• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.60.2010.tde-24052010-204423
Document
Auteur
Nom complet
Rafael Barcellos Bazzarella
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2010
Directeur
Jury
Martinis, Bruno Spinosa de (Président)
Guimaraes, Luiz Fernando Lopes
Malfará, Wilson Roberto
Titre en portugais
Desenvolvimento de metodologia analítica para a investigação de anfetaminas em amostras de saliva, empregando cromatografia em fase gasosa acoplada a espectrometria de massas
Mots-clés en portugais
Anfetaminas
Cromatografia em fase gasosa
Saliva
Resumé en portugais
O uso de drogas estimulantes por motoristas é reconhecidamente responsável por um aumento significativo na quantidade de acidentes nas estradas e rodovias. A própria exigência do trabalho muitas vezes acaba direcionando-os para a busca de algo que lhes proporcione maior estado de vigília e atenção nas estradas. Com base na importante correlação entre a profissão e o uso de substâncias anfetamínicas, foi proposta uma metodologia analítica para a determinação de anfetamina, metanfetamina, 3,4 metilenodioxianfetamina, 3,4 metilenodioximetanfetamina e 3,4 metilenodioxietilanfetamina em amostras de saliva através de técnica de extração líquido-líquido e análise por cromatografia em fase gasosa acoplada a espectrometria de massas (GC-MS). Para o desenvolvimento do método foi utilizado 1 mL de saliva, extração líquido-líquido com o solvente acetato de etila, derivatização com anidrido heptafluorobutírico (HFBA) e detecção com GC-MS. A metodologia foi validada e demonstrou linearidade de 10 a 400 ng/mL de saliva para todos os compostos. Os limites de detecção estabelecidos se encontraram entre 2,5 ng/mL e 7,5 ng/mL, enquanto os de quantificação foram de 10 ng/mL para todos os compostos. A exatidão apresentou valores entre 93,8% e 108,3%, a precisão intra-ensaio valores entre 4,05% e 9,34% e a precisão inter-ensaio valores entre 5,28% e 9,90%. A metodologia validada foi aplicada em amostras de saliva de caminhoneiros que trafegavam na região da cidade de Roseira SP em um evento de atendimento ao público promovido pela Sest/Senat (Serviço Social do Transporte/ Serviço Nacional de Aprendizagem do Transporte) em parceria com a Polícia Rodoviária Federal. Duas amostras de saliva de um total de 40 amostras analisadas apresentaram resultado positivo para anfetamina.
Titre en anglais
Development of analytical methodology for the investigation of amphetamines and derivatives in oral fluid samples using gas chromatography coupled with mass spectrometry
Mots-clés en anglais
Amphetamines
Gas chromatography
Saliva
Resumé en anglais
The use of stimulants by professional drivers is known as an increasing risk of accidents on the roads. The type of work itself induces the drivers to look out for something that provides better state of alertness and reduced sleep. Based on this important correlation between the occupation and use of stimulants, an analytical methodology was proposed for the determination of amphetamine, methamphetamine, and their methylenedioxy derivatives 3,4 methylenedioxyamphetamine, 3-4 methylenedioxymethamphetamine and 3,4 methylenedioxyethylamphetamine on oral fluid samples using solvent extraction and gas chromatography coupled with mass spectrum for detection and quantification of these analytes. The developed methodology used 1 mL of oral fluid, liquid-liquid extraction, heptafluorobutyric anhydride and gas chromatography-mass spectrometry for the detection and quantification. The methodology was validated and showed good linearity within the limits of 10 ng/mL and 400 ng/mL of oral fluid. The limits of detection were between 2.5 ng/mL and 7.5 ng/mL, while the limits of quantification were 10 ng/mL for all analytes. The accuracy showed values between 93.8% e 108.3%, the intra-assay precision between 4.05% e 9.34% and the inter-assay precision between 5.28% e 9.90%. The validated methodology was tested in oral fluid samples collected from truck drivers near the city of Roseira São Paulo during an event of health assistance fomented by SEST/SENAT in partnership with Federal Police. It was collected 40 saliva samples and two of them presented positive result for amphetamine.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Dissertacao.pdf (769.70 Kbytes)
Date de Publication
2010-12-02
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.