• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.64.2014.tde-26012015-150109
Document
Author
Full name
Tuanne dos Reis Dias
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Piracicaba, 2014
Supervisor
Committee
Reis, Boaventura Freire dos (President)
Kamogawa, Marcos Yassuo
Korn, Mauro
Martelli, Patrícia Benedini
Mattos, Wanessa Melchert
Title in Portuguese
Desenvolvimento de procedimentos analíticos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de vanádio em águas e estanho em alimentos
Keywords in Portuguese
Análises em fluxo
Cela de longo caminho óptico
Espectrofotometria
Estanho
Fotômetros baseados em LED
Microcontrolador
Vanádio
Abstract in Portuguese
Esta tese tem como foco o desenvolvimento de procedimentos analíticos automáticos, visando as determinações fotométricas de vanádio e de estanho em águas e em alimentos empregando o processo de multicomutação em fluxo. Um microcontrolador da família PIC e um programa escrito em linguagem Visual Basic 6.0 foram empregados para controle dos dispositivos e aquisição de dados. A unidade de detecção foi construída empregando LED de alto brilho e celas de fluxo com longo caminho óptico (50-200 mm) para ganho em sensibilidade. O módulo de análises, empregando bombas solenoide como propulsores de fluido e o fotômetro foram integrados, formando uma unidade compacta. A determinação de vanádio em águas, mineral e de rio, foi baseada na redução do V(V) à V(IV) com ácido ascórbico e posterior complexação com Eriocromo Cianina R (ECR). Empregando uma cela de 150 mm, o sistema apresentou resposta linear de 0,02 a 1,00 mg L-1, limite de detecção estimado em 13 ?g L-1, coeficiente de variação de 0,87% (n=10) e frequência analítica de 47 determinações por hora. Recuperações entre 89 e 109% foram obtidas para adição de V(V) nas amostras de águas. O procedimento para a determinação de estanho em alimentos foi desenvolvido empregando bomba de multi-seringa como unidade de propulsão de fluidos, cela de fluxo com caminho óptico de 200 mm e parada de fluxo de 50 s. Baseado na reação do Sn(IV) com o violeta de pirocatecol (PCV) na presença de surfactantes, o sistema apresentou resposta linear de 0,10 a 1,25 mg L-1, limite de detecção estimado em 0,04 mg L-1, coeficiente de variação de 1,30% (n=10) e frequência analítica de 49 determinações por hora. Recuperações entre 95 e 115% foram obtidas com a adição de Sn(IV) às amostras de alimentos.
Title in English
Development of analytical procedures employing multicommutation flow analysis systems for the photometric determination of vanadium in water and tin in foods
Keywords in English
Flow analysis
LED based photometer
Long flow cell
Microcontroller
Spectrophotometry
Tin
Vanadium
Abstract in English
Automatic analytical procedures for photometric determinations of vanadium in water and tin in foods were developed using the multicommutation flow analysis process. A microcontroller of the PIC family and a software written in Visual Basic 6.0 language were used for devices control and data acquisition. Detection unit was designed to use high brightness LED and long optical pathlength flow cells (50-200 mm) to improve sensitivity. The flow analysis module using solenoid mini-pumps as fluid propelling devices and the photometer were integrated in order to form a compact unit. The determination of vanadium in mineral and river waters was based on the reduction of V(V) to V(IV) with ascorbic acid and subsequent complexation with Eriochrome Cyanine R (ECR). Employing flow cell of 150 mm, the system presented linear response between 0.02 and 1.00 mg L-1, detection limit of 13 ?g L-1, variation coefficient of 0.87% (n=10) and sampling throughput of 47 determinations per hour. Recoveries between 89 and 109% were attained for vanadium spiked to mineral and river water. The procedure for determination of tin in foods was development employing a multi-syringe pump as fluid propelling device, a flow cell with optical pathlength of 200 mm and stop flow of 50 s. The procedure was based on the reaction of Sn(IV) with pyrocatechol violet (PCV) in the presence of surfactants, presented linear response between 0.10 and 1.25 mg L-1, detection limit of 0.04 mg L-1, variation coefficient of 1.30% (n=10) and sampling throughput of 49 determination per hour. Recoveries between 95 and 115% were attained for tin spiked samples
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-03-06
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.