Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2012.tde-07122012-100400
Documento
Autor
Nombre completo
Marcelo Cardoso Ferreira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2012
Director
Tribunal
Nassur, Maria Eugenia Queiroz (Presidente)
Chaves, Andréa Rodrigues
Moraes, Luiz Alberto Beraldo de
Título en portugués
Padronização e validação analítica do método de extração em fase sólida de levoglucosano em amostras de água de chuva com análises por cromatografia gasosa acoplada à espectrometria de massas
Palabras clave en portugués
amostras de água de chuva
cromatografia gasosa acoplada à espectrometria de massas
Levoglucosano
quitosana
SPE
validação analítica.
Resumen en portugués
Neste trabalho, o método de extração em fase sólida (SPE) com análises por cromatografia gasosa acoplada à espectrometria de massas (GC-MS) foi desenvolvido para a determinação de levoglucosano em amostras de água de chuva da região de Ribeirão Preto-SP, Brasil. O monossacarídeo levoglucosano foi proposto como um marcador específico para queima de biomassa, uma vez que o mesmo é liberado durante a pirólise da celulose em temperaturas acima de 300ºC. Após a otimização das variáveis SPE, as melhores condições dentre as avaliadas foram as seguintes: cartuchos SPE recheados com a fase extratora quitosana (1,0 g), volume de amostra igual a 5,0 mL, vazão de 1,0 mL min-1, solvente de eluição: metanol (volume igual a 2,5 mL), sem a adição de sal. O método SPE/GC-MS para a determinação de levoglucosano em amostras de chuva apresentou faixa linear no intervalo de concentração de 0,05 µg mL-1 a 0,50 µg mL-1, r 0,9967, exatidão de 95 a 110% e precisão inter ensaios com coeficientes de variação (CV) menores que 15%, exceto para o limite de quantificação (0,05 µg mL-1) o qual apresentou CV inferior a 20%. Segundo as determinações (SPE/GC-MS) de levoglucosano em amostras de água de chuva coletadas no período 03/08/2011 à 09/04/2012, as concentrações médias de levoglucosano na safra de cana-de-açúcar são aproximadamente quatro vezes superior ao período de entressafra. Este fato é justificado pela elevada taxa de queima da palha da cana-de-açúcar na região de Ribeirão Preto-SP no período safra, e consequentemente, maior emissão de material particulado para a atmosfera incluindo levoglucosano, COD, entre outros.
Título en inglés
Standardization and validation of analytical method for solid phase extraction of levoglucosan in rainwater samples with analysis by gas chromatography coupled to mass spectrometry
Palabras clave en inglés
analytical validation.
chitosan
GC/MS
Levoglucosan
rainwater samples
SPE
Resumen en inglés
In this work, the method of solid phase extraction (SPE) with gas chromatography - mass spectrometry (GC-MS) analysis was developed for the determination of levoglucosan in rainwater samples collected in the region of Ribeirão Preto-SP, Brazil. The monosaccharide levoglucosan (1,6-Anhydro--D- Glucopyranose) was proposed as a specific marker for biomass burning, since it is released during the pyrolysis of cellulose at temperatures above 300 ° C. After optimization of the SPE variables, the best conditions were found to be as follows: SPE cartridges filled with the extraction phase chitosan (1,0 g), sample volume equal to 5,0 mL, flow rate of 1,0 mL.min-1 and elution with methanol (volume of 2,5 mL) without added salt. The use of the method SPE/GC-MS for to determination of levoglucosan in rainwater samples was in the range of concentration going from 0,05 to 0,50 g.mL-1, r 0,9967. The accuracy was 95-110%, determination of the inter assay precision gare coefficients of variation (CV) less than 15%, except for the limit of quantification (0,05 g.mL-1), for which CV was less than 20%. According to SPE/GC-MS determinations of levoglucosan in rainwater samples collected between 03/08/2011 and 09/04/2012, the average concentrations of this compound found during the harvest of sugar cane were approximately four times those obtained during the off-season. This fact is explained by the high rate of sugar cane burning in Ribeirão Preto-SP during harvest, which culminates in larger emissions of particulate matter to the atmosphere, including levoglucosano and COD, among others.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.