• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.59.2014.tde-13012015-224604
Documento
Autor
Nombre completo
Matheus Manoel Teles de Menezes
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2014
Director
Tribunal
Naal, Zeki (Presidente)
Seron, Lucia Helena
Demets, Gregoire Jean Francois
Dockal, Edward Ralph
Farias, Robson Fernandes de
Título en portugués
Desenvolvimento de sensores voltamétricos e piezelétricos modificados quimicamente com cucurbiturilas para análises de cocaína em amostras de interesse forense
Palabras clave en portugués
cocaína
eletrodos quimicamente modificados
microbalança de cristal de quartzo
química forense
voltametria cíclica
Resumen en portugués
Considerando a relevância dos trabalhos onde se utiliza eletrodos quimicamente modificados e o pequeno número de estudos envolvendo cocaína e seus interferentes (cafeína, teobromina e lidocaína), por técnicas eletroquímicas ou piezelétricas, este estudo tem como objetivo o desenvolvimento de eletrodos de ouro e platina quimicamente modificados com compostos da classe das cucurbiturilas (CB[5], CB[6] e CB[7]) para a detecção de cocaína. A técnica de microbalança de cristal de quartzo foi empregada a fim de se estudar cocaína padrão e seus interferentes, em fase gasosa. Os eletrodos de ouro foram quimicamente modificados com cucurbiturilas e o modificador CB[6] apresentou os melhores resultados. Medidas por voltametria cíclica foram realizadas utilizando-se um potenciostato Autolab III acoplado a um computador, com eletrodo de ouro e platina atuando como eletrodo de trabalho, Ag/AgCl como eletrodo de referência e eletrodo espiral de platina como eletrodo auxiliar, com velocidade de varredura de 0,1 V.s-1 (100 mV.s-1). Os parâmetros voltamétricos foram otimizados para tornar as análises mais rápidas e sensíveis sem perda de qualidade ou intensidade do sinal voltamétrico. O eletrodo de platina quimicamente modificado com filme de cucurbit[6]urila apresentou aumento da corrente de pico catódica quando estudado frente à cocaína, teobromina e lidocaína. Análises com eletrodo de platina sem modificador químico apresentaram limite de detecção de 4,14.10-6 mol.L-1 e limite de quantificação de 1,38.10-5 mol.L-1 , para a cocaína, e na presença do modificador químico CB[6] apresentou limite de detecção de 1,36.10-6 mol.L-1 e limite de quantificação de 4,54.10-6 mol.L-1 . Eletrodos de ouro com ou sem a presença de modificadores químicos não apresentaram sinal para nenhum analito.
Título en inglés
Development of voltammetric and piezoelectric sensors chemically modified with cucurbiturils for analysis of cocaine in samples of forensic interest.
Palabras clave en inglés
chemically modified electrodes
cocaine
cyclic voltammetry
forensic chemistry
quartz crystal microbalance
Resumen en inglés
Considering the importance of chemically modified electrodes and the small amount of the cocaine study and their interfering (caffeine, theobromine and lidocaine) using electrochemical and piezoelectric techniques, this study aims to investigate the development of the gold and platinum electrodes chemically modified by cucurbiturils (CB[5], CB[6] and, CB[7]) in order to detect cocaine. The Quartz Crystal Microbalance technique was employed in order to study in gas phase the standard samples of cocaine and their interfering. Gold electrode was chemically modified with cucurbiturils films and the CB[6] modifier showed the best results. The cyclic voltammetric measurements were performed using a Autolab III potentiostat coupled to a computer, being gold and platinum as the working electrode, Ag/AgCl as the reference electrode and platinum wire as counter electrode, using a scan rate of 0,1 V.s-1 (100 mV.s-1). The voltammetric parameters were optimized in order to make the analysis faster and more sensitive without loss of intensity and quality of the voltammetric signal. The platinum electrode modified by cucurbit[6]uril film showed an increase of cathodic current peak when electrode was exposed to cocaine, theobromine and lidocaine. Analysis employed platinum working electrode without chemical modifier showed a detection limit of 4.14 . 10-6 mol.L-1 and quantification limit of 1.38 . 10-5 mol.L-1 for cocaine and with chemical modifier CB[6] showed a detection limit of 1.36 . 10-6 mol.L-1 and quantification limit of 4.54 . 10-6 mol.L-1 . Gold electrodes with or without chemical modifiers showed no response for any analyte.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Capacorrigida.pdf (299.03 Kbytes)
Fecha de Publicación
2015-02-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.