• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.74.2007.tde-13072007-142228
Document
Author
Full name
Camila Lúcio Pereira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Pirassununga, 2007
Supervisor
Committee
Savastano Júnior, Holmer (President)
Albuquerque, Ricardo de
Velloso Júnior, Walter Ferreira
Title in Portuguese
Avaliação do conforto térmico e do desempenho de frangos de corte confinados em galpão avícola com diferentes tipos de coberturas
Keywords in Portuguese
Cerâmica
Comportamento
Fibra de PVA
Frangos de corte
Polpa celulósica
Telhas
Abstract in Portuguese
O objetivo deste estudo foi avaliar o conforto térmico em galpão para criação de frangos de corte, tanto do ponto de vista das variáveis ambientais do micro-clima criado por diferentes tipos de coberturas, como no que se refere aos reflexos causados sobre os animais confinados nesse ambiente. O experimento foi realizado de outubro a dezembro de 2005. Foram utilizadas 330 aves da linhagem Cobb e 330 aves da linhagem CPK Isa Hubbard, distribuídas em três tipos de instalação: com cobertura de telha cerâmica, com telha não convencional de cimento com polpa celulósica de eucalipto e com telha não convencional de fibrocimento reforçada com fibras de PVA (polivinil álcool). O desempenho térmico das coberturas foi avaliado a partir dos índices de conforto térmico (carga térmica radiante, índice de temperatura de globo e umidade e índice de temperatura de globo). Foi realizada simulação do desempenho térmico das coberturas pelo método dos elementos finitos (FEM). Para os animais foram avaliadas: as variáveis fisiológicas de termorregulação (temperatura superficial média e perda de calor por radiação), as variáveis produtivas (consumo de ração, ganho de peso e conversão alimentar) e, o comportamento ingestório de alimento e água. Os índices de conforto térmico confirmaram maior estresse térmico às 14 h. Para o ITGU a telha cerâmica apresentou desempenho equivalente ao das demais coberturas em todos os horários, porém, às 14 h a telha de fibrocimento reforçada com fibras de PVA apresentou desempenho térmico inferior ao da cobertura de cimento com polpa celulósica. No horário mais quente não houve diferença entre os valores de CTR, o que indica desempenho térmico similar entre as coberturas testadas. O método dos elementos finitos mostrou-se uma boa ferramenta de trabalho na simulação do comportamento térmico das coberturas. A diferença genética entre as linhagens está relacionada às maiores médias de TSM e menores médias de PCR apresentadas pela linhagem CPK Isa Hubbard. A linhagem Cobb apresentou melhores índices produtivos em todos os tratamentos. As três coberturas avaliadas apresentaram desempenho térmico satisfatório, configurando as "telhas não convencionais" como nova opção comercial de cobertura para instalações zootécnicas.
Title in English
Evaluation of thermal comfort and fibercement tiles on the performance of broilers confined in poultry houses with different types of roofing
Keywords in English
Behavior
Broiler chickens
Cellulose pulp
Ceramic
PVA fiber
Tiles
Abstract in English
The aim of this study was to evaluate the thermal comfort in poultry houses for broiler chickens, considering environmental aspects of microclimate created by different types of roofing, and the consequences for animals confined in this environment. The trial was carried out from October to December 2005. It were used 330 Cobb line chicks and 330 CPK Isa Hubbard line chicks, distributed into three types of housing: ceramic tiles, non conventional tiles of cement with eucalypt cellulose pulp and non conventional tiles of fibercement reforced with PVA fibers (alcohol polyvinyl). The thermal performance of roofing was evaluated using thermal comfort indexes: radiant thermic load (RTL), globe temperature and humidity index (GTHI) and globe temperature (GT). The simulation of thermal performance of roofs was performed using the finite elements method (FEM). Considering the animals, it were evaluated physiological characteristics of thermoregulation (mean surface temperature and heat loss by radiation), productive parameters (feed intake, weight gain and feed conversion) and intake behavior of feed and water. The thermal comfort indexes confirmed higher thermal stress at 2 pm. For TGHI, the ceramic tiles presented similar performance compared with the other roofs in all times; however, at 2 pm the fibercement tile reforced with PVA fibers presented inferior thermal performance than the cellulose cement tile. At the hottest time, there was no difference between the RTL values, what indicates a similar thermal performance among the roofing tested. The FEM was showed as a good alternative on the thermal behavior simulation of roofing. The genetic difference among the broilers strains is related to the higher means surface temperatures and lower means for heat loss by radiation presented by the CPK Isa Hubbard line. The Cobb line presented better productive indexes in all treatments. The three roofs evaluated presented a satisfactory thermal performance, confirming the non conventional tiles as a new commercial option of roofing for animal housings.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
3342182.pdf (1.36 Mbytes)
Publishing Date
2007-07-13
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.