• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.6.2006.tde-31102006-221659
Document
Author
Full name
Elizabeth Siqueira de Oliveira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Gallo, Paulo Rogerio (President)
Borges, Godofredo Campos
Carvallo, Renata Mota Mamede de
Lewis, Doris Ruthi
Siqueira, Arnaldo Augusto Franco de
Title in Portuguese
Triagem auditiva em recém-nascidos prematuros no município de Itapetininga, São Paulo
Keywords in Portuguese
Emissão otoacústica espontânea
Perda auditiva
Prematuridade
Saúde da criança
Triagem neonatal
Abstract in Portuguese
Objetivo. Este estudo teve como objetivo analisar os resultados de um programa de triagem auditiva neonatal em recém-nascidos pré-termos de um hospital público do município de Itapetininga, Estado de São Paulo. Métodos. A triagem auditiva neonatal foi realizada em 230 neonatos com idade gestacional variando de 28 a 37 semanas, por meio do exame de emissão otoacústica evocada produto de distorção, utilizando-se o equipamento AUDX Biologics. Foram analisados os seguintes aspectos do programa: a) as condições operacionais da realização da triagem auditiva no hospital pesquisado; b) as características da prematuridade presentes na população estudada; c) os resultados do programa de triagem em relação à identificação de casos com alterações auditivas; d) as amplitudes médias de resposta da emissão otoacústica evocada produto de distorção encontradas na população avaliada. Resultados. Foram avaliados 90,55% dos prematuros nascidos num período de 15 meses de coleta. Verificou-se que as condições operacionais para a realização do programa foram adequadas. Não foram encontrados casos de alterações auditivas. As amplitudes médias de respostas da emissão otoacústica evocada produto de distorção (PD-RF) variaram de 11 a 17 dBNPS, nas freqüências de 2 a 5 kHz; tendo sido observadas respostas superiores para as orelhas direitas do sexo feminino. Conclusões. Os prematuros constituíram uma população de baixo risco para deficiência auditiva. As amplitudes de respostas da emissão otoacústica com equipamento portátil mostraram-se semelhantes às obtidas com equipamentos clínicos. O programa de triagem auditiva neonatal pode ser realizado no hospital estudado. Porém, modificações na rotina devem ser realizadas para que possa ser implantado um programa universal.
Title in English
Hearing screening in preterm newborns from Itapetininga, São Paulo
Keywords in English
Child health
Hearing loss
Neonatal screening
Otoacoustic emissions
Prematurity
Abstract in English
Objective. The aim of this paper is to analyze the results of a newborn hearing screening programme applied to preterm infants from the city of Itapetininga, state of São Paulo. Methods. Newborn hearing screening was performed to 230 preterm newborns with gestational age from 28 to 37 weeks. The equipment used was AUDX Biologics performing the registry of otoacoustic emissions distortion product. The presence of cocleopalpebral reflex was performed too. It were analyzed: a) operational conditions of newborn hearing screening programme; b) the characteristics of infant?s prematurity; c) incidence of hearing impairment; d) amplitude of otoacoustic emissions distortion product responses (PD-NR). Results. The operational conditions of newborn hearing screening are suitable. No hearing impairment was identified, probably because the prematurity characteristics had load this group to low risk for hearing loss. The mean values from amplitude (PD-NR) extended from 11 to 17 dBSPL from 2 to 5 kHz. They were observed superior values to right ears of the female group. Conclusions. Newborn?s characteristics of prematurity showed low risk for hearing impairment in this study. Portable equipment responses are similar to clinic ones. Newborn hearing screening programme is feasible to be implemented at that kind of hospital. However, some adjusts need to be done in order to extends it to the universal protocol.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
ElizabethOliveira.pdf (1.07 Mbytes)
Publishing Date
2007-03-06
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.