• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.60.2013.tde-05092013-111513
Document
Auteur
Nom complet
Dayanne Cristiane Mozaner Bordin
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2013
Directeur
Jury
Martinis, Bruno Spinosa de (Président)
Rothschild, Lilian
Barbosa, Hermes de Freitas
Titre en portugais
Exposição fetal: determinação de drogas de abuso em mecônio empregando a técnica de extração em fase sólida modificada e cromatografia em fase gasosa acoplada a espectrometria de massas
Mots-clés en portugais
Benzoilecgonina
Cocaetileno
Cocaína
Cotinina
Mecônio
Metil éster anidroecgonina
Nicotina
Resumé en portugais
O uso de drogas por mulheres em idade reprodutiva é considerado um grave problema de saúde pública mundial. O mecônio é a primeira excreção do recém-nascido e tem sido utilizado como uma matriz alternativa em análises toxicológicas. A extração em fase sólida (SPE) é um método amplamente utilizado para a purificação e concentração dos analitos em amostras biológicas no campo da análise forense. A maioria dos produtos de SPE convencionais requerem volumes relativamente grandes de solventes levando a um custo acrescido por amostra e um aumento no tempo de processamento da amostra. As ponteiras de extração com fase sólida modificada (DPX) foram utilizadas como uma alternativa aos cartuchos SPE tradicionais. A técnica combina eficiência e rapidez no procedimento de extração, com redução significativa no consumo de solvente e na quantidade de amostra. O objetivo desse estudo foi desenvolver e validar um método para a determinação de nicotina, cotinina, cocaína, benzoilecgonina, cocaetileno e éster metil anidroecgonina em amostras de mecônio usando DPX e cromatografia em fase gasosa acoplada à espectrometria de massa (GC/MS). Os resultados da validação indicaram uma extração eficiente, exata e precisa, com recuperação entre 50-98%, exatidão entre 92-106%, precisão intra-ensaio 4-12% e precisão inter-ensaio 6 a 12%. As curvas de calibração foram lineares com valores de R2 superiores a 0,99; os limites de detecção (LOD) variaram entre 2,5-15 ng/g e os limites de quantificação (LOQ) entre 10-20 ng/g. O método DPX-GC/MS mostrou ser eficaz para análise traços de drogas presentes em amostras de mecônio. Após desenvolvimento e validação, o método foi aplicado em 50 amostras de mecônio coletadas no berçário da Maternidade do Complexo Aeroporto (MATER) na cidade de Ribeirão Preto - São Paulo, Brasil.
Titre en anglais
Fetal Exposure: determination of drugs of abuse in meconium using solid phase extraction modified and gas chromatography coupled to mass spectrometry
Mots-clés en anglais
Benzoylecgonine
Cocaethylene
Cocaine
Cotinine
Meconium
Methyl ester anhydroecgonine
Nicotine
Resumé en anglais
Drug abuse by pregnant women is considered a serious public health problem worldwide. Meconium is the first excretion in newborns and has been used as an alternative matrix to evaluate in utero drug exposure. Solid phase extraction (SPE) is widely employed to prepare and cleanup samples in the field of forensic analysis. Most SPE products require large volumes of solvent, which culminates in longer sample processing times; increased cost per sample and higher limits of detection. Disposable Pipette Extraction tips (DPX) have been used as an alternative to traditional SPE cartridges. They combine efficient and rapid extraction with reduced solvent consumption. The purpose of this study was to develop and validate a method to determine nicotine, cotinine, cocaine, benzoylecgonine, cocaethylene and methyl ester anhydroecgonine in meconium using DPX and GC/MS. Validation results indicated extraction efficiency, ranged between 50-98%, accuracy 92-106%, intra-assay precision 4-12% and inter-assay precision 6 to 12%. Linear calibration curves resulted in R2 values greater than 0.99; limits of detection ranged from 2.5 - 15 ng/g and the limit of quantitation from 10 - 20 ng/g. The DPX-GC/MS method provided to selectively analyze trace concentrations of drugs in meconium samples. Finally, the developed and validated method was applied to 50 meconium samples collected at the nursery of Maternidade do Complexo Aeroporto (MATER) in the city of Ribeirão Preto - São Paulo, Brazil.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-10-29
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.