• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.64.2009.tde-11122009-150429
Document
Author
Full name
Felipe Rufine Nolasco
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Piracicaba, 2009
Supervisor
Committee
Bendassolli, Jose Albertino (President)
Coelho, Fernando Antonio Santos
Kamogawa, Marcos Yassuo
Title in Portuguese
Desenvolvimento de um sistema para avaliação do efeito da aplicação de processos oxidativos avançados no tratamento de efluentes líquidos contendo fenol ou cianeto
Keywords in Portuguese
Água residual
Efluentes
Oxidação
Ozônio
Abstract in Portuguese
Com o intuito de viabilizar, ambiental e economicamente, a degradação de algumas substâncias perigosas e recalcitrantes, presentes em águas e efluentes, foi desenvolvido um sistema para estudar a tratabilidade dessas substâncias, utilizando Processos Oxidativos Avançados POAs. As espécies escolhidas foram o fenol (C6H5OH) a 50 mg L-1 e o cianeto de potássio (KCN) a 20 mg L-1. Os resíduos químicos foram submetidos a tratamentos com diferentes doses de O3 (0, 2,4 e 4,8 g h-1), H2O2 (0, 150 e 300 mg L-1 para o fenol e 0, 60 e 120 mg L-1 para o cianeto) e UV (0, 8 e 32 watts), pois tais combinações promovem a geração de radicais hidroxila (OH), cujo potencial de oxidação é superior ao de cada oxidante individualmente. O sistema desenvolvido funciona em batelada com recirculação, possibilitando todas as combinações de interesse entre os oxidantes, com capacidade máxima de 300 mL de resíduo, volume adotado para todos os testes deste trabalho. O sistema é composto por uma coluna cilíndrica disposta na posição vertical, ligada a um reator UV. Outros equipamentos instalados são a bomba para a circulação do resíduo, o concentrador de O2, o ozonizador (0-24 g h-1), cujo gás é insuflado pela base da coluna, e seu excesso passa pelo destruidor de O3, composto por uma coluna preenchida com carvão ativado. A solução de H2O2 é adicionada ao sistema com o auxílio de uma seringa. A eficiência do processo de mineralização do fenol, foi avaliada através de 27 tratamentos (combinações) nos tempos de 15 e 30 minutos e pH 6,5. As amostras coletadas foram analisadas em equipamento Shimadzu TOC-5000A, obtendo-se a concentração de carbono orgânico total. Os dados foram submetidos à análise estatística (Fatorial e teste de Tukey, p<0,05). As combinações com os melhores resultados foram utilizadas para uma segunda etapa de testes, variando os tempos em 5, 15, 30 e 45 minutos. Os novos dados foram submetidos à análise estatística e, novamente, as combinações com melhores resultados foram utilizadas para avaliação do efeito do pH (6,5 e 9,5) na mineralização do fenol. A combinação O3 (4,8 g h-1) / UV (32 watts) / H2O2 (300 mg L-1), em pH 9,5, apresentou a melhor condição de tratamento em 30 minutos, proporcionando 99,7% de mineralização do fenol. O delineamento experimental do cianeto foi baseado nas melhores razões oxidante/resíduo obtidas para o fenol. Foi preparada solução 8,13 mg L-1 de CN previamente alcalinizada (pH 11,0). Os tempos estudados foram 1, 2, 4, 5 e 10 minutos e as amostras foram submetidas à análise de N-NO3 por espectrofotometria em sistema por análise em fluxo. Neste caso a combinação O3 (4,8 g h-1) / UV (32 watts), proporcionou 97,6% da oxidação do cianeto à NO3 em 7 minutos de tratamento. Os custos dos tratamentos nas melhores condições foram de R$ 11,08 por litro de fenol tratado e R$ 4,20 por litro de cianeto tratado. Concluiu-se que o sistema proposto foi eficiente no tratamento de ambos resíduos químicos (fenol e cianeto) em um curto período de tempo
Title in English
Development of a system to evaluate the effect of the application of advanced oxidative processes in the treatment of liquid effluents containing phenol or cyanide
Keywords in English
Effluent
Oxidation
Ozone
Waste water
Abstract in English
In order to facilitate, environmentally and economically, the degradation of some hazardous and recalcitrant substances, presented in waters and wastewaters, a system was developed to study the treatability of chemical substances using Advanced Oxidative Processes AOPs. The substances chosen were phenol (C6H5OH) at 50 mg L-1 and potassium cyanide (KCN) at 20 mg L-1. The chemical residues were submitted to treatments with different combinations and doses of O3 (0, 2.4, and 4.8 g h-1), H2O2 (0, 150 and 300 mg L-1 for phenol and 0, 60 and 120 mg L-1 for cyanide) and ultraviolet radiation (0, 8 and 32 watts), as these combinations promote the generation of hydroxyl radicals (OH), whose oxidation potential is greater than of each oxidant individually. The developed system works in batch treatments with recirculation, allowing all combinations of interests among the oxidants, with a maximum capacity of 300 mL of waste, adopted for all tests of this work. The system consists of a cylindrical column disposed in the vertical position and connected to a UV reactor. Other installed equipments are the pump for residual recirculation, the O2 concentrator, the ozonator (0-24 g h-1), which gas is blown from the base of the column and its excess is destroyed by the equipment composed of a glass column filled with granulate activated carbon. The solution of H2O2 is added to the system with the aid of a syringe. The efficiency of the mineralization of phenol was evaluated in 27 treatments in 15 and 30 minutes and pH 6.5. The collected samples were analyzed in Shimadzu TOC 5000A equipment, obtaining the concentration of total organic carbon (TOC). The obtained data were submitted to statistical analysis (Factorial and Tukey test, p<0.05). The combinations with the best results were used for a second phase of tests, varying the time at 5, 15, 30, and 45 minutes. The new data were submitted to statistical analysis and the best performing combinations were used to evaluate the effect of pH (6.5 and 9.5) in the mineralization of phenol. The combination of O3 (4.8 g h-1) / UV (32 watts) / H2O2 (300 mg L-1) at pH 9.5 showed the best treatment condition in 30 minutes, providing 99.7% of phenol mineralization. The experimental design of cyanide was based on the best oxidant/residue reasons obtained for phenol. A solution with 8.13 mg L-1 of CN previously alkaline (pH 11.0) was prepared. The treatment times were 1, 2, 4, 5 and 10 minutes and the samples were submitted to N-NO3 analysis by spectrophotometry system in flow injection analysis. In this case the combination O3 (4.8 g h-1) / UV (32 watts) provided 97.6 % of oxidation of the cyanide to NO3 in 7 minutes of treatment. The costs of treatments in the best conditions were R$ 11,08 per litter of phenol treated and R$ 4,20 per litter of cyanide treated. It can be concluded that the proposed system was effective in the treatment of both chemical residues (phenol and cyanide) in a short period of time
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2009-12-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.