Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.60.2010.tde-29102010-113037
Document
Auteur
Nom complet
Thiago Branco Hanna
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2010
Directeur
Jury
Gaitani, Cristiane Masetto de (Président)
Fonseca, Maria Jose Vieira
Martinis, Bruno Spinosa de
Titre en portugais
Avaliação do perfil in vitro de dissolução de comprimidos de mesilato de imatinibe empregando a cromatografia líquida de alta eficiência
Mots-clés en portugais
Cromatografia Líquida de Alta Eficiência.
Mesilato de imatinibe
Perfil in vitro de dissolução
Resumé en portugais
A leucemia mielóide crônica (LMC) é uma doença cujo marcador molecular é o rearranjo gênico BCR/ABL, original da translocação t(9;22), conhecida como cromossomo Philadelphia. Recentemente, os inibidores da enzima tirosina-quinase têm sido estudados e utilizados para o tratamento da LMC. Nesta classe, está o Mesilato de Imatinibe, uma pequena molécula que inibe competitivamente a BCR/ABL tirosina quinase, impedindo sua atividade. Por não possuir monografia publicada em compêndios oficiais, o objetivo deste trabalho foi avaliar o perfil in vitro de dissolução de comprimidos de mesilato em diferentes condições. A quantificação do fármaco foi feita utilizando a cromatografia líquida de alta eficiência em fase reversa (CLAE-FR) e as análises foram realizadas em uma coluna C18 Gemini Phenomenex®, utilizando como fase móvel tampão acetato de sódio 10,7 mmol/L, pH 3,0:metanol (40:60 v/v). O método foi validado e apresentou-se linear no intervalo de concentração de 10-150 µg/mL (r=0,9993). Os coeficientes de variação obtidos foram inferiores a 2,0 % e a exatidão próxima de 100 %. Também foram avaliados os parâmetros seletividade, robustez, estabilidade e limite de quantificação (10 µg/mL). A avaliação do perfil in vitro de dissolução foi realizada em três diferentes meios de dissolução (HCl 0,1 N, tampão acetato de sódio pH 4,5 e tampão fosfato de potássio monobásico pH 6,8), três velocidades de agitação (50, 75 e 100 rpm) e dois tipos de aparatos (pá e cesta). Os resultados obtidos neste teste indicaram que a forma farmacêutica em estudo é de liberação imediata, uma vez que foi verificada liberação de grande quantidade do fármaco em um curto período de tempo. A comparação dos perfis de dissolução, realizada através do cálculo da eficiência de dissolução, apresentou diferenças em relação à porcentagem do fármaco liberado. a condição mais adequada para avaliar o perfil in vitro de dissolução é o meio de dissolução HCl 0,1 N, aparato da pá e velocidade de agitação de 75 ou 100 rpm.
Titre en anglais
Evaluation of the in vitro dissolution profile of imatinib mesylate tablets using the high performance liquid chromatography
Mots-clés en anglais
In vitro dissolution profile.
High Performance Liquid Chromatography
Imatinib mesylate
Resumé en anglais
Chronic myeloid leukemia (CML) is a disease whose molecular marker is the BCR/ABL, original of the translocation t (9; 22), known as the Philadelphia chromosome. Recently, inhibitors of the enzyme tyrosine kinase have been studied and used for the treatment of CML. In this class, is the Imatinib mesylate, a small molecule that competitively inhibits BCR/ABL tyrosine kinase, preventing its activity. To do not have a monograph published in official compendia, the objective of this study was to evaluate the in vitro dissolution of tablets mesylate in different conditions. The quantification of the drug was made using high performance liquid chromatography on reversed phase (RP-HPLC) and analysis was performed on a Phenomenex® Gemini C18 column using a mobile phase of sodium acetate buffer 10.7 mmol/L pH 3.0:methanol (40:60 v/v). The method was validated and presented in a linear concentration range of 10-150 µg/mL (r=0.9993). The coefficients of variation obtained were below 2.0% and accuracy near 100%. We also evaluated the parameters selectivity, robustness, stability and limit of quantification (10 µg/mL). The evaluation of in vitro dissolution was conducted in three different dissolution media (0.1 N HCl, sodium acetate buffer pH 4.5 and potassium phosphate monobasic buffer pH 6.8), three agitation speeds (50, 75 and 100 rpm) and two types of devices (paddle and basket). The results of this tests indicated that the pharmaceutical form in question is immediate release, since it was observed release of large amounts of the drug in a short period of time. The comparison of dissolution profiles, conducted by calculating the dissolution efficiency, showed differences compared to the percentage of drug released. The best conditions to evaluate the in vitro profile of dissolution is the dissolution medium 0.1 N HCl, paddle apparatus and stirring speed of 75 or 100 rpm.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Thiago.pdf (603.06 Kbytes)
Date de Publication
2010-12-03
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.