• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.59.2017.tde-22122016-150338
Document
Author
Full name
Ana Cláudia Bordonal
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2016
Supervisor
Committee
Naal, Zeki (President)
Alves, Wendel Andrade
Fertonani, Fernando Luis
Tronto, Jairo
Valim, Joao Barros
Title in Portuguese
Materiais híbridos baseados em compostos lamelares e moléculas redox ativas
Keywords in Portuguese
Compósitos de HDL/óxido de grafeno
Compósitos e/ou Réplicas de carbono
Enzima Glicose Oxidase
Hidróxidos Duplos Lamelares
Abstract in Portuguese
Os Hidróxidos Duplos Lamelares (HDL) constituem uma classe de materiais que apresentam estrutura lamelar, consistindo de camadas positivamente carregadas de um hidróxido duplo, intercaladas com ânions hidratados no domínio interlamelar. Estes materiais têm recebido bastante atenção nos últimos tempos, devido ao baixo custo e relativa simplicidade de preparação, a possibilidade de combinação de uma variedade de cátions e ânions, aliados às propriedades que os HDL podem apresentar como: propriedades ácidas e básicas, "efeito memória", elevada área superficial, etc. Os HDL também podem ser utilizados em combinação com outros materiais, como por exemplo, óxido de grafeno, formando compósitos, com a finalidade melhorar as propriedades destes materiais. Podem ainda serem utilizados para a preparação de outros compósitos e/ou réplicas de carbono, por tratamento térmico de um HDL intercalado com um monômero, por exemplo, 4-vinil benzeno sulfonato (VBS), que pode ser polimerizado "in situ" e posteriormente carbonizado produzindo a réplica de carbono. A utilização dos materiais descritos anteriormente como suporte para imobilização de enzimas pode proporcionar uma plataforma alternativa para construção de dispositivos biossensores. O objetivo geral do trabalho foi a preparação e caracterização de materiais como HDL, Compósitos e/ou Réplicas de Carbono derivadas de HDL ou compósitos de HDL/ óxido de grafeno, como suporte da enzima Glicose Oxidase, estudando suas propriedades eletroquímicas, visando as potenciais aplicações destes materiais como biossensores. Para isto, foram preparados e caracterizados HDL de Mg-Al e Zn-Al intercalados com o ânion carbonato, pelo método de coprecipitação a pH variável; compósitos e/ou réplicas de carbono derivadas de um HDL precursor de Mg-Al-VBS, preparados, por coprecipitação a pH constante e compósitos de Mg-Al/óxido de grafeno que também foram preparados por coprecipitação a pH constante. Estes materiais foram utilizados na imobilização da enzima Glicose Oxidase (GOx), em eletrodos modificados e foi realizado o estudo eletroquímico dos mesmos e de suas potenciais aplicações. Foi possível observar que os HDL de Mg-Al-CO3, Zn-Al-CO3, Mg-Al-VBS e o compósito Mg-Al/óxido de grafeno exibiram boa cristalinidade, estabilidade térmica, e outras características como porosidade e superfícies positivamente carregadas, viabilizando a xiii utilização dos mesmos para a imobilização e estudo eletroquímico da enzima Glicose Oxidase. O estudo eletroquímico dos eletrodos modificados com estes materiais e a enzima Glicose Oxidase mostrou que os mesmos apresentam boa resposta catalítica frente ao substrato glicose e a importância destes materiais na atividade desta enzima. Os eletrodos modificados apresentaram boa sensibilidade, estabilidade à longo prazo e reprodutibilidade do método, podendo estes serem aplicados para a preparação de biossensores.
Title in English
"Hybrid Materials Based on Layered Compounds and Active Redox Molecules"
Keywords in English
Composites and/or Carbon Replica
Glucose Oxidase enzyme
Layered Double Hydroxides
LDH/ graphene oxide Composites
Abstract in English
Layered Double Hydroxides (LDH) constitute a class of materials with a layered structure consisting of positively charged layers of a double hydroxide and hydrated anions intercalated in the interlayer domain. These materials have received much attention lately because they offer many advantages: they display acidic and basic properties, "memory effect", and high surface area; are inexpensive and easy to prepare; and can combine with a variety of cations and anions. Combination of LDH with materials like graphene oxide affords composites with improved properties as compared to the starting organic component. Heat treatment of LDH intercalated with a monomer such as 4-vinyl-benzene sulfonate (VBS), followed by "in situ" polymerization and carbonization, produces composites and/or carbon replica. The materials described above could be applied as support to immobilize enzymes and may provide an alternative platform for biosensor devices. In this study, we aimed to prepare and characterize LDH, composites and/or carbon replica derived from LDH, and LDH/graphene oxide composites and support glucose oxidase enzyme (GOx) on these matrixes. We investigated the electrochemical properties of the resulting materials and evaluated their potential application as biosensors. More specifically, we prepared and characterized Mg-Al and Zn-Al LDH systems intercalated with carbonate ion by the coprecipitation method; composites and/or carbon replica derived from a precursor LDH Mg-Al-VBS by coprecipitation at constant pH; and Mg-Al/graphene composites by coprecipitation at constant pH. We used these materials to immobilize GOx on modified electrodes and assessed the electrochemical activity and potential application of the immobilized enzyme as biosensor. Mg-Al-CO3, Zn-Al-CO3, Mg-Al-VBS LDH and Mg-Al/graphene oxide composite were crystalline, thermally stable, and porous and exhibited positively charged surface, which favored immobilization and electrochemical investigation of the GOx enzyme. The modified electrodes displayed good catalytic response to glucose, as substrate, and improved the activity of the enzyme as compared to GOx alone. Additionally, the modified electrodes were sensitive, stable, and reproducible, paving the way for their use in the design of biosensors.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-02-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.