• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.64.2014.tde-26012015-150109
Documento
Autor
Nombre completo
Tuanne dos Reis Dias
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 2014
Director
Tribunal
Reis, Boaventura Freire dos (Presidente)
Kamogawa, Marcos Yassuo
Korn, Mauro
Martelli, Patrícia Benedini
Mattos, Wanessa Melchert
Título en portugués
Desenvolvimento de procedimentos analíticos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de vanádio em águas e estanho em alimentos
Palabras clave en portugués
Análises em fluxo
Cela de longo caminho óptico
Espectrofotometria
Estanho
Fotômetros baseados em LED
Microcontrolador
Vanádio
Resumen en portugués
Esta tese tem como foco o desenvolvimento de procedimentos analíticos automáticos, visando as determinações fotométricas de vanádio e de estanho em águas e em alimentos empregando o processo de multicomutação em fluxo. Um microcontrolador da família PIC e um programa escrito em linguagem Visual Basic 6.0 foram empregados para controle dos dispositivos e aquisição de dados. A unidade de detecção foi construída empregando LED de alto brilho e celas de fluxo com longo caminho óptico (50-200 mm) para ganho em sensibilidade. O módulo de análises, empregando bombas solenoide como propulsores de fluido e o fotômetro foram integrados, formando uma unidade compacta. A determinação de vanádio em águas, mineral e de rio, foi baseada na redução do V(V) à V(IV) com ácido ascórbico e posterior complexação com Eriocromo Cianina R (ECR). Empregando uma cela de 150 mm, o sistema apresentou resposta linear de 0,02 a 1,00 mg L-1, limite de detecção estimado em 13 ?g L-1, coeficiente de variação de 0,87% (n=10) e frequência analítica de 47 determinações por hora. Recuperações entre 89 e 109% foram obtidas para adição de V(V) nas amostras de águas. O procedimento para a determinação de estanho em alimentos foi desenvolvido empregando bomba de multi-seringa como unidade de propulsão de fluidos, cela de fluxo com caminho óptico de 200 mm e parada de fluxo de 50 s. Baseado na reação do Sn(IV) com o violeta de pirocatecol (PCV) na presença de surfactantes, o sistema apresentou resposta linear de 0,10 a 1,25 mg L-1, limite de detecção estimado em 0,04 mg L-1, coeficiente de variação de 1,30% (n=10) e frequência analítica de 49 determinações por hora. Recuperações entre 95 e 115% foram obtidas com a adição de Sn(IV) às amostras de alimentos.
Título en inglés
Development of analytical procedures employing multicommutation flow analysis systems for the photometric determination of vanadium in water and tin in foods
Palabras clave en inglés
Flow analysis
LED based photometer
Long flow cell
Microcontroller
Spectrophotometry
Tin
Vanadium
Resumen en inglés
Automatic analytical procedures for photometric determinations of vanadium in water and tin in foods were developed using the multicommutation flow analysis process. A microcontroller of the PIC family and a software written in Visual Basic 6.0 language were used for devices control and data acquisition. Detection unit was designed to use high brightness LED and long optical pathlength flow cells (50-200 mm) to improve sensitivity. The flow analysis module using solenoid mini-pumps as fluid propelling devices and the photometer were integrated in order to form a compact unit. The determination of vanadium in mineral and river waters was based on the reduction of V(V) to V(IV) with ascorbic acid and subsequent complexation with Eriochrome Cyanine R (ECR). Employing flow cell of 150 mm, the system presented linear response between 0.02 and 1.00 mg L-1, detection limit of 13 ?g L-1, variation coefficient of 0.87% (n=10) and sampling throughput of 47 determinations per hour. Recoveries between 89 and 109% were attained for vanadium spiked to mineral and river water. The procedure for determination of tin in foods was development employing a multi-syringe pump as fluid propelling device, a flow cell with optical pathlength of 200 mm and stop flow of 50 s. The procedure was based on the reaction of Sn(IV) with pyrocatechol violet (PCV) in the presence of surfactants, presented linear response between 0.10 and 1.25 mg L-1, detection limit of 0.04 mg L-1, variation coefficient of 1.30% (n=10) and sampling throughput of 49 determination per hour. Recoveries between 95 and 115% were attained for tin spiked samples
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-03-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.