• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.7.2006.tde-15012007-143700
Document
Author
Full name
Caroline Dal Pian Alarcon Rocha
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Turrini, Ruth Natalia Teresa (President)
Graziano, Kazuko Uchikawa
Kawagoe, Julia Yaeko
Title in Portuguese
Esterilização a vapor em ciclo flash: análise das práticas realizadas pelos profissionais de enfermagem
Keywords in Portuguese
Esterilização a vapor
Infecção hospitalar (enfermagem)
Profissional de enfermagem
Abstract in Portuguese
A esterilização a vapor em ciclo flash refere-se a qualquer processo de esterilização a vapor que processe itens para uso imediato, sem nenhum empacotamento e com tempo insuficiente para secagem. A Association for the Advancement of Medical Instrumentation e a Association of Perioperative Registered Nurses recomendam-na para situações de emergência e trazem critérios específicos para sua utilização. Essa pesquisa teve como hipótese a utilização pelos profissionais de enfermagem da esterilização a vapor em ciclo flash não restrita a situações emergenciais, contrariando as recomendações oficiais e da literatura. Portanto, o objetivo desse estudo foi de analisar as práticas relacionadas à esterilização em ciclo flash. Para o alcance deste propósito, foram coletadas informações, através de um questionário, de pessoas em evento de abrangência nacional realizado pela Sociedade Brasileira de Enfermeiros em Centro Cirúrgico, Central de Material e Esterilização e Recuperação Anestésica (SOBECC), a fim de obter dados de como esse processo de esterilização tem sido executado. Dos 560 questionários entregues, 113 (20,1%) foram devolvidos. Das características dos respondentes, 89,1% eram enfermeiros, apresentavam idade entre 25 e 50 anos, com tempo médio de formação de 12,7 anos, sendo a maioria da região Sudeste. Cerca de 46,0% trabalhavam no Centro Cirúrgico (CC) e 36,0% no Centro de Material (CME), com uma média de atuação no serviço de 8,1 anos. Das características da instituição, 40,0% eram de instituições públicas e 72,0% de caráter geral. Em relação à utilização do ciclo flash, 41,0% realizavam-na em autoclaves convencionais, sendo que 69,0% tinham seus esterilizadores no CME, local também em que 73,4% realizavam a limpeza do material. Para essa atividade, 61,4% tinham regras definidas, e 12,7% o faziam sem detergente sendo que dos profissionais envolvidos nesse processo, 81,2% eram da enfermagem. Para situações de emergência mais de 90,0% utilizavam o método de esterilização flash, mas um número razoável de respondentes (38,0%) o utilizavam como rotina, o que confirmou a hipótese da pesquisa, demonstrando o não cumprimento das recomendações das diretrizes internacionais e sim, a “adequação" de um arsenal de instrumentos para atender a demanda cirúrgica. Dos que embalam o material (62,2%), 84,0% o reesterilizavam caso não fosse usado. A esterilização de implantáveis em flash é realizada por apenas 8,0%. Dos respondentes, 78,0% monitoravam o processo de alguma maneira, inclusive com indicador químico e biológico 46,7%. Quanto à associação da freqüência de uso do ciclo flash com a presença das autoclaves de mesa infere-se que a inserção desse equipamento no mercado tem estimulado a utilização desse ciclo pelos profissionais. No estudo, percebeu-se que os índices de quem o faz de maneira inadequada, considerando todo o reprocessamento, não são substimáveis, mas preocupantes. Por esses índices, as recomendações das diretrizes internacionais não podem ser questionadas, mas entende-se que o empenho em reeducar o profissional da saúde e não simplesmente proibí-lo sem dar maiores justificativas seja o melhor caminho. A esterilização a vapor em ciclo flash só deve ser realizada se todos os passos fundamentais no reprocessamento de materiais forem cumpridos
Title in English
Steam sterilization in flash cycle: analysis of the practical ones carried through by the nursing professionals
Keywords in English
Infection hospital (nursing)
Nursing professional
Steam Sterilization the
Abstract in English
The steam sterilization in flash cycle means any process of steam sterilization that processes items for immediate use, unwrapped and with insufficient time for drying. The Association for the Advancement of Medical Instrumentation and Association of Perioperative Registered Nurses recommend its for emergency situations and brings specific criteria for use. This research had as hypothesis that the use of steam sterilization in flash cycle by nursing professional is not restricted to emergency situations, opposing the official recommendations and literature. Therefore, the objective of this study was to analyze the practical ones related to the sterilization in flash cycle. For the reach of this intention, information had been collected, through a questionnaire, of people in a national event carried through by the Brazilian Society of Nurses in Surgical Center, Center of Material and Sterilization and Anesthesic Recuperation (SOBECC), in order to get given how this process of sterilization has been executed. Of the 560 questionnaires delivered, 113 (20.1%) had been returned. About the characteristics of the respondents, 89.1% were nurses, presented age between 25 and 50 years, with average time of formation of 12,7 years, being the majority of the Southeastern region, 46,0% worked in Surgical Center (CC) and 36.0% in the Center of Material (CME), with average of performance in the service of 8,1 years. About the characteristics of the institution, 40.0% were of public institutions and 72.0% of general character. In relation to the use of the flash cycle, 41.0% carry through in to the conventional sterilizers, being that 69.0% had its sterilizers in the CME, place where 73.4% carried through the cleanness of the material. For this activity, 61.4% had defined rules, and 12.7% made it without detergent being that of the involved professionals in this process, 81.2% were of nursing. For situations of emergency more than 90.0% used the flash sterilization method, but a reasonable number of respondents (38.0%) used it as routine, what it confirmed the hypothesis of the research, demonstrating not the fulfilment of the recommendations of the international lines of direction and yes, the “adequacy" of an armory of instruments to take care of the surgical demand. Of who packed the material (62.2%), 84.0% reprocessed it in case that he were not used. The flash sterilization of implanted is carried through by only 8.0%. Of the respondents, 78.0% monitored the process in some way, also with chemical and biological pointer 46.7%. How much to the association of the frequency of use of the flash cycle with the presence of the table sterilizers it is inferred that the insertion of this equipment in the market has stimulated the use of this cycle for the professionals. In the study, it was perceived that the indices of who make it in inadequate way, considering all the reprocessing, are preoccupying. By these indices, the recommendations of the international lines of direction cannot be questioned, but it understands that the persistence in reeducation the professional of health and not simply to forbid it without giving goods justifications is an optimum way. The steam sterilization in flash cycle must be carried through just if all basic steps in the reprocessing of materials will be fulfilled
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Carolina_Dal_Pian.pdf (1.60 Mbytes)
Carolina_Errata.pdf (142.89 Kbytes)
Publishing Date
2007-02-01
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • ROCHA, Caroline Dal Pian Alarcon, et al. Esterilização flash sob a ótica da evidência empírica. Revista SOBECC (São Paulo), 2008, vol. 13, p. 33-38.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.