Disertación de Maestría
DOI
https://doi.org/10.11606/D.60.2006.tde-21052007-102053
Documento
Autor
Nombre completo
Igor Rafael dos Santos Magalhães
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2006
Director
Tribunal
Bonato, Pierina Sueli (Presidente)
Collins, Carol Hollingworth
Martinis, Bruno Spinosa de
Título en portugués
Análise enantiosseletiva da mefloquina em plasma: avaliação da técnica de microextração em fase líquida
Palabras clave en portugués
cromatografia líquida de alta eficiência
enantiômeros da mefloquina
microextração em fase líquida
plasma
Resumen en portugués
A mefloquina (MQ), fármaco utilizado na profilaxia e tratamento da malária ocasionada por Plasmodium falciparum resistente à cloroquina, é comercializada na forma racêmica. Apresenta disposição cinética estereosseletiva e ação farmacológica diferencial entre os enantiômeros. A maioria dos métodos analíticos desenvolvidos para análise do fármaco em plasma utiliza como técnicas de preparação das amostras, a extração líquido-líquido ou a extração em fase sólida. Por outro lado, a microextração em fase líquida (LPME), técnica recentemente desenvolvida, pode oferecer resultados bastante satisfatórios para amostras complexas, como fluidos biológicos. Portanto, o presente trabalho teve por finalidade o desenvolvimento e validação de um método analítico empregando a cromatografia líquida de alta eficiência com fases estacionárias quirais juntamente com a LPME para a análise enantiosseletiva da MQ em plasma. Empregando-se a coluna Chiralpak AD com fase móvel constituída por hexano/etanol/DEA (97:3:0,05, v/v/v), obteve-se a separação dos enantiômeros da MQ, com tempos de retenção reduzidos e resolução apropriada. Utilizando-se uma membrana capilar de polipropileno, juntamente com éter diexílico (fase orgânica) e ácido perclórico 10 mmol L-1 (fase aceptora) como componentes do sistema de três fases, obteve-se excelente isolamento dos interferentes endógenos aliado a um enriquecimento satisfatório dos analitos, sendo então possível a validação do método desenvolvido. A metodologia otimizada apresentou linearidade satisfatória no intervalo de 50 ? 1500 ng mL-1 com coeficientes de determinação > 0,998 para ambos enantiômeros. Os valores de recuperação absoluta de (-)-(SR)-MQ e (+)-(RS)-MQ foram 33,2% e 35,0%, respectivamente. Precisão e exatidão, avaliadas por estudos intra-ensaio e interensaio, foram < 15% para ambos enantiômeros. Além disso, não foram observadas racemização ou degradação do fármaco durante a preparação das amostras e análise cromatográfica. Posteriormente, o método desenvolvido e validado foi aplicado em um estudo-piloto de disposição cinética em ratos. Verificou-se que a disposição cinética da MQ em ratos foi estereosseletiva, já que maiores concentrações de (+)-(RS)-MQ foram obtidas em todos os tempos de análise avaliados.
Título en inglés
Enantioselective analysis of mefloquine in plasma: evaluation on the liquid-phase microextration technique
Palabras clave en inglés
high-performance liquid chromatography
liquid-phase microextration
mefloquine enantiomers
plasma
Resumen en inglés
Mefloquine (MQ), a drug used for prophylaxis and treatment of malaria caused by chloroquine-resistant strains of Plasmodium falciparum, is commercialized as a racemic mixture. MQ enantiomers demonstrate differential stereoselective dispositions and pharmacodynamic actions. The majority of methods developed for the determination of mefloquine in plasma includes liquid-liquid or solid-phase extraction as sample preparation. On the other hand, liquid-phase microextraction (LPME), a recently developed technique, may offer satisfactory results for complex matrices, such as biological fluids. Therefore, the aim of this work was to develop and validate an analytical method using chiral high-performance liquid chromatography combined with LPME for the enantioselective analysis of MQ in plasma. Employing a Chiralpak AD column with hexane/ethanol/DEA (97:3:0.05, v/v/v) as mobile phase, separation of MQ enantiomers was achieved with short retention times and appropriate resolution. Using a polypropylene-based capillary membrane together with di-n-hexyl ether (organic phase) and 10 mmol L-1 perchloric acid (acceptor phase) as components of a three-phase system, an excelent clean-up of endogenous interferents, allied with a satisfactory enrichment of analytes, was obtained, which allowed method validation. The optimized methodology exhibited good linearity over a 50 - 1500 ng mL-1 range with correlation coefficients of > 0.998 for both enantiomers. The mean recoveries of (-)-(SR)-MQ and (+)-(RS)-MQ were 33.2 and 35.0%, respectively. Precision and accuracy, demonstrated by within-day and between-day assays, were lower than 15% for both enantiomers. Furthermore, no racemization or degradation were seen during sample preparation and chromatographic analysis. Finally, the developed and validated method was applied to a pilot pharmacokinetic assay in rats. An enantiosselective kinetic disposition of MQ enantiomers was observed in rat plasma, as concentrations of (+)-(RS)-MQ were greater than its antipode at all measured times.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-05-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.