• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.6.2016.tde-23112015-122556
Document
Author
Full name
Cristiane Dias Poças
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Paganini, Wanderley da Silva (President)
Benassi, Roseli Frederigi
Mucci, José Luiz Negrão
Title in Portuguese
Utilização da tecnologia de wetlands para tratamento terciário: controle de nutrientes
Keywords in Portuguese
Leitos Cultivados
Wetlands Construídas
Zona de Raízes e Nutrientes
Abstract in Portuguese
As wetlands construídas estão entre as tecnologias eficientes recentemente comprovadas para tratamento e polimento de águas residuárias. Comparando com os sistemas convencionais de tratamento, são de baixo custo, fácil operação e manutenção. Esta pesquisa objetivou avaliar estudos de caso nacionais de utilização de wetlands para tratamento de efluentes em nível terciário com a finalidade de efetuar a remoção de nutrientes, buscando estabelecer parâmetros técnicos, operacionais e de manutenção. Foram avaliados sistemas que utilizaram como macrófita: Typha, Vetiver zizanioides L.Nash, Colocasia esculenta, Hedychium coronarium, Heliconia psittacorum, and Cyperus alternifolius; através de fluxos superficial e subsuperficial; o material filtrante foi brita e areia e o tempo de detenção hidráulica variou de 1,1 a 5 dias. Os resultados encontrados variaram de 5,6 por cento a 93,9 por cento para remoção de nitrogênio amoniacal e de 5 a 90,5 por cento para remoção de fósforo total. Constatou-se que a discrepância entre os resultados está associada ao tempo de detenção hidráulico utilizado, tipo de fluxo escolhido, material filtrante e manejo das macrófitas. Concluiu-se que a wetland construída pode ser usada como tratamento de efluentes em nível terciário para remoção de nutrientes, podendo-se afirmar que: a escolha da combinação de macrófita, material filtrante e fluxo deve ser feita de acordo com o efluente a ser tratado; não há um definição quanto ao tempo de detenção hidráulica ideal para cada sistema o que indica a necessidade de instalar pilotos para avaliação antes de implementar as estações em escala real; a poda deve ser feita respeitando o ciclo de desenvolvimento de cada espécie; é necessário realizar pesquisas que monitorem o sistema a longo prazo para avaliar o seu comportamento.
Title in English
The use of wetlands technology for tertiary treatment: the nutrients control
Keywords in English
Constructed Wetlands
Root Zone and Nutrients
Wetlands
Abstract in English
The constructed wetlands are among of the recently proven efficient technologies for treating and polishing of wastewater. Compared to conventional treatment systems, they are low cost, easily operated and maintained. This study aimed to evaluate national case studies of use of wetlands as a tertiary stage of wastewater treatment in order to make the removing of nutrients and establish technical, operational and maintenance parameters. The evaluated systems used as macrophyte: Typha, Vetiver zizanioides L.Nash, Colocasia esculenta, Hedychium coronarium, Heliconia psittacorum, and Cyperus alternifolius; through surface and subsurface flows; the filter material was gravel and sand and the hydraulic retention time ranged from 1.1 to 5 days. The results ranged from 5.6 per cent to 93.9 per cent for ammonia removal and from 5 to 90.5 per cent for total phosphorus removal. It was found that the discrepancy between the results is associated to the use of hydraulic detention time, to the type of flow, filter material and management of macrophytes. It was concluded that the constructed wetland can be used as tertiary stage of wastewater treatment for nutrients removal, it´s possible to say that: the combination between macrophyte, flow and filter material should be made in accordance with the effluent to be treated ; there is no definition as to the optimal hydraulic retention time for each system indicating the need to install a pilot treatment for evaluation before implementing the seasons full-scale; pruning should be done respecting the development cycle of each species; studies should be conducted to monitor the long-term system to evaluate their behavior.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-01-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.