• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2005.tde-29042005-100303
Documento
Autor
Nombre completo
Julio César Ugucioni
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2005
Director
Tribunal
Mulato, Marcelo (Presidente)
Baffa Filho, Oswaldo
Ranieri, Izilda Marcia
Título en portugués
Iodeto de mercúrio (HgI2) para aplicações em detectores de radiação.
Palabras clave en portugués
caracterização estrutural
evaporação de solvente
iodeto de mercúrio
spray pyrolysis
Resumen en portugués
O iodeto de mercúrio(HgI2) vem sendo largamente estudado com o objetivo de utilizá-lo em detectores de radiação –X e –γ. Este material semicondutor apresenta propriedades interessantes que o tornam um grande candidato a esta aplicação em relação a outros materiais. Suas propriedades são gap óptico largo (2,13 eV), alto numero atômico (ZHg = 80; ZI = 53) e alto coeficiente de absorção para comprimentos de onda da ordem de energia do raios-X e -γ. Este, também, pode apresentar três fases quando sólido: fase vermelha (ou α-HgI2), fase amarela (ou β-HgI2) e fase laranja. Cada uma destas fases é associada com diferentes estruturas cristalinas. O α-HgI2 é tetragonal, o HgI2 laranja é também tetragonal,diferindo da fase vermelha somente na posição dos átomos de mercúrio, e β-HgI2 é ortorrômbico. Neste trabalho, estes materiais foram obtidos por duas técnicas: spray pyrolysis e evaporação de solvente. Nas duas técnicas os mais importantes parâmetros para a obtenção das diferentes estruturas são a temperatura e a taxa de evaporação do solvente. Através do método de spray pyrolysis foi possível obter filmes finos de HgI2 com duas estruturas diferentes, somente variando a temperatura do aquecedor de substratos e o solvente. Acima da temperatura de 100ºC com o solvente água foi possível obter filmes amarelados de HgI2. Por sua vez, a temperatura abaixo de 100ºC com o solvente etanol foi possível obter filmes avermelhados. Com a técnica de evaporação de solvente foi possível obter cristais e filmes laterais variando somente a taxa de evaporação de solvente. Variaram-se as taxas de evaporação entre rápida(~10ml/h), média(~0,5ml/h), lenta(~0,1ml/h) e super-lenta(~0,01ml/h). Para a taxa de evaporação média e lenta foram obtidos filmes laterais. Já para a taxa super-lenta foi possível obter cristais. Outro ponto estudado foi a influência da luz no crescimento dos cristais: no escuro obteve-se cristais maiores que os submetidos a luz ambiente. Todos os filmes foram caracterizados por difração de raios-X, microscopia eletrônica de varredura (MEV), e espectroscopia de dispersão de energia (EDS). Já os cristais foram caracterizados por difração de raios-X, MEV e espalhamento Raman.
Título en inglés
Mercuric iodide (HgI2) for applications in radiation detectors
Palabras clave en inglés
mercuric iodide
solvent evaporation
spray pyrolysis
structural characterization
Resumen en inglés
Recently, attention has been devoted to the study of mercuric iodide (HgI2) because this material is a strong candidate for the development of X- and γ -ray detectors. This material has an optical gap of 2.13 eV, high atomic number (ZHg = 80; ZI = 53) and high absorption coefficient for radiation in the wavelength region of X- and γ –rays. When solid, three phases can be obtained: red (or α-HgI2), yellow (or β-HgI2) and orange. Each of these phases has a different crystalline structure: α-HgI2 is tetragonal, as it is the orange- HgI 2 (the difference is that for the last one the mercury atoms sits in different positions), while the β-HgI2 is orthorhombic. In this work we obtained these materials using two different techniques: spray pyrolysis and solvent evaporation. For both of them the most important parameters are the deposition temperature and solvent evaporation rate. Thin films with two different structures were obtained by spray pyrolysis varying the substrate temperature and the solvent. Using water as solvent and deposition temperature above 100ºC we obtained yellow HgI2. When the temperature is reduced below that value and the solvent is ethanol, red films were obtained. For the solvent evaporation technique, lateral films and millimeter-sized crystals were obtained by varying the solvent evaporation rate. For ethanol as solvent we used four evaporation rates named as fast(~10ml/h), medium (~0.5ml/h), slow (~0.1ml/h) and super-slow (~0.01ml/h). For the medium and slow evaporation rates lateral films were obtained on the wall of the reservoir. For the super-slow evaporation rate crystals were obtained at the bottom of the reservoir. We observed that light has a tremendous influence on crystal growth: bigger crystals are obtained in the dark than under ambient light illumination. As characterization techniques we used: X-rays diffraction, Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), and Raman Scattering.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
JULIO-DISSERTACAO.pdf (3.76 Mbytes)
Fecha de Publicación
2005-05-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.