• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.61.2006.tde-19122006-141200
Documento
Autor
Nombre completo
Mônica Moraes Waldemarin Lopes
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2006
Director
Tribunal
Rezende, Maria Lucia Rubo de (Presidente)
Oliveira, Pedro Cesar Garcia de
Trindade Junior, Alceu Sergio
Título en portugués
Atividade muscular e alterações mandibulares em usuários de prótese fixa implanto suportada
Palabras clave en portugués
Eletromiografia
Implantes dentários
Reabsorção óssea
Resumen en portugués
Objetivo: As alterações na altura óssea da região posterior ao último implante mandibular em indivíduos reabilitados com próteses fixas implanto suportadas foram correlacionadas com força de mordida (FM) e com a atividade massetérica em função. Métodos: radiografias panorâmicas antes e 1 ano depois da reabilitação de 10 pacientes do Hospital de Reabilitação de Anomalias Craniofaciais (HRAC – USP), foram avaliadas quanto à presença de alteração dimensional óssea. A FM foi registrada por meio de um gnatodinamômetro. Eletromiografia dos masseteres foi realizada e traduzida pelos parâmetros: contração voluntária isométrica máxima (CVIM) durante 5 segundos, mastigação habitual de cenoura (MHC) e mastigação unilateral direita (MUD) e esquerda (MUE) com látex. Resultados: houve um aumento médio da altura óssea mandibular de 0,23 ±0,4 mm; a FM média foi 42 ±5,9 Kgf e a CVIM foi de 66,7 ±23,7 µV. Os valores médios para MHC foram: ato 0,52 ±0,02 s; ciclo 1,3± 0,67s e amplitude (potência) 85,98 ±19,53µV; para MUD com látex foram: ato 0,59s, ciclo 0,89 ±0,22s amplitude 86,93 ±26,67µV, e os da MUE com látex foram: ato 0,56s, ciclo 1,35 ±0,69s e amplitude 90,89 ±32,96µV. Somente houve significância estatística do lado direito entre alteração dimensional óssea e o ato da MHC (p= 0,036); do lado esquerdo com o ato da MUD com látex - lado de balanceio (p= 0,026). Conclusão: o aumento médio da altura óssea na região posterior da mandíbula não se correlacionou significantemente com a maioria dos parâmetros analisados, sugerindo que a duração, mais que a potência da atividade muscular pode ter influência nas alturas observadas.
Título en inglés
Muscular activity and mandibular bone changes on patients provided with implant-supported fixed prosthesis
Palabras clave en inglés
Bone resoption
Dental implants
Electromyography
Resumen en inglés
Objectives: Changes on mandibular high posterior to the most distally positioned implant on patients provided with implant-supported fixed prosthesis were related to bite force (FM) and functional maseteric activity. Methods: orthopantograms taken before and one year after rehabilitation of 10 patients from the Hospital for Rehabilitation of Craniofacial Anomalies (HRAC-USP) were evaluated. The FM was registered by a gnatodynamometer. Electromyography of masseteric muscle was performed and interpreted as follows: maximum voluntary isometric clench (CVIM) during 5 seconds, habitual chewing of carrot (MHC) and unilateral right (MUD) and left (MUE) chewing with latex. Results: there was a mean increases in mandibular bone high of 0,23 ± 0,4mm; the mean FM was 42 ±5,9Kgf and CVIM was 66,7 ± 23,7 µV. The mean values for MHC were: act 0,52± 0,02s; cycle 1,3± 0,67s and the voltage amplitudes 85,98± 19,53µV; for MUD with latex the values were: act 0,59s, cycle 1,35 ± 0,69s and voltage amplitudes 90,89± 32,96µV. There was only statistically significant difference between dimensional bone changes and act of MHI (p= 0,036) for the right side; and for the left side between MUD act with latex and balance side (p=0,026). Conclusions: the mean increase on bone high observed at the posterior region of the mandible was not significantly related to the majority of the analyzed parameters. This suggests that the lasting more than the amplitude of the muscular activity may have influenced the measurements observed.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
DISSMONICA.pdf (920.12 Kbytes)
Fecha de Publicación
2007-02-12
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.