Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.61.2010.tde-29072010-102449
Documento
Autor
Nome completo
Camila de Cassia Macedo
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Bauru, 2010
Orientador
Banca examinadora
Feniman, Mariza Ribeiro (Presidente)
Carvallo, Renata Mota Mamede de
Penna, Sílvia Helena Alvarez Piazentin
Título em português
Timpanometria em lactentes com fissura labiopalatina utilizando sonda de multifrequência
Palavras-chave em português
Audição
fissura labiopalatina
lactente
timpanometria
Resumo em português
Objetivos: O objetivo deste trabalho é descrever, comparar e analisar as características dos achados timpanométricos com sonda de tom prova nas frequências de 226 Hz, 678 Hz e 1000 Hz. Modelo: Estudo transverso Local de execução: Setor de Fonoaudiologia, Hospital de Reabilitação de Anomalias Craniofaciais, USP, Bauru. Participantes: Sessenta e oito pacientes com fissura labiopalatina, sem cirurgia prévia, de ambos os sexos, idade entre três e doze meses. Intervenções: anamnese, otoscopia e timpanometria de multifrequência. Resultados: Devido ao efeito de oclusão foi obtido 136 timpanogramas para a sonda de 226 Hz, 94 timpanogramas para a sonda de 678Hz e 135 timpanogramas para a sonda de 1000 Hz, em um total de 365 timpanogramas. A curva que demonstra maior ocorrência é a de Pico Único, isto nas três frequências de sonda: 79,41% em 226 Hz, 40,42% em 678 Hz e 37,04% em 1000 Hz. A curva de PD foi encontrada apenas nas frequências de 678 Hz e 1000 Hz com ocorrência de 5,32% e 1,48% respectivamente. O mesmo aconteceu com as curvas ASS e INV, sendo visualizadas 7,45% em 678 Hz; 8,89% em 1000 Hz para a curva ASS e 21,28% em 678 Hz, 24,44% em 1000 Hz para curva INV. A curva PL ocorreu em todas as freqüências de tom de sonda com porcentagem de 20,59%, 25,53%, 28,15% para as sonda de 226 Hz, 678 Hz e 1000 Hz, respectivamente. Conclusão: Nos achados timpanométricos dos lactententes deste estudo foram encontrados diferentes tipos de curvas, que incluíram os tipos Pico Duplo (PD), Assimétrica (ASS), Invertida (INV) e Plana (PL). Os resultados mostraram maior ocorrência de curvas do tipo Pico Único (PU) na sonda de 1000 Hz, para sonda de 226 Hz a prevalência foi de curvas do tipo PU apresentando também curva Plana (P). A sonda de 678 Hz apresentou todos os tipos de curvas, com uma maior ocorrência da curva do tipo PU.
Título em inglês
Multifrequency tympanometry in infants with cleft lip and palate
Palavras-chave em inglês
Cleft lip and palate
hearing
infants
tympanometry
Resumo em inglês
Aim: This study aimed to describe, compare and analyze the characteristics of tympanometric findings with 226 Hz, 678 Hz and 1000 Hz tone probes. Model: Cross-sectional Location: Department of Speech Pathology and Audiology, Hospital for Rehabilitation of Craniofacial Anomalies, USP, Bauru. Participants: Sixty eight subjects with cleft lip and palate, non-operated, both genders, aged between three and twelve months. Interventions: anamneses, otoscopy and multifrequency tympanometry. Results: Given the occlusion effect, of 365 tympanograms, 136 were obtained for the 226 Hz probe, 94 for 678Hz and 135 for 1000 Hz probe. Single-peak curve was the most prevalent at the three probe frequencies: 79.41% at 226 Hz, 40.42% at 678 Hz and 37,04% at 1000 Hz. PD curve was found at 678 Hz and 1000 Hz occurring 5.32% and 1.48% respectively. ASS and INV curves were visualized 7, 45% at 678 Hz; 8,89% at 1000 Hz for ASS and 21,28% at 678 Hz, 24,44% at 1000 Hz for a INV curve. PL curve occurred in all frequencies at 20.59%, 25.53%, and 28.15% for the 226 Hz, 678 Hz and 1000 Hz probes, respectively. Conclusion: Different kinds of curves were found including: Double peak(DP), asymmetric (AS), inverted (INV) and plan (PL). Results indicated most prevalence of single-peak curves for 1000 Hz probe. The 226 Hz probe showed single-peak and plan curves as well. The 678 Hz probe showed all kinds of curves being the single-peak the most prevalent.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
DissCamilaMacedo.pdf (725.53 Kbytes)
Data de Publicação
2010-08-27
 
AVISO: O material descrito abaixo refere-se a trabalhos decorrentes desta tese ou dissertação. O conteúdo desses trabalhos é de inteira responsabilidade do autor da tese ou dissertação.
  • Feniman, Mariza Ribeiro, et al. Multifrequency tympanometry in infants with cleft lip and palate. In 9th European Craniofacial Congress (ECC), Salzburg-Aústria, 2011. 9th European Craniofacial Congress (ECC) - Abstracts., 2011. Abstract. Available from: http://www.ecc21.eu.
  • MACEDO,CC, e Feniman, Mariza Ribeiro. Avaliação eletroacústica em lactentes com fissura labiopalatina: timpanometria. In I Simpósio Internacional de Fissuras orofaciais e Anomalias Relacionadas e VIII Encontro Científico de Pós-Graduação do HRAC-USP, Bauru-SP, 2009. Anais Simpósio Internacional de Fissuras orofaciais e Anomalias Relacionadas e VIII Encontro Científico de Pós-Graduação do HRAC-USP.BAURU-SP : WPOLLICE PRODUÇÕES, 2009. Resumo.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI