Master's Dissertation
DOI
https://doi.org/10.11606/D.7.2011.tde-21062011-120222
Document
Author
Full name
Ellen Regina Sevilla Quadrado
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Tronchin, Daisy Maria Rizatto (President)
Melleiro, Marta Maria
Toma, Edi
Title in Portuguese
Avaliação do processo de identificação do neonato de um hospital privado
Keywords in Portuguese
Avaliação de serviços de saúde
Enfermagem neonatal
Gerenciamento de riscos
Qualidade da assistência à saúde
Abstract in Portuguese
Trata-se de um estudo exploratório, descritivo de abordagem quantitativa, que teve por objetivo avaliar o processo de identificação do neonato admitido na unidade de terapia intensiva neonatal e semi-intensiva de um hospital privado no Município de São Paulo. A casuística compôs-se de 540 oportunidades de análise, selecionadas pela amostragem probabilística aleatória simples. A coleta de dados ocorreu no período de maio a agosto de 2010, por meio de um formulário, contendo as três etapas do processo de identificação: componentes de identificação, condições da pulseira e quantitativo de pulseiras. Os dados foram analisados em função da estatística descritiva, e sendo aplicado o teste estatístico com significância de 5%. No que diz respeito ao desempenho geral do processo, o percentual de conformidade foi de 82,2%. No que tange as três etapas integrantes do processo, o maior índice de conformidade (93%) foi atribuído a segunda etapa e o menor (89,3%) a terceira etapa, com diferença estatística significante (p=0,046). Em relação a primeira etapa, a presença do código de internação obteve (98,5%) de conformidade; na segunda,o melhor percentual (99,8%), foi atribuído à confecção correta da pulseira e na terceira, houve (88,5%) de conformidade para o grupo de neonatos em condições especiais, não apresentando diferença estatística significante p=0,895. Acredita-se que os achados deste estudo subsidiem as reestruturações necessárias no processo de identificação dos recém-nascidos e o estabelecimento de metas assistenciais e gerenciais, para a melhoria contínua da qualidade e da segurança dos pacientes.
Title in English
Evaluation of the identification procedure for newborns in a private hospital
Keywords in English
Health care quality
Health service assessment
Neonatal nursing
Safety management
Abstract in English
This is an exploratory, descriptive study of quantitative approach, aiming to evaluate the identification procedure for newborns admitted to a neonatal intensive and semi-intensive care unit of a private hospital in the city of São Paulo. The sample consisted of 540 opportunities for analysis, selected by the simple random probability sampling. Data collection occurred between May and August 2010, using a form containing the three phases of the identification procedure: identification components, conditions of ID bracelet and quantitative of ID bracelets. Data were analyzed according to descriptive statistics and the statistical test was applied with a significance of 5%. Regarding performance of the general process, the percentage of compliance was 82.2%. Regarding the three phases of the process, the highest compliance rate (93%) was related to the second phase and the lowest (89.3%) to the third phase, with a statistically significant difference (p = 0.046). Regarding the first phase, the presence of a hospitalization code obtained (98.5%) of compliance, in the second, the best percentage (99.8%) was attributed to correct manufacturing of the ID bracelet and third, with (88, 5%) of compliance for the group of newborns under special conditions, showing no statistically significant difference p = 0.895. It is believed that the findings of this study will subsidize the necessary reorganization of newborn identification procedure and establishment of assistance and management of goals for the constant improvement of quality and patient safety.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-06-21
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • QUADRADO, Ellen S., and TRONCHIN, Daisy Maria Rizatto. Evaluation of the identification protocol for newborns in a private hospital [doi:10.1590/S0104-11692012000400005]. Revista Latino-Americana de Enfermagem (USP. Ribeirão Preto. Impresso) [online], 2012, vol. 20, p. 659-667.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.