Tesis Doctoral
DOI
https://doi.org/10.11606/T.7.2004.tde-25042006-141140
Documento
Autor
Nombre completo
Cristiane Giffoni Braga
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2004
Director
Tribunal
Cruz, Dina de Almeida Lopes Monteiro da (Presidente)
Coleta, Marilia Ferreira Dela
Garcia, Telma Ribeiro
Kimura, Miako
Pimenta, Cibele Andrucioli de Matos
Título en portugués
"Construção e validação de um instrumento para avaliação do sentimento de impotência"
Palabras clave en portugués
construção do teste
diagnóstico de enfermagem
locus de controle
psicometria
sentimento de impotência
Resumen en portugués
Sentimento de impotência é um conceito aceito como um foco clínico da prática de enfermagem. Os objetivos deste estudo foram: desenvolver e testar uma medida de sentimento de impotência para pacientes adultos; verificar se o sentimento de impotência é um construto distinto do de locus de controle e analisar a associação entre sentimento de impotência e locus de controle. Os itens foram desenvolvidos a partir das dimensões do modelo de impotência de White, Roberts (1993) e das características definidoras de impotência, segundo a North American Nursing Diagnosis Association. A validade de conteúdo foi afirmada para 23 itens pelo julgamento de seis juízes, segundo critérios estabelecidos por Pasquali (1998). Teste de inteligibilidade foi realizado com 25 pacientes e 21 itens foram retidos. O instrumento foi testado com 210 pacientes adultos de unidades médico-cirúrgicas para seleção de itens, confiabilidade e validade. Pela análise de itens, nove deles foram descartados. Os 12 itens remanescentes foram testados quanto à confiabilidade e à validade. Três subescalas geradas pela análise fatorial (Capacidade de Realizar Comportamentos, Capacidade de Tomar Decisões e Resposta Emocional ao Controle das Situações) não confirmaram o modelo de White, Roberts e demonstraram consistência interna entre 0,58 e 0,85. O alfa total foi 0,80. Estimativas iniciais de validade de critério e de construto foram obtidas com associações entre o instrumento desenvolvido e uma afirmação geral sobre a percepção de controle (p<0,000) e correlação daquele com escores de internalidade gerados a partir dos escores na Escala de Locus de Controle na Saúde (p=-0,33). Os itens da escala de Locus de Controle na Saúde foram bem discriminados dos itens de sentimento de impotência pela análise fatorial, sugerindo conceitos distintos. Com refinamento o instrumento de Medida do Sentimento de Impotência para pacientes adultos servirá de base para avaliar essa resposta psicossocial, definir e apreciar intervenções clínicas propostas para melhorar o conforto emocional de pacientes adultos.
Título en inglés
Construction and validation of the instrument for assessment powerlessness
Palabras clave en inglés
locus of control
nursing diagnosis
powerlessness
psychometry
test construct
Resumen en inglés
Powerlessness is a concept accepted as clinical focus of nursing practice. The aims of this study were: to develop and test a measure of powerlessness in adult patients; to verify whether powerlessness is a construct distinct from locus of control and to analyse the association between powerlessness and locus of control. Items were developed from the powerless dimensions of the White, Roberts (1993) model and from the defining characteristics of powerlessness according to the North American Nursing Diagnosis Association (2002, 2003). Content validity was supported for 23 itens through the rating of six experts following criteria established by Pasquali (1998). Intelligibility test was performed in 25 patients and 21 items were retained. The instrument was tested with 210 adult patients of medical-surgical wards for item selection, reliability and validity. Through item analysis nine items were discarded. The remaining 12 items were tested for reliability and validity. Three subscales generated by factor analysis (Ability to Perform Behaviors, Ability to Make Decisions and Emotional Responses to Personal Control) did not confirm the White, Roberts model, and demonstrated internal consistency ranging from .58 to .85. Total scale alpha was .80. Initial estimates of criterion-related and construct validity were documented with associations between the developed measure and a general statement on personal control perception (p<.000), and correlation with internality scores generated from scores on Health Locus of Control Scale (p=-.33).Items of Health Locus of Control were well discriminated from the powerlessness items through factor analysis, suggesting they are distinct concepts. With refinement the Measure of Powerlessness for Adult Patients will provide a basis for assessing this psychosocial response, definition and evaluating clinical interventions designed to enhance the emotional comfort of adult patients.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Cristiane_Giffoni.pdf (1.03 Mbytes)
Fecha de Publicación
2006-05-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.