Instrumentação eletrônica baseada em sensores poliméricos para medição de amônia em ambiente zootécnico
Mots-clés en portugais
Ambiência
Bem-estar animal
Polianilina
Zootecnia de precisão
Resumé en portugais
O presente trabalho teve como objetivo o desenvolvimento de um dispositivo para quantificar a amônia em concentrações de interesse zootécnico. Para tal, foi produzido um sensor, composto por dois eletrodos de ouro depositado em um substrato de vidro (BK7 vidro óptico) e revestido por um filme polimérico ultrafino de polianilina. Para testar o dispositivo desenvolvido, foram realizados experimentos laboratoriais expondo o mesmo a várias concentrações de amônia que possibilitou avaliação da resposta do referido dispositivo. As medições de capacitância do sensor foram realizadas utilizando uma ponte LCR e um circuito eletrônico ZSC 31210 da ZMD International. Os resultados mostram que o sensor proposto tem reversibilidade espontânea e possui resposta linear em função da concentração de amônia nas faixas de 1 a 40 ppm. Os resultados obtidos permitem concluir que a amônia produzida em ambiente de produção animal tem a possibilidade de ser monitorada e, por conseguinte, controlada por um sistema que use um sensor polimérico capacitivo de placas paralelas.
Titre en anglais
Electronic instrumentation based on polymeric sensors for ammonia measurement in livestock environment
Mots-clés en anglais
Ambience
Animal welfare
Livestock precision
Polyaniline
Resumé en anglais
This study aimed at the development and tests a device for measuring ammonia concentrations in livestock production. To accomplish this purpose, a polymeric sensor was developed by two gold electrode deposited on a glass substrate (BK7 optical glass) and coated with an ultrathin polymer film of polyaniline. In order to test the developed device, laboratory experiments were performed by exposing it at various concentrations of ammonia, which enabled to evaluate the response of the device. The capacitance of the sensor was performed using a LCR bridge and an electronic circuit ZSC31210 from ZMD International. The results show that, the proposed sensor is spontaneously reversible and has a linear response of ammonia concentration in the range from 1 to 40 ppm. Thus, the obtained results in this work indicate that, the ammonia produced in the animal production environment can be monitored and, therefore, controlled by a system using a parallel plate as a capacitor polymeric sensor.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
DO6521771COR.pdf (2.08 Mbytes)
Date de Publication
2014-08-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.