• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.60.2009.tde-25082009-143632
Document
Auteur
Nom complet
Juliana Andrade Nunes
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2009
Directeur
Jury
Barbosa Junior, Fernando (Président)
Forti, Juliane Cristina
Queiroz, Regina Helena Costa
Titre en portugais
Desenvolvimento de método para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se em sangue por espectrometria de massas com fonte de plasma acoplado indutivamente (ICP-MS) utilizando diluição das amostras em meio alcalino
Mots-clés en portugais
amostras de sangue
ICP-MS
metais.
método de preparo
preparo de amostras de sangue
TMAH
Resumé en portugais
A técnica analítica mais utilizada para o monitoramento de exposição a metais tóxicos ou para avaliação de deficiência a elementos essenciais é a espectrometria de absorção atômica chama (FAAS) ou com forno de grafite (GF AAS). Entretanto, cada vez mais os laboratórios de pesquisa na área clínica estão mudando seus métodos de análise, baseados nestas técnicas, para a utilização da espectrometria de massas com plasma acoplado (ICP-MS). Isso vem acontecendo porque o ICP-MS permite a determinação de elementos químicos, em diversas matrizes, numa ampla faixa de concentração (ng L-1 a mg L-1), além de possibilitar alta rapidez de análise, capacidade multielementar e limites de detecção menores que outras técnicas analíticas. Uma das principais características do método a ser utilizado para a análise de elementos químicos em rotina por ICP-MS é que ele seja rápido, com o mínimo de manipulação da amostra. Neste sentido, métodos que propõem a análise direta de amostra são mais atrativos. Todavia, ainda é limitado o número de métodos que propõem análise direta de fluidos biológicos por ICP-MS. Neste sentido, o presente trabalho teve como objetivo o desenvolvimento de um método para análise direta de sangue por ICP-MS para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se. Para isso, amostras de sangue (200 µL) foram misturadas com 500 µL de hidróxido de tetrametilamônio (TMAH) (10% v/v) e incubadas por 10 minutos. Posteriormente, a solução resultante foi diluída para 10 mL com uma solução contendo 0,05% m/v EDTA; 0,005% v/v Triton® X-100. Em seguida, as amostras foram analisadas diretamente por ICP-MS (ELAN DRC II). Ródio (Rh) foi usado como padrão interno e a calibração das amostras foi feita por meio de ajuste de matriz com sangue base ovino. Os limites de detecção (LD) do método foram de 0,008; 0,02; 0,004; 0,009; 0,003; 0,09; 0,04; 0,1 µg L-1 para Ag, As, Cd, Co, Mn, Ni, Pb and Se, respectivamente. A validação dos resultados foi realizada com análise de um material de referência de sangue do Programa de Proficiência do Institut National de Santé Publique du Quebec, no Canadá. Validação adicional foi obtida pela comparação dos resultados obtidos pela análise de 20 amostras de sangue pelo método proposto e pela técnica de GF AAS. O método foi também comparado a outros dois existentes na literatura e comumente utilizados em laboratórios dos Estados Unidos e Suécia, apresentando limites de detecção comparáveis ou melhores e melhores exatidão e precisão.
Titre en anglais
Development of a high-throughput method for assessment of Ag, As, Cd, Co, Mn, Ni, Pb and Se in blood samples by inductively coupled plasma mass spectrometry (ICP-MS)
Mots-clés en anglais
blood samples
ICP-MS
prepare method
TMAH
Resumé en anglais
The most used analytical technique for monitoring the exposure to toxic metals or for the assessment of the deficiency of essentials elements is the atomic absorption spectrometry with flame (FAAS) or graphite furnace (GF AAS). However, more and more clinical laboratories are changing their methods of analysis, based on this technique, to methods using inductively coupled plasma-mass spectrometry (ICP-MS). It occurs because ICP-MS allows the determination of chemical elements in various types of samples, at concentrations in a wide linear range (ng L-1 to mg L-1), providing high-throughput analysis with multielemental capability with lower detection limits. However, for routine porpuses the method of choice must be fast with minimal sample manipulation.On the other hand, the number of methods proposing direct introduction of biological fluids to the ICP-MS are still limited. This work aimed the development of a method for the direct analysis of blood samples by ICP-MS for the determination of Ag, As, Cd, Co, Mn, Ni, Pb and Se. For this, blood samples (200 L) were mixed with 500 L of tetramethylammonium hydroxide (TMAH) (10% v/v) and left at room temperature during 10 minutes. Subsequently, the resulting solution was diluted to 10 mL with a solution containing 0.05% m/v EDTA + 0005% v / v Triton ® X-100. Thus the samples were analyzed directly by ICP-MS (ELAN DRC II). Rhodium (Rh) was used as internal standard with matrix matching calibration. The method detection limits were: 0.008, 0.02, 0.004, 0.009, 0.003, 0.09, 0.04, 0.1 µg L-1 for Ag, As, Cd, Co, Mn, Ni , Pb, and Se respectively. Method validation was acquired with the analysis of blood reference material provided by the Institut National de Santé Publique du Quebec, Canada. Furthermore, for additional validation 20 ordinary blood samples were analyzed by the proposed method and by GF AAS. The method was also compared with two existing methods in the literature and commonly used in laboratories in the United States and Sweden where comparable or better detection limits and better accuracy and precision were obtained.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
JULIANAANDRADENUNES.pdf (763.45 Kbytes)
Date de Publication
2009-10-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.