Título en portugués
Desenvolvimento de um sistema eletroquímico de análise por injeção em fluxo para detecção de cocaína
Palabras clave en portugués
analise por injeção em fluxo
bases de Schiff
cocaína
eletrodos quimicamente modificados
Química Forense
voltametria.
Resumen en portugués
O aumento nos índices de criminalidade, na maioria das vezes decorrente de atividades ligadas ao tráfico de drogas, afeta drasticamente a qualidade de vida do ser humano. A análise instrumental de entorpecentes é realizada comumente por métodos cromatográficos, oferecendo limites de detecção (LDs) em torno de 1 ng mL-1. As técnicas analíticas como voltametria, amperometria, potenciometria, dentre outras, assemelham-se às técnicas convencionais de análise, pois além de se mostrarem sensíveis para a análise de traços de substâncias orgânicas e inorgânicas, oferecem vantagens operacionais como a compreensão de mecanismos pato-fisiológicos de várias drogas, dentre elas a cocaína e seus metabólitos. Os eletrodos quimicamente modificados (EQMs) com bases de Schiff (grupos funcionais que contém uma ligação dupla carbono-nitrogênio com o átomo de nitrogênio conectado a um grupo arila ou alquila) desenvolvidos para a determinação de cocaína em amostras de interesse forense podem ser empregados em situação de análise por injeção em fluxo (FIA). Cuja metodologia consiste na inserção de uma alíquota de amostra em um fluido carregador que a transporta do ponto de injeção até a unidade de detecção. Atualmente a análise de cocaína está limitada à dosagem posterior de amostras apreendidas, uma vez que não há nenhum dispositivo portátil para a detecção da mesma em local de crime. Assim, este projeto visa desenvolver uma metodologia voltamétrica, por meio de eletrodos quimicamente modificados com bases de Schiff, e da aplicação dos mesmos em FIA para a detecção de cocaína em amostras de interesse forense.
Título en inglés
Development of an Electrochemical Flow Injection Analysis system for Detection of Cocaine
Palabras clave en inglés
chemically modified electrodes
cocaine
flow injection analysis
Forensic Chemistry
Schiff bases
voltammetry.
Resumen en inglés
The increase in crime occurrences, mostly due to activities linked to drug trafficking, dramatically affects the quality of human life. The instrumental analysis of drugs is commonly performed by chromatographic methods, offering limits of detection (LD) around 1 ng mL-1. Analytical techniques such as voltammetry, amperometry, potentiometry, among others, are similar to conventional analysis techniques, as well as prove sensitive for trace analysis of organic and inorganic substances, provide operational advantages as the understanding of pathophysiological mechanisms of several drugs, among them cocaine and its metabolites. The chemically modified electrodes (CMEs) with Schiff bases (functional groups containing a carbon-nitrogen double bond with the nitrogen atom attached to an alkyl or aryl group) developed for the determination of cocaine in samples of forensic interest can be used in situation of flow injection analysis (FIA). The methodology consists of inserting a sample rate of a carrier fluid that carries the point of injection to the detection unit. The analysis is limited to the dosage cocaine samples seized previously, since there is no portable device for detection in the same scene. Thus, this project aims to develop a voltammetric methodology, by means of chemically modified electrodes with Schiff bases, and applying them in the FIA for the detection of cocaine in samples of forensic interest.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Laura_corrigida.pdf (979.54 Kbytes)
Fecha de Publicación
2012-08-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.