Master's Dissertation
DOI
https://doi.org/10.11606/D.60.2010.tde-29102010-113037
Document
Author
Full name
Thiago Branco Hanna
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2010
Supervisor
Committee
Gaitani, Cristiane Masetto de (President)
Fonseca, Maria Jose Vieira
Martinis, Bruno Spinosa de
Title in Portuguese
Avaliação do perfil in vitro de dissolução de comprimidos de mesilato de imatinibe empregando a cromatografia líquida de alta eficiência
Keywords in Portuguese
Cromatografia Líquida de Alta Eficiência.
Mesilato de imatinibe
Perfil in vitro de dissolução
Abstract in Portuguese
A leucemia mielóide crônica (LMC) é uma doença cujo marcador molecular é o rearranjo gênico BCR/ABL, original da translocação t(9;22), conhecida como cromossomo Philadelphia. Recentemente, os inibidores da enzima tirosina-quinase têm sido estudados e utilizados para o tratamento da LMC. Nesta classe, está o Mesilato de Imatinibe, uma pequena molécula que inibe competitivamente a BCR/ABL tirosina quinase, impedindo sua atividade. Por não possuir monografia publicada em compêndios oficiais, o objetivo deste trabalho foi avaliar o perfil in vitro de dissolução de comprimidos de mesilato em diferentes condições. A quantificação do fármaco foi feita utilizando a cromatografia líquida de alta eficiência em fase reversa (CLAE-FR) e as análises foram realizadas em uma coluna C18 Gemini Phenomenex®, utilizando como fase móvel tampão acetato de sódio 10,7 mmol/L, pH 3,0:metanol (40:60 v/v). O método foi validado e apresentou-se linear no intervalo de concentração de 10-150 µg/mL (r=0,9993). Os coeficientes de variação obtidos foram inferiores a 2,0 % e a exatidão próxima de 100 %. Também foram avaliados os parâmetros seletividade, robustez, estabilidade e limite de quantificação (10 µg/mL). A avaliação do perfil in vitro de dissolução foi realizada em três diferentes meios de dissolução (HCl 0,1 N, tampão acetato de sódio pH 4,5 e tampão fosfato de potássio monobásico pH 6,8), três velocidades de agitação (50, 75 e 100 rpm) e dois tipos de aparatos (pá e cesta). Os resultados obtidos neste teste indicaram que a forma farmacêutica em estudo é de liberação imediata, uma vez que foi verificada liberação de grande quantidade do fármaco em um curto período de tempo. A comparação dos perfis de dissolução, realizada através do cálculo da eficiência de dissolução, apresentou diferenças em relação à porcentagem do fármaco liberado. a condição mais adequada para avaliar o perfil in vitro de dissolução é o meio de dissolução HCl 0,1 N, aparato da pá e velocidade de agitação de 75 ou 100 rpm.
Title in English
Evaluation of the in vitro dissolution profile of imatinib mesylate tablets using the high performance liquid chromatography
Keywords in English
In vitro dissolution profile.
High Performance Liquid Chromatography
Imatinib mesylate
Abstract in English
Chronic myeloid leukemia (CML) is a disease whose molecular marker is the BCR/ABL, original of the translocation t (9; 22), known as the Philadelphia chromosome. Recently, inhibitors of the enzyme tyrosine kinase have been studied and used for the treatment of CML. In this class, is the Imatinib mesylate, a small molecule that competitively inhibits BCR/ABL tyrosine kinase, preventing its activity. To do not have a monograph published in official compendia, the objective of this study was to evaluate the in vitro dissolution of tablets mesylate in different conditions. The quantification of the drug was made using high performance liquid chromatography on reversed phase (RP-HPLC) and analysis was performed on a Phenomenex® Gemini C18 column using a mobile phase of sodium acetate buffer 10.7 mmol/L pH 3.0:methanol (40:60 v/v). The method was validated and presented in a linear concentration range of 10-150 µg/mL (r=0.9993). The coefficients of variation obtained were below 2.0% and accuracy near 100%. We also evaluated the parameters selectivity, robustness, stability and limit of quantification (10 µg/mL). The evaluation of in vitro dissolution was conducted in three different dissolution media (0.1 N HCl, sodium acetate buffer pH 4.5 and potassium phosphate monobasic buffer pH 6.8), three agitation speeds (50, 75 and 100 rpm) and two types of devices (paddle and basket). The results of this tests indicated that the pharmaceutical form in question is immediate release, since it was observed release of large amounts of the drug in a short period of time. The comparison of dissolution profiles, conducted by calculating the dissolution efficiency, showed differences compared to the percentage of drug released. The best conditions to evaluate the in vitro profile of dissolution is the dissolution medium 0.1 N HCl, paddle apparatus and stirring speed of 75 or 100 rpm.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.