• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.64.2011.tde-27022012-112202
Document
Auteur
Nom complet
Eduardo de Almeida
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Piracicaba, 2011
Directeur
Jury
Nascimento Filho, Virgilio Franco do (Président)
Lopes, Ricardo Tadeu
Menegário, Amauri Antonio
Parreira, Paulo Sérgio
Santelli, Ricardo Erthal
Titre en portugais
Determinação de metais na bacia do rio Piracicaba usando as técnicas de Difusão em Filmes Finos por Gradiente de Concentração (DGT) e Fluorescência de Raios X Dispersiva em Energia (EDXRF) e por Reflexão Total (TXRF)
Mots-clés en portugais
Bacia do rio Piracicaba
Difusão em filmes finos por gradiente de concentração
Fluorescência de raios X dispersiva em energia
Fluorescência de raios X por reflexão Total
Fração dissolvida e lábil
Metal
Resumé en portugais
O desenvolvimento e aplicação de métodos analíticos na avaliação das concentrações de metais nas frações dissolvida e lábil na bacia do rio Piracicaba são de relevante importância para o estudo do comportamento químico-ambiental desses metais e para seu monitoramento, devido ao impacto das atividades antropogênicas nessa bacia. A técnica de difusão em filmes finos por gradiente de concentração (DGT, do inglês diffusive gradients in thin-films), é uma promissora ferramenta analítica de amostragem, pois permite pré-concentração, análise temporal, remoção de interferentes, avaliação lábil e amostragem in situ. A quantificação dos metais pelas técnicas de fluorescência de raios X dispersiva em energia por reflexão total (TXRF, total reflection X-ray fluorescence analysis) para amostras líquidas e da fluorescência de raios X dispersiva em energia (EDXRF, energy dispersive X-ray fluorescence) para amostras sólidas, mostram-se interessantes devido ao caráter multielementar, simultâneo e não destrutivo da análise. Neste trabalho avaliou-se a DGT para a determinação de Cr, Mn, Co, Ni, Cu, Zn e Pb em águas naturais, utilizando-se como agente ligante a membrana de celulose P 81 e como meio difusivo, o papel cromatográfico 3 MM. Calcularam-se os fatores de eluição e coeficientes de difusão para estes metais. Estudou-se o efeito da substância húmica, em diferentes concentrações, no desempenho da DGT para esses metais, e os resultados foram comparados e concordantes com as frações livre e a ligada à matéria orgânica, calculadas pelo programa Visual MINTEQ. Compararam-se o agente ligante e o meio difusivo à base de celulose, utilizados neste trabalho, com os à base de gel de poliacrilamida, empregando-se o complexante Chelex-100. Avaliou-se a homogeneidade da retenção dos analitos e do grupo ligante fosfato sobre a superfície do agente ligante. Nesses ensaios utilizaram-se soluções sintéticas contendo os analitos em pH 5,5 e força iônica 0,05 mol L-1 (ajustados com NaNO3). As determinações foram realizadas por TXRF e EDXRF. Avaliaram-se os acoplamentos DGT-SRTXRF e da DGT-EDXRF para a determinação da fração lábil de Cr, Mn, Co, Ni, Cu, Zn e Pb em amostras de água da bacia do rio Piracicaba, através de imersão em laboratório e in situ. Esses resultados foram comparados com as concentrações dissolvidas desses metais determinados pela técnica de fluorescência de raios X por reflexão total com excitação por luz síncrotron (SRTXRF, synchrotron radiation total reflection X-ray analysis). Os valores de concentrações de Mn, Cu e Zn nas frações dissolvida e lábil foram comparados com os valores máximos estabelecidos pela legislação brasileira Nas amostragens in situ, nos cinco pontos de coleta, as concentrações de Mn dissolvido e lábil foram maiores que a concentração total máxima permitida para esse elemento. Os elmentos Cr, Co, Ni e Pb, nas amostras coletadas, apresentaram-se abaixo do limite de detecção das técnicas SRTXRF (dissolvido), DGT-SRTXRF (lábil) e DGT-EDXRF (lábil). Os limites de detecção para o Cr, Mn, Co, Ni, Cu, Zn e Pb foram de 2,2 a 10 'mü'g L-1 na SRTXRF, de 0,21 a 3,6 'mü'g L-1 e de 7,2 a 24 'mü'g L-1 na DGT-SRTXRF e DGT-EDXRF, respectivamente
Titre en anglais
Determination of metals in Piracicaba river basin using Diffusive Gradients in Thin Films, and Energy Dispersive X-ray Fluorescence (EDXRF) and Total Reflection (TXRF) techniques
Mots-clés en anglais
Diffusive gradients in thin films
Dissolved and labile fractions
Energy dispersive X-ray fluorescence
Metal
Piracicaba river basin
Total reflection X-ray fluorescence
Resumé en anglais
Analytical methods evaluation for metal dissolved and labile fractions determination in Piracicaba river basin is notable for metal-behavior studies in this environment as well as their monitoring due to anthropogenic activities. The diffusive gradients in thin films (DGT) is a promising sampling technique because of its pre-concentration, time-integrated, matrix interference removal, labile evaluation and in situ analytical features. The analytical techniques total reflection X-ray fluorescence (TXRF) for liquid samples and energy dispersive X-ray fluorescence (EDXRF) for solid samples analysis are advantageous due to simultaneous, multielemental and non-destructive characteristics. In this work, it was evaluated the DGT technique for Cr, Mn, Co, Ni, Cu, Zn and Pb determination in freshwater, using P 81 cellulose membrane as bind agent and 3 MM chromatographic paper as diffusive layer. Elution factors and diffusion coefficients were calculated for these metals. The humic acids effect on DGT performance was assessed and compared to free and humic acid bound metal fractions estimated by Visual MINTEQ software, in which agreement results were found. The paper-based DGT and gel-based one with Chelex-100 as bind agent were compared. The metal retention and phosphate group homogenization on P 81 membrane bind agent surface was studied. For these tests it was utilized a synthetic solution these metals containing with pH and ionic strength adjust to 5.5 and 0.05 mol L-1 (NaNO3), respectively. It was used the TXRF and EDXRF techniques for these metal quantifications. The DGT-SRTXRF and DGT-EDXRF were assessed in order to determine Cr, Mn, Co, Ni, Cu, Zn and Pb labile fractions in batch and in situ in Piracicaba river basin freshwater samples. These results were compared to their dissolved fractions by synchrotron radiation total reflection X-ray analysis, SRTXRF. The dissolved and labile Mn, Cu and Zn concentrations levels were compared to maximum allowed set by Brazilian legislation. The dissolved and labile Mn concentrations were higher than the maximum allowed in all five samples in situ sampling. Cr, Co, Ni, and Pb concentrations were lower than their limits of detection for dissolved fractions (SRTXRF) and labile ones (DGT-SRTXRF and DGT-EDXRF). The detection limits for Cr, Mn, Co, Ni, Cu, Zn and Pb were from 2.2 to 10 'mü'g L-1 for SRTXRF, from 0.21 to 3.6 'mü'g L-1 and from 7.2 to 24 'mü'g L-1 for DGT-SRTXRF and DGT-EDXRF, respectively
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Doutorado.pdf (3.26 Mbytes)
Errata.pdf (7.43 Kbytes)
Date de Publication
2012-02-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.