• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.60.2008.tde-10122008-222618
Document
Author
Full name
Naíssa Prévide Bernardo
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2008
Supervisor
Committee
Bonato, Pierina Sueli (President)
Gaitani, Cristiane Masetto de
Siqueira, Maria Elisa Pereira Bastos de
Title in Portuguese
Análise estereosseletiva do cloridrato de cis-tramadol e de suas impurezas em matéria-prima e formulação farmacêutica
Keywords in Portuguese
cromatografia líquida de alta eficiência
enantiômeros do cloridrato de cis-tramadol
fase estacionária quiral
formulação farmacêutica
impurezas
matéria-prima
Abstract in Portuguese
O cloridrato de tramadol, analgésico sintético de ação central, possui dois centros quirais: o isômero cis é ativo e o isômero trans é uma impureza de processo. Ambos os enantiômeros do cloridrato de cis-tramadol contribuem para o efeito analgésico, mas através de mecanismos diferentes, complementares e interativos farmacologicamente. Os dois isômeros do cis-tramadol apresentam efeitos terapêuticos, e a presença de impurezas, incluindo os isômeros trans - decorrentes do processo de síntese ou devido à decomposição - podem comprometer a qualidade do produto comercializado. Assim, este trabalho teve como objetivo desenvolver e validar metodologia estereosseletiva para análise do cloridrato de cis-tramadol e das possíveis impurezas quirais ou não na matéria-prima e formulações farmacêuticas. Para a separação e quantificação dos enantiômeros do cloridrato de cis-tramadol e das impurezas trans-tramadol, 1,2-olefina e 1,6-olefina, foi utilizada a coluna Chiralcel® OD-H, fase móvel constituída por hexano (60% e 100% de n-hexano, 1:1, v/v):isopropanol:dietilamina:ácido trifluoracético (99,5:0,5:0,3:0,1, v/v/v/v), na vazão de 0,7 mL min-1 e detecção em 274 nm. A coluna Chiralpak® AD fase móvel constituída por hexano (60% de n-hexano):etanol absoluto:dietilamina (95:5:0,1, v/v/v), na vazão de 1,0 mL min-1 e o comprimento de onda para detecção dos compostos foi de 228 nm foi utilizada para a separação e quantificação das impurezas O-desmetiltramadol, N-desmetiltramadol e tramadol N-óxido. Os métodos desenvolvidos foram devidamente validados através dos parâmetros seletividade, linearidade, precisão, exatidão, intervalo, limite de detecção e limite de quantificação. Os resultados obtidos na validação mostraram que os métodos são adequados para a determinação do cis-tramadol e de suas impurezas na matéria prima e na formulação farmacêutica.
Title in English
Estereoselective analysis of cis-tramadol hydrocloride and its impurities in raw material and pharmaceutical formulation
Keywords in English
chiral stationary phase
cis-tramadol hydrochloride enantiomers
high-performance liquid chromatography
impurities
pharmaceutical formulation
raw material
Abstract in English
Tramadol hydrochloride is a centrally acting analgesic with two chiral centers; the cis isomer is the active drug and the trans isomer is a process impurity. Both enantiomers of cis-tramadol hydrochloride contribute to the analgesic effect through different, but complementary and interactive pharmacological mechanisms. Although both isomers of cis-tramadol hydrochloride show therapeutic effects, the presence of impurities, originated from the synthesis process or due to degradation, can compromise the quality of the marketed product. The aim of this present work was the development and validation of a stereosselective methodology for the analysis of the drug cis-tramadol hydrochloride and the possible chiral or non-chiral impurities in raw materials and pharmaceutical formulations. The separation and quantitation of cis-tramadol enantiomers and the impurities trans-tramadol, 1,2-olefin and 1,6-olefin were carried out using a Chiralcel® OD-H column, mobile phase of hexane (60% and 100% of n-hexane, 1:1, v/v):2-propanol:diethylamine:trifluoroacetic acid (99,5:0,5:0,3:0,1, v/v/v/v) at a flow rate of 0,7 mL min-1 and detection at 274 nm. For the separation and quantitation of the impurities O-desmethyltramadol, N-desmethyltramadol and tramadol N-oxide, a Chiralpak® AD column was used with a mobile phase of hexane (60% of n-hexane):ethanol absolute: diethylamine (95:5:0,1, v/v/v) at a flow rate of 1,0 mL min-1 and detection at 228 nm. The methods were validated using the parameters selectivity, linearity, precision, accuracy, range, detection limit and quantitation limit. The results obtained show that the methods are suitable for the analysis of cis-tramadol and its impurities in raw material and pharmaceutical formulation.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
dissertacao.pdf (332.39 Kbytes)
Publishing Date
2008-12-23
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.