• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.59.2012.tde-26062012-160955
Document
Auteur
Nom complet
Jonatas Carrero Bloch
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2012
Directeur
Jury
Nicolucci, Patrícia (Président)
Goes, Evamberto Garcia de
Terini, Ricardo Andrade
Titre en portugais
Avaliação de técnicas radioterápicas conformacionais utilizando critérios físicos e biológicos
Mots-clés en portugais
Probalidade de controle tumoral
Radiobiologia
Radioterapia
Resumé en portugais
No combate às neoplasias, diferentes técnicas radioterápicas têm surgido, apoiadas em avanços tecnológicos, com o objetivo de otimizar a eliminação das células tumorais produzindo o menor dano a tecidos sadios dos pacientes. Os planejamentos de tratamentos radioterápicos visam o estabelecimento de parâmetros técnicos de irradiação de forma que as doses prescritas nos volumes de tratamento sejam atingidas. Enquanto que a prescrição das doses se baseiam em considerações biológicas de radiosensibilidade dos tecidos, os cálculos físicos do planejamento levam em conta parâmetros dosimétricos associados aos feixes de radiação e às características físicas dos tecidos irradiados. A incorporação de informações de sensibilidade de tecidos aos cálculos radioterápicos pode auxiliar na particularização de tratamentos e no estabelecimento de critérios de comparação e escolha de técnicas radioterápicas, contribuindo para o controle tumoral e sucesso do tratamento. Para tanto, modelos biológicos de resposta celular à radiação ionizante devem ser bem estabelecidos. Este trabalho visou estudar a aplicabilidade do uso de modelos biológicos em cálculos de planejamento radioterápico com objetivo de auxiliar na avaliação de técnicas radioterápicas. A probabilidade de controle tumoral (TCP) foi estudada para duas formulações do modelo linear-quadrático, com e sem consideração de repopulação celular, em função de parâmetros de planejamento, como dose por fração, e de parâmetros radiobiológicos, como a razão ?/?. Além disso, o uso de critérios biológicos para comparação de técnicas radioterápicas foi testado através da simulação de um planejamento de próstata utilizando simulação Monte Carlo com o código PENELOPE. Posteriormente, planejamentos radioterápicos de tumores de próstata de cinco pacientes do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, USP, utilizando-se três técnicas de irradiação diferentes, foram comparados através do critério de probabilidade de controle tumoral. Para tanto, matrizes de dose obtidas do sistema de planejamento radioterápico XiO foram utilizadas para obter as distribuições de TCP e histogramas TCP-volume. Os estudos realizados permitiram concluir que variações em parâmetros radiobiológicos podem influenciar significativamente cálculos de controle tumoral e que a análise de histogramas TCP-volume pode fornecer informações importantes para avaliação de tratamentos radioterápicos. Entretanto, o estabelecimento de fatores quantitativos de comparação através de critérios radiobiológicos passa pelo estabelecimento de protocolos de prescrição clínica baseados nesses critérios. Além disto, valores radiobiológicos sofreram grandes alterações na literatura recentemente e, portanto, a inclusão destes parâmetros nos cálculos de planejamentos requer grandes cuidados.
Titre en anglais
Evaluation of conformal radiotherapic techniques through physics and biologic criteria
Mots-clés en anglais
Radiobiology
Radiotherapy
Tumor control probability
Resumé en anglais
In the fight against cancer, different irradiation techniques have been developed based on technological advances and aiming to optimize the elimination of tumor cells with the lowest damage to healthy tissues. The radiotherapy planning goal is to establish irradiation technical parameters in order to achieve the prescribed dose distribution over the treatment volumes. While dose prescription is based on radiosensitivity of the irradiated tissues, the physical calculations on treatment planning take into account dosimetric parameters related to the radiation beam and the physical characteristics of the irradiated tissues. To incorporate tissue's radiosensitivity into radiotherapy planning calculations can help particularize treatments and establish criteria to compare and elect radiation techniques, contributing to the tumor control and the success of the treatment. Accordingly, biological models of cellular response to radiation have to be well established. This work aimed to study the applicability of using biological models in radiotherapy planning calculations to aid evaluating radiotherapy techniques. Tumor control probability (TCP) was studied for two formulations of the linear-quadratic model, with and without repopulation, as a function of planning parameters, as dose per fraction, and of radiobiological parameters, as the ?/? ratio. Besides, the usage of biological criteria to compare radiotherapy techniques was tested using a prostate planning simulated with Monte Carlo code PENELOPE. Afterwards, prostate plannings for five patients from the Hospital das Clínicas da Faculdadede Medicina de Ribeirão Preto, USP, using three different techniques were compared using the tumor control probability. In that order, dose matrices from the XiO treatment planning system were converted to TCP distributions and TCP-volume histograms. The studies performed allow the conclusions that radiobiological parameters can significantly influence tumor control calculations and that the TCP-volume histograms can provide important information for treatment techniques evaluation. However, the establishment of quantitative comparison parameters using radiobiological criteria demands the establishment of prescription protocols based on these same parameters. Also, the literature recently showed large variations in radiobiological parameters, meaning that the inclusion of those in treatment planning calculations should require a careful endeavor.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Blochcorrigida.pdf (3.32 Mbytes)
Date de Publication
2012-07-25
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.