• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.64.2008.tde-25112009-100121
Documento
Autor
Nombre completo
Silvia Regina Pessoa de Meneses
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 2008
Director
Tribunal
Zagatto, Elias Ayres Guidetti (Presidente)
Basso, Luiz Carlos
Borges, Eduardo Poggi e
Jesus, Dosil Pereira de
Reis, Boaventura Freire dos
Título en portugués
Monitoramento de espécies químicas produzidas durante a fermentação alcoólica utilizando sistemas de análises em fluxo
Palabras clave en portugués
Análise em fluxo contínuo
Espectrofotometria
Química analítica
Resumen en portugués
Sistemas de análises químicas por injeção em fluxo envolvendo difusão gasosa foram projetados para a determinação espectrofotométrica de sulfeto e sulfito em melaços e caldos de cana de açúcar fermentados, visando a seleção de leveduras em função das quantidades destas espécies químicas produzidas durante o processo de fermentação. Os métodos para determinação de sulfeto e sulfito envolveram os reagentes N,Ndimetil- p-fenilenidiamino (DMPD) e verde de malaquita (MG), respectivamente. A reação entre DMPD e sulfeto, em presença de Fe(III) e em meio ácido, resulta na formação de azul de metileno (MB) que é monitorado a 668 nm. O sinal analitico é registrado sob forma de pico cuja altura é proporcional ao teor de sulfeto na amostra. A reação entre MG e sulfito, em meio alcalino, resulta na diminuição da absorbância de MG monitorada a 620 nm. O sinal analítico é registrado como pico invertido proporcional à concentração de sulfito. Os principais parâmetros envolvidos em ambas as determinações, tais como vazões, concentrações de reagentes, pH dos ambientes reacionais, temperatura, volume inserido da amostra, dimensões dos módulos de análises, bem como presença de tensoativos e eletrólitos concentrados foram investigados, permitindo a otimização dos sistemas. Devido às interações entre os analitos e os compostos contendo grupos carbonila existentes na matriz, bem como atrações eletrostáticas entre as espécies gasosas formadas e as partículas em suspensão, a etapa de volatilização dos analitos da amostra se constituiu em fator limitante quanto á utilização dos procedimentos em análises in situ. Neste sentido, a necessidade de tratamento prévio da amostra foi demonstrada. Os sistemas propostos são robustos e fornecem resultados precisos (d.p.r. < 2 %) com valocidade analítica de 30 eterminações por hora. As curvas analíticas se apresentam lineares até 5,0 mg L-1 S-S2- ou 25,0 mg L-1 S-SO2, os limites de detecção foram estimados como 0,04 e 0,7 mg L-1 de S-S2- e S-SO2, e os consumos de reagentes foram de 0,6 mg DMPD e de 0,002 mg MG por determinação. Emprego do método das adições-padrão foi sugerido parasuperação das interferências matriciais
Título en inglés
Analytical flow systems for monitoring some chemical species produced during sugar fermentation for ethanol production
Palabras clave en inglés
Analytical chemistry
Flow analysis
Spectrophotometry
Resumen en inglés
Flow injection systems involving gas diffusion were designed for spectrophotometric determination of sulfide and sulfite in fermented sugarcane juices and molasses, aiming at yeast selection relying on their amounts produced during fermentation process. N,N-dimethyl-p-phenylenediamine (DMPD) e malachite green (MG) were used for sulfide and sulfite determinations, respectively. Reaction of sulfide with DMPD was developed in the presence of Fe(III) under acidic conditions, and yielded molybdenum blue (MB), which was monitored at 668 nm. The analytical signal was recorded as a peak with height proportional to the sulfide content in the sample. Reaction of sulfite with MG was developed under alkaline conditions, and caused a MG absorbance lessening monitored at 620 nm. The analytical signal was recorded as an inverted peak proportional to the sulfite concentration. For both determinations, the main involved parameters such as flow rates, reagent concentrations, pH of the reaction media, temperature, sample inserted volume, manifold geometry, as well as the presence of surfactants and concentrated electrolytes were investigated, allowing further system optimization. Due to analyte interactions with the carbonyl groups of some chemical species in the sample, as well as electrostatic attractions of the formed gaseous species by the solid suspended particles, the volatilization step constituted itself in a limiting factor for applying the procedures to in situ analysis. In this context, the need for a previous sample treatment was suggested. The proposed systems are rugged and yield precise results (r.s.d. < 2 %) at a sampling rate of 30 determinations per hour. Linearity of the analytical curves was noted up to 5.0 mg L-1 S-S2- or 25.0 mg L-1 S-SO2, detection limits were estimated as 0.04 mgL-1 S-S2- and 0.7 mg L-1 S-SO2, and the reagent consumptions were 0.6 mg DMPD and 0.002 mg MG per determination. Exploitation of the standard addition method for overcoming matrix effects was suggested
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
ErrataSRPMeneses.pdf (14.43 Kbytes)
TeseSRPMeneses.pdf (1.35 Mbytes)
Fecha de Publicación
2009-12-01
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.