• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.7.2018.tde-05112018-115921
Document
Author
Full name
Gabrielle Meriche Galvão Bento da Silva Guatura
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2017
Supervisor
Committee
Poveda, Vanessa de Brito (President)
Duran, Erika Christiane Marocco
Lopes, Camila Mendonça de Moraes
Turrini, Ruth Natalia Teresa
Title in Portuguese
Vigilância pós-alta em infecção de sítio cirúrgico: criação e validação de um instrumento
Keywords in Portuguese
Enfermagem
Estudo de validação
Infecção da ferida operatória
Infecção nosocomial
Abstract in Portuguese
Introdução: A infecção de sítio cirúrgico representa a terceira causa de infecção relacionada à assistência à saúde, que mais acomete pacientes na Europa e no Brasil. Considerando as altas hospitalares cada vez mais precoces e que grande parte das infecções do sítio cirúrgico se manifestará até o sétimo dia após a cirurgia, a vigilância pós-alta se faz extremamente necessária, uma vez que sua não realização pode levar a subnotificação, dificultando as ações de prevenção e controle. Existe carência, até o momento, de ferramentas que tenham sido validadas para a identificação de potenciais casos de ISC durante a vigilância pós-alta. Objetivo: Criar e validar um instrumento para a detecção pós-alta de potenciais casos de ISC. Método: Estudo psicométrico para a criação e validação de um instrumento, empregando-se as etapas de validação de conteúdo, critério e constructo. Resultado: O instrumento, após validação de conteúdo com juízes especialistas, apresentou coeficiente de validade de conteúdo total igual a 0,87. Para a validação de critério e constructo o instrumento proposto foi aplicado em uma amostra de 100 pacientes e comparado ao exame físico por profissional de saúde, observando-se coeficiente alfa de Cronbach igual a 0,87; Kappa de Cohen igual a 0,83; sensibilidade igual a 76,4%; especificidade de 100%; valores preditivo negativo de 92,5%, e preditivo positivo igual a 100%; precisão de 94%. Conclusão: O instrumento proposto foi validado e demonstrou ser uma ferramenta útil para detecção de possíveis casos de infecção de sítio cirúrgico na vigilância pós-alta.
Title in English
Postdischarge surveillance of surgical site infection: validation of an instrument
Keywords in English
Cross infection
Nursing
Surgical wound infection
Validation studies
Abstract in English
Introduction: Surgical site infection (SSI) represents the third cause of healthcare-associated infections, which affects patients in Europe and Brazil. Considering hospital discharges that are becoming more precocious and that most SSI will manifest themselves up to the seventh postoperative day, postdischarge surveillance is extremely necessary, since its failure to perform can lead to underreporting, making it difficult to prevention and control actions. There is a lack, until now, of tools that have been validated for the identification of potential cases of SSI during postdischarge surveillance. Objective: To create and validate an instrument for the postdischarge surveillance of potential SSI cases. Method: a psychometric study for the creation and validation of an instrument, using content, criterion and construct validation. Result: The instrument, after validating content with expert judges, presented coefficient of total content validity equal to 0.87. For the validation of criterion and construct the instrument was applied in a sample of 100 patients. Comparing the instrument to the physical examination by the health professional, Cronbachs Alpha was equal to 0.87; Cohen's Kappa was equal to 0.83; sensitivity equal to 76.4%; specificity of 100%; negative predictive values of 92.5%, and, positive predictive equal to 100%. The accuracy of the instrument was 94%. Conclusion: The proposed instrument was validated and constitutes a useful tool to detect possible cases of Surgical Site Infection in postdischarge surveillance.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-12-10
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.