Doctoral Thesis
DOI
https://doi.org/10.11606/T.59.2012.tde-17072012-142923
Document
Author
Full name
Lidervan de Paula Melo
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2012
Supervisor
Committee
Nassur, Maria Eugenia Queiroz (President)
Carvalho, Dermeval de
Chorilli, Marlus
Fernandes, Christian
Queiroz, Regina Helena Costa
Title in Portuguese
Desenvolvimento de métodos cromatográficos para análises de antimicrobianos em amostras complexas
Keywords in Portuguese
Cromatografia líquida
Parabenos
Polímeros molecularmente impressos.
Rifampicina
Abstract in Portuguese
Este trabalho descreve o desenvolvimento de novos métodos cromatográficos em conjunto com técnicas de microextração para determinação de parabenos em produtos cosméticos e leite humano e rifampicina em amostras de plasma. Destaca-se também o desenvolvimento da fase extratora molecularmente impressa para extração em fase sólida (SPE) de parabenos em amostras de leite humano. O capítulo I descreve a avaliação da extração sortiva em barra de agitação (SBSE) em conjunto com a cromatografia líquida (LC) com detecção espectrofotométrica (LC-UV) para análises de parabenos em produtos cosméticos para fins de controle de qualidade. As variáveis do processo de extração SBSE, tais como tempo e temperatura de extração, pH e força iônica da amostra e condições de dessorção foram otimizadas para aumentar a sensibilidade analítica do método e diminuir o tempo de análise. O método SBSE/LC-UV desenvolvido apresentou faixa linear correspondente ao limite de quantificação (LQ) a 2,50 µg. mg-1 e coeficientes de determinação maiores que 0,993. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 5,0% para todos os parabenos analisados e a exatidão variou de 90 a 100%. O método desenvolvido foi aplicado para análises de amostras de produtos cosméticos comerciais (cremes hidratantes, antitranspirantes em creme e filtros solares). O método SBSE/LC-UV padronizado e validado resultou nas seguintes vantagens em relação aos métodos convencionais: simplicidade no preparo de amostra, redução do volume de solvente orgânico e da quantidade de amostra utilizada. O capítulo II descreve o desenvolvimento da fase extratora molecularmente impressa para SPE de parabenos em amostras de leite humano e análises por cromatografia em fase líquida com detecção espectrofotométrica (SPE/LC-UV). Os polímeros de impressão molecular, materiais sintéticos baseados em sistemas biomiméticos, foram sintetizados através do processo sol-gel tendo como molde, o benzilparabeno. Após a remoção do molde, cavidades seletivas (sítios de reconhecimento molecular) ao benzilparabeno e análogos estruturais foram reveladas. O método SPE/LC desenvolvido apresentou faixa linear correspondente ao limite de quantificação a 150 ng. mL-1 e coeficientes de determinação 0,992. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 13% e a exatidão variou de 86 a 117%. A aplicabilidade do método SPE/LC foi demonstrada através das análises de amostras de leite humano de lactantes. Segundo os parâmetros de validação analítica avaliados, o método padronizado SPE/LC-UV é adequado para análises de parabenos em amostras de leite humano. O capítulo III descreve a avaliação da microextraçao em fase sólida no capilar (in-tube SPME) acoplada à cromatografia líquida (LC) com detecção espectrofotométrica (LC-UV) para análises de rifampicina em amostras de plasma para fins de monitorização terapêutica. As variáveis in-tube SPME, tais como fase estacionária da coluna capilar, volume de amostra, ciclos aspirar/dispensar e vazão foram otimizadas visando obter maior eficiência do processo. O método in-tube SPME/LC desenvolvido apresentou faixa linear correspondente ao limite de quantificação (0,1 µg. mL-1) a 100 µg. mL-1 e coeficientes de determinação igual a 0,998. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 2% e a exatidão variou de 83 a 92%. A aplicabilidade do método in-tube SPME/LC, padronizado e validado foi comprovada através das análises de amostras de plasma de pacientes em tratamento com rifampicina. O método in-tube SPME/LC resultou na automação do processo de análise, maior precisão analítica, menor tempo de análise, menor volume de solvente orgânico e de fluido biológico.
Title in English
Development of chromatographic methods for analysis of antimicrobials in complex samples
Keywords in English
Liquid chromatographic
Moleculary imprinted polymers
Parabens
Rifampicin
Abstract in English
This work describes the development of chromatographic methods in combination with microextraction techniques for the determination of parabens in cosmetic and human milk samples and of rifampicin in plasma samples. The design of a molecularly imprinted extraction phase for the solid-phase extraction (SPE) analysis of parabens in human milk samples is also reported. Chapter I describes the evaluation of the stir bar sorptive extraction (SBSE) in combination with liquid chromatography (LC) with UV detection (LC-UV) for the analysis of parabens in cosmetics aiming at quality control. The SBSE variables such as extraction time, temperature, pH of the matrix, ionic strength, and desorption conditions have been optimized, in order to establish the parabens partition equilibrium in a short analysis time. The linear range of the SBSE/LC method lay from LOQ to 2.5 µg. mg-1, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%, and the accuracy ranged from 90 to 99%. The effectiveness of the proposed method for the analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens has been proven. Therefore, the combination of SBSE with liquid desorption, followed by LC analysis, provides a simple, and selective tool for the analysis of parabens in cosmetic products using minimized volume of organic solvent as well as very small amount of the target sample. Chapter II presents the development of a molecularly imprinted extraction phase for the SPE analysis of parabens in human milk samples. The molecularly imprinted polymers, which are synthetic materials based on biomimetic systems, were synthesized by the sol-gel technology in the presence of the template (benzilparaben). After template removal, selective cavities (benzilparaben) were revealed for parabens selective extraction. The linear range of the SPE/LC method lay from LOQ to 150 ng. mL-1, with a coefficient of determination higher than 0.992. The interday precision of the SPE/LC method presented a coefficient of variation lower than 13%, and the accuracy ranged from 86 to 117%. The effectiveness of the proposed method for the analysis of human milk samples has been demonstrated. According to the evaluated analytical validation parameters, the SPE/LC-UV method is suitable for the analysis of parabens in human milk samples. Chapter III depicts the evaluation of solid-phase microextraction in the capillary (in-tube SPME) in combination with liquid chromatography (LC) with UV detection (LC-UV) for the analysis of rifampicin in plasma samples for therapeutic drug monitoring. The in-tube SPME/LC method was linear over the LOQ (0.1) to 100 g. mL-1 range, with a linear coefficient value (r2) of 0.998. The inter-assay precision presented coefficient of variation 2%, and the accuracy ranged from 83 to 92%. The effectiveness and practicability of the proposed method have been by analysis of plasma samples from ageing patients undergoing therapy with rifampicin. The in-tube SPME/LC method allowed for automated continuous sample preparation (extraction, concentration, desorption, and injection of analytes) and minimized the analysis time as well as the volumes of organic solvent and biological fluid.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
TESE.pdf (2.86 Mbytes)
Publishing Date
2012-10-04
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.