• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.60.2010.tde-29102010-113037
Documento
Autor
Nombre completo
Thiago Branco Hanna
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2010
Director
Tribunal
Gaitani, Cristiane Masetto de (Presidente)
Fonseca, Maria Jose Vieira
Martinis, Bruno Spinosa de
Título en portugués
Avaliação do perfil in vitro de dissolução de comprimidos de mesilato de imatinibe empregando a cromatografia líquida de alta eficiência
Palabras clave en portugués
Cromatografia Líquida de Alta Eficiência.
Mesilato de imatinibe
Perfil in vitro de dissolução
Resumen en portugués
A leucemia mielóide crônica (LMC) é uma doença cujo marcador molecular é o rearranjo gênico BCR/ABL, original da translocação t(9;22), conhecida como cromossomo Philadelphia. Recentemente, os inibidores da enzima tirosina-quinase têm sido estudados e utilizados para o tratamento da LMC. Nesta classe, está o Mesilato de Imatinibe, uma pequena molécula que inibe competitivamente a BCR/ABL tirosina quinase, impedindo sua atividade. Por não possuir monografia publicada em compêndios oficiais, o objetivo deste trabalho foi avaliar o perfil in vitro de dissolução de comprimidos de mesilato em diferentes condições. A quantificação do fármaco foi feita utilizando a cromatografia líquida de alta eficiência em fase reversa (CLAE-FR) e as análises foram realizadas em uma coluna C18 Gemini Phenomenex®, utilizando como fase móvel tampão acetato de sódio 10,7 mmol/L, pH 3,0:metanol (40:60 v/v). O método foi validado e apresentou-se linear no intervalo de concentração de 10-150 µg/mL (r=0,9993). Os coeficientes de variação obtidos foram inferiores a 2,0 % e a exatidão próxima de 100 %. Também foram avaliados os parâmetros seletividade, robustez, estabilidade e limite de quantificação (10 µg/mL). A avaliação do perfil in vitro de dissolução foi realizada em três diferentes meios de dissolução (HCl 0,1 N, tampão acetato de sódio pH 4,5 e tampão fosfato de potássio monobásico pH 6,8), três velocidades de agitação (50, 75 e 100 rpm) e dois tipos de aparatos (pá e cesta). Os resultados obtidos neste teste indicaram que a forma farmacêutica em estudo é de liberação imediata, uma vez que foi verificada liberação de grande quantidade do fármaco em um curto período de tempo. A comparação dos perfis de dissolução, realizada através do cálculo da eficiência de dissolução, apresentou diferenças em relação à porcentagem do fármaco liberado. a condição mais adequada para avaliar o perfil in vitro de dissolução é o meio de dissolução HCl 0,1 N, aparato da pá e velocidade de agitação de 75 ou 100 rpm.
Título en inglés
Evaluation of the in vitro dissolution profile of imatinib mesylate tablets using the high performance liquid chromatography
Palabras clave en inglés
In vitro dissolution profile.
High Performance Liquid Chromatography
Imatinib mesylate
Resumen en inglés
Chronic myeloid leukemia (CML) is a disease whose molecular marker is the BCR/ABL, original of the translocation t (9; 22), known as the Philadelphia chromosome. Recently, inhibitors of the enzyme tyrosine kinase have been studied and used for the treatment of CML. In this class, is the Imatinib mesylate, a small molecule that competitively inhibits BCR/ABL tyrosine kinase, preventing its activity. To do not have a monograph published in official compendia, the objective of this study was to evaluate the in vitro dissolution of tablets mesylate in different conditions. The quantification of the drug was made using high performance liquid chromatography on reversed phase (RP-HPLC) and analysis was performed on a Phenomenex® Gemini C18 column using a mobile phase of sodium acetate buffer 10.7 mmol/L pH 3.0:methanol (40:60 v/v). The method was validated and presented in a linear concentration range of 10-150 µg/mL (r=0.9993). The coefficients of variation obtained were below 2.0% and accuracy near 100%. We also evaluated the parameters selectivity, robustness, stability and limit of quantification (10 µg/mL). The evaluation of in vitro dissolution was conducted in three different dissolution media (0.1 N HCl, sodium acetate buffer pH 4.5 and potassium phosphate monobasic buffer pH 6.8), three agitation speeds (50, 75 and 100 rpm) and two types of devices (paddle and basket). The results of this tests indicated that the pharmaceutical form in question is immediate release, since it was observed release of large amounts of the drug in a short period of time. The comparison of dissolution profiles, conducted by calculating the dissolution efficiency, showed differences compared to the percentage of drug released. The best conditions to evaluate the in vitro profile of dissolution is the dissolution medium 0.1 N HCl, paddle apparatus and stirring speed of 75 or 100 rpm.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Thiago.pdf (603.06 Kbytes)
Fecha de Publicación
2010-12-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.