. Podem-se destacar duas etapas principais: a etapa onde ocorre a dosagem de soluções alcalinas para a hidrólise enzimática e a etapa onde ocorre a acidificação para garantir a segurança microbiológica do produto. No trabalho em questão foi desenvolvido e analisado um medidor de vazão de turbina por sensoriamento via efeito Hall, para determinar a vazão volumétrica de fludos no processo produtivo de palatabilizantes. O sistema utilizado na avaliação do medidor de vazão foi desenvolvido em escala piloto. A calibração do medidor permitiu-se calcular o fator K (coeficiente do medidor) tanto para água, onde o coeficiente foi de 5,5, quanto para palatabilizantes, onde o coeficiente calculado foi de 7. A partir dos dados obtidos pelo medidor de vazão pode-se observar um alto nível de correlação dos dados. O medidor de vazão apresentou-se eficaz para os fluidos testados (água e palatabilizante); e, com uma precisão de ± 2%, mostra-se uma alternativa viável para o processo de produção de palatabilizantes.
Title in English
Using Hall-effect sensor for measuring the fluid flow in the production process palatability animal protein based on a pilot scale
Keywords in English
Flowmeter
Free hardware
Hall effect
Optimization
Palatability
Abstract in English
Flowmeters contribute significantly to the industrial optimization where mass continuous displacement is an integral part of the production system, is therefore crucial for the industry allowing standardize products and automate actions reducing human labor and minimizing errors. This is the case of the production of flavors, substances produced from the enzymatic hydrolysis of animal protein to impart flavor and aroma to food, where there is a continuous mass displacement with fluids dosage triggered in several process steps. They can point out two main steps: a step where dosing occurs alkaline solutions for enzymatic hydrolysis and acidification stage which takes place to ensure the microbiological safety of the product. At work in question was developed and analyzed a turbine flowmeter for sensing via Hall effect to determine the volumetric flow fludos in the production of palatability process. The system used to assess the flow meter was developed on a pilot scale. The meter calibration allowed to calculate the K factor (the ratio meter) for both water where the ratio was 5.5, and for palatability, where the coefficient was calculated 7. From the data obtained by the flowmeter one can observe a high degree of correlation of the data. The flowmeter is made effective for the tested fluids (water and palatability); and with an accuracy of ± 2%, there is shown a viable alternative for the production of flavors process.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
ME7065131COR.pdf (1.30 Mbytes)
Publishing Date
2016-12-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.