Master's Dissertation
DOI
https://doi.org/10.11606/D.59.2004.tde-20032004-145858
Document
Author
Full name
Leandro Maranghetti Lourenço
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2004
Supervisor
Committee
Andrade, Jose Fernando de (President)
Lima Neto, Benedito dos Santos
Naal, Zeki
Title in Portuguese
"Estudo espectrofotométrico do sistema crômio(III)/azoteto e seu aproveitamento analítico".
Keywords in Portuguese
azoteto
complexos
Crômio
cromo
espectrofotometria
Abstract in Portuguese
Na área de Química, uma das linhas mais tradicionais de pesquisa envolve o estudo de formação de complexos. Estes trabalhos são realizados de modo sistemático em nossos laboratórios, geralmente envolvendo cátions de metais de transição com vários ligantes (haletos, pseudo-haletos e carboxilatos). A intensa coloração desenvolvida pela maioria dessas reações de complexação, entre um metal e um pseudo-haleto, tem motivado o desenvolvimento de novos métodos espectrofotométricos para a determinação de íons em amostras reais. Espera-se que o crômio(III), da mesma forma que outros metais de transição, como o ferro, níquel e cobalto, forme complexos com o pseudo-haleto denominado azida ou azoteto (N3-). Desta forma, dando continuidade a esta linha de pesquisa, este trabalho teve como objetivo otimizar as condições experimentais para o sistema crômio(III)/azoteto. Diversos parâmetros como acidez, concentração de ligante, natureza e concentração de solvente, bem como o efeito da temperatura, foram investigados. Reunidas as melhores condições (otimização), montou-se o método analítico que possibilita a determinação do metal. As condições ideais empregadas foram: concentração analítica de ligante e ácido perclórico de 493 e 12,0 mmol L-1, respectivamente, numa temperatura de 25ºC, em meio aquoso. Para a determinação no ultravioleta, o tempo de espera para cada medida foi de 1 hora, enquanto que na região do visível, foi de apenas 30 minutos. Os máximos de absorção ocorreram em torno de 646, 480 e 287 nm, com coeficientes de absortividade molar médios de 184±1, 157±1 e (1,481±0,008) 104 L mol-1 cm-1, respectivamente. As condições estabelecidas foram promissoras, permitindo uma boa repetitividade nas regiões do visível e ultravioleta. Para o método desenvolvido, os íons mais interferentes na região do visível foram: Fe3+, Co2+ e Cu2+ e, na região do ultravioleta, foram HC8H4O4-, Fe3+, Cu2+ e Hg2+. Por meio de um sistema com duas equações, a determinação simultânea de crômio e ferro mostrou-se possível e com erros dentro dos limites analiticamente aceitáveis. Sem a utilização do sistema de equações, verificou-se ainda a possibilidade de se determinar crômio diretamente, mesmo na presença de ferro, no comprimento de onda de 646,5 nm, com um erro menor que 5%, desde que a concentração de ferro não ultrapasse 4 mg L-1. Aplicações analíticas para o método proposto foram testadas em dois suplementos alimentares contendo crômio. Os resultados foram comparados e mostraram-se concordantes com os da técnica de espectrometria de absorção atômica, para o suplemento contendo crômio quelato. Para o suplemento alimentar contendo picolinato de crômio, houve uma discordância dos resultados, indicando a existência de interferentes da matriz que não puderam ser eliminados. Um teste com uma amostra sintética de crômio mostrou um erro de cerca de 1,0% para o método proposto. Em condições ideais, e com um controle dos interferentes presentes, o método proposto mostra-se preciso, simples e barato. Considerando valores de absorbância entre 0,2 e 0,8 (faixa ideal), pode-se determinar o metal nos intervalos de 1,27 a 5,09 mmol L-1 a 480,5 nm, de 1,09 a 4,35 mmol L-1 a 646,5 nm e, finalmente, entre 0,702 a 2,81 mg L-1 no ultravioleta (287 nm).
Title in English
"Spectrophotometric study of chromium(III)/azide system and your analytical application".
Keywords in English
azide
chrome
Chromium
complexes
spectrophotometry
Abstract in English
In Chemistry, the study of complexes formation is one of the most traditional research lines. These studies are done under systematic manners in our laboratories, usually involving metallic transition cations with several ligands (halides, pseudohalides and carboxylates). The intense coloration developed by the major part of those complexation reactions, between a metal and a pseudohalide, has encouraged the development of new spectrophotometric methods for determination of ions in real samples. Conforming others transition metals, (iron, nickel and cobalt), which form complexes with the pseudohalide azide (N3-), we tried to observe the same behavior to chromium(III). Continuing this research line, this work had as principal objectives optimizes the experimental conditions for the chromium(III)/azide system. Several parameters were investigated as acidity, ligand concentration, nature and solvent concentration, as well as temperature effect for optimization of experimental conditions. Gathering all these conditions, the analytical methods were tested for the metal determination. The ideal conditions employed were: analytical ligand concentration and perchloric acid of 493 and 12.0 mmol L-l respectively, at 25 °C, in aqueous medium. For the studies in the ultraviolet region, the contact time before the measures was one hour, while for studies in the visible band measures were made after 30 minutes. The wavelengths of maximum absorption were encountered at 646, 480 and 287 nm, with molar absorptivity coefficients (mean) of 184±1, 157±1 and (1.481±0,008) 104 L mol-1 cm-1, respectively. The established conditions were promising, allowing a good precision in the visible and ultraviolet region. For the developed method, the more interfering ions on visible band were: Fe3+, Co2+ and Cu2+ and, on the ultraviolet band, were HC8H4O4-, Fe3+, Cu2+ and Hg2+. Through a system of two equations, the simultaneous determination of chromium and iron ions was possible with errors within the tolerance range. Without the simultaneous equations system, it was verified directly the possibility of chromium determination in the presence of iron, at a wavelength of 646.5 nm, with an error smaller than 5%, since the concentration of iron doesn’t exceed 4 mg L-l. In this proposed method, analytical applications were tested for two alimentary supplements containing chromium. The results were compared, being concordant with those of atomic absorption technique for the supplement containing chromium chelate, while for the alimentary supplement containing chromium picolinate, the results were in disagreement with the results, indicating the existence of matrix interferences which could not be eliminated. A test with a synthetic sample of chromium had an error of about 1.0% for the proposed method. Under ideal conditions, and with some control of possible interfering, the proposed method can be precise, accurate, simple and cheap. Considering the absorbance values between 0.2 and 0.8 (ideal range), the metal can be determined from 1.27 to 5.09 mmol L-l in 480 nm; 1.09 to 4.35 mmol L-l in 646 nm and, finally, from 0.702 to 2.81 mg L-l at 287 nm (ultraviolet).
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Dissertacao.pdf (1.14 Mbytes)
Publishing Date
2004-03-22
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors