Tese de Doutorado
DOI
https://doi.org/10.11606/T.74.2012.tde-19082014-094707
Documento
Autor
Nome completo
Max Vicente
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Pirassununga, 2012
Orientador
Banca examinadora
Costa, Ernane José Xavier (Presidente)
Carvalho, Aparecido Augusto de
Dirani, Ely Antonio Tadeu
Franzolin Neto, Raul
Silva, Iran José Oliveira da
Título em português
Instrumentação eletrônica baseada em sensores poliméricos para medição de amônia em ambiente zootécnico
Palavras-chave em português
Ambiência
Bem-estar animal
Polianilina
Zootecnia de precisão
Resumo em português
O presente trabalho teve como objetivo o desenvolvimento de um dispositivo para quantificar a amônia em concentrações de interesse zootécnico. Para tal, foi produzido um sensor, composto por dois eletrodos de ouro depositado em um substrato de vidro (BK7 vidro óptico) e revestido por um filme polimérico ultrafino de polianilina. Para testar o dispositivo desenvolvido, foram realizados experimentos laboratoriais expondo o mesmo a várias concentrações de amônia que possibilitou avaliação da resposta do referido dispositivo. As medições de capacitância do sensor foram realizadas utilizando uma ponte LCR e um circuito eletrônico ZSC 31210 da ZMD International. Os resultados mostram que o sensor proposto tem reversibilidade espontânea e possui resposta linear em função da concentração de amônia nas faixas de 1 a 40 ppm. Os resultados obtidos permitem concluir que a amônia produzida em ambiente de produção animal tem a possibilidade de ser monitorada e, por conseguinte, controlada por um sistema que use um sensor polimérico capacitivo de placas paralelas.
Título em inglês
Electronic instrumentation based on polymeric sensors for ammonia measurement in livestock environment
Palavras-chave em inglês
Ambience
Animal welfare
Livestock precision
Polyaniline
Resumo em inglês
This study aimed at the development and tests a device for measuring ammonia concentrations in livestock production. To accomplish this purpose, a polymeric sensor was developed by two gold electrode deposited on a glass substrate (BK7 optical glass) and coated with an ultrathin polymer film of polyaniline. In order to test the developed device, laboratory experiments were performed by exposing it at various concentrations of ammonia, which enabled to evaluate the response of the device. The capacitance of the sensor was performed using a LCR bridge and an electronic circuit ZSC31210 from ZMD International. The results show that, the proposed sensor is spontaneously reversible and has a linear response of ammonia concentration in the range from 1 to 40 ppm. Thus, the obtained results in this work indicate that, the ammonia produced in the animal production environment can be monitored and, therefore, controlled by a system using a parallel plate as a capacitor polymeric sensor.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
DO6521771COR.pdf (2.08 Mbytes)
Data de Publicação
2014-08-20
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.