• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2002.tde-19102006-204125
Documento
Autor
Nombre completo
Ana Paula de Oliveira Sader
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2002
Director
Tribunal
Andrade, Jose Fernando de (Presidente)
Bellingieri, Paulo Affonso
Naal, Zeki
Título en portugués
Estudo espectrofotométrico do sistema cobalto(II)/tiocianato e seu aproveitamento analítico
Palabras clave en portugués
cobalto
espectrofotométrico
tiocianato
Resumen en portugués
Estudos sobre a formação dos complexos de metais, seus equilíbrios e, também, o aproveitamento analítico desses diferentes sistemas constituem uma tradicional linha de pesquisa em Química. Mais especificamente, as espécies formadas entre os vários pseudo-haletos e outros ligantes, com muitos cátions dos metais de transição, vêm sendo sistematicamente investigadas em nossos laboratórios de Química Analítica. Nesta linha, o emprego do íon tiocianato como ligante tem se destacado dentre os métodos analíticos para a determinação de cobalto, cuja procura tem sido crescente à medida que o homem, ao longo de sua evolução, descobre e produz novos materiais contendo esse metal. Desta forma, tendo em vista algumas características típicas do sistema Co(II)/SCN-, tal como sua intensa coloração, objetivou-se, nesta oportunidade, explorá-lo espectrofotometricamente com maior profundidade. Conseqüentemente, diversos parâmetros envolvidos na complexação dos íons cobalto (II) pelo tiocianato, tais como: a acidez do meio, a concentração disponível de ligante e a presença de solventes orgânicos no sistema, tiveram seus efeitos avaliados individualmente. Com os resultados destes estudos, estabeleceram-se as condições experimentais otimizadas para a montagem do método analítico, visando a determinação de íons cobalto(II). São elas: C (HClO4) =0,050 mol L-1 C (SCN-)=0,203 mol L-1 C(THF)=60% (v/v) Através de estudos espectrofotométricos preliminares, observou-se que o sistema apresenta dois máximos de absorção nestas condições experimentais: 316 e 622 nm, sendo esta última banda, aquela normalmente utilizada neste tipo de trabalho. Estudos de calibração nos dois comprimentos de onda indicaram que as leituras obedecem fielmente à lei de Beer em ambos os casos, porém com sensibilidade significativamente maior na região ultravioleta (E(316nm)= 1,20 x 104 e E(622nm)= 1,95 x 103 L mol-1 cm-1). Outros estudos sobre estabilidade, repetibilidade (precisão) e de possíveis interferentes também foram realizados, sendo os resultados bastante satisfatórios para fins analíticos. Observou-se interferência das espécies: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+, Cd2+, quando presentes em concentrações cem vezes superiores à de cobalto(II). Entretanto, tal efeito desaparece quando estes íons acham-se em concentrações dez vezes maior do que a do metal de interesse. Aplicações analíticas do método proposto foram testadas em um produto farmacêutico (vitamina B12) e em uma liga odontológica, com resultados plenamente satisfatórios, já que os erros percentuais obtidos ficaram dentro da faixa aceitável (< 5%). A técnica de espectroscopia de absorção atômica foi utilizada paralelamente nestas análises, para efeito comparativo, na qual a determinação de cobalto mostrou-se possível na liga odontológica, mas inadequada para o fármaco (erro da ordem de 20%), nas condições de abertura realizadas. A comparação dos resultados mostra a potencialidade do método proposto, tendo em conta a simplicidade, exatidão e custo das aparelhagens. Finalizando, a possível influência do níquel (presente naturalmente em diversas amostras reais) na determinação de cobalto foi avaliada sob as condições experimentais estabelecidas para o método espectrofotométrico proposto. Observou-se que este “contaminante" natural exibe um pico de absorção em 245 nm e, através dos estudos, confirmou-se a aditividade das absorbâncias dos respectivos complexos (Co e Ni). Testou-se a possibilidade de determinação espectrofotométrica simultânea destes dois metais, através de leituras nos respectivos máximos (245 e 316 nm), empregando-se um sistema algébrico com duas equações simples, cujos resultados foram plenamente satisfatórios. As faixas úteis de trabalho, em termos de concentrações de cobalto e níquel foram, respectivamente: 0,94 a 4,04 mg L-1 e 28,7 a 123,7 mg L-1, respectivamente.
Título en inglés
Spectrophotometric study of cobalt(II)/thiocyanate system and its analytical use
Palabras clave en inglés
cobalt
spectrophotometric
thiocyanate
Resumen en inglés
Studies about the formation of metallic complexes, their equilibria and also the analytical utilization of these different systems represent a traditional research line in Chemistry. More specifically, the species formed among the various pseudohalides and other ligands, with several cations of transition metals, have been systematically investigated in our Laboratories. The use of the thiocyanate ion as ligand has been intensive from among the analytical methods for cobalt(II) determination, of which interest has increased more recently, according to the man discovers and production of new materials containing this metal. Due some typical characteristics of the system Co(II)/SCN-, such as its colored complexes, the principal purpose of this study was to explore it more carefully by visible-ultraviolet spectrophotometry. Consequently, several parameters involved in the cobalt(II)/thiocyanate complexes formation, such as acidity level, concentration of free ligand, and the percentage of organic solvents in the system, had their respective effects evaluated individually. Through the results of these diverse studies, appropriate experimental conditions were established for the analytical methods, for the determination of the cobalt(II) ion. They are: C (HClO4)=0.050 mol L-1 C (SCN-)=0.203 mol L-1 C(THF)=60% (v/v) Preliminary spectrophotometry studies showed two absorption maxima (peaks) under these optimized experimental conditions: 316 and 622 nm, being this last visible band normally applied for this type of work (determination). Calibration studies at these two wavelengths showed that the Beer’s Law is obeyed in both cases, but a higher sensitivity was obtained in the ultraviolet region ( E(316nm)= 1.20 x 104 e E(622nm)= 1.95 x 103 L mol-1 cm-1). Other studies about stability, precision, accuracy and possible interferences were also performed, showing satisfactory results for the analytical purposes. It was observed some interference of the following species: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+ and Cd2+, when present in concentrations one hundred times higher than the cobalt(II). However, this effect disappears when these ions are presented on concentration just ten times higher. Analytical applications of the proposed method were tested for a pharmaceutical product (B12 vitamin) and for an odontological alloy, with large success, since the percentage of error was within the tolerance range (<5%). Atomic absorption spectroscopy was also used in this analysis for comparision, in which the cobalt determination was possible for the alloy but inadequate for the pharmaceutical product (error about 20%). Comparison of the results shows the potentiality of this alternative spectrophotometric method, taking in account its simplicity, accuracy and equipments prices. Finally, the influence of nickel (naturally present in several real samples) on the spectrophotometric cobalt determination was evaluated, under the optimized experimental conditions. It was observed that this natural “contaminating" exhibits an absorption peak at 245 nm. Other confirmatory studies show the additivities of the respective absorbances (nickel and cobalt/thiocyanate complexes), allowing the simultaneous spectrophotometric determination of these these metals, using a matematical system with two equations (peaks 245 and 316 nm). This attempt was well satisfactory and the useful concentration ranges for cobalt and nickel were, respectively, 0.94 to 4.04 mg L-1 and 28.7 to 123.7 mg L-1.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
AnaPaulaSader.pdf (669.19 Kbytes)
Fecha de Publicación
2006-10-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.