• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2016.tde-25012016-163108
Documento
Autor
Nombre completo
Leonardo Diniz Hipolito Soares
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2015
Director
Tribunal
Poletti, Martin Eduardo (Presidente)
Moralles, Mauricio
Rinkel, Jean
Título en portugués
Análise de materiais biológicos usando o coeficiente de atenuação linear
Palabras clave en portugués
caracterização de tecidos
coeficiente de atenuação linear
mamografia
parametrização
Resumen en portugués
O conhecimento do coeficiente de atenuação linear (µ) é de extrema importância para estudos de contraste em imagens de radiodiagnóstico, dose e caracterização de materiais. Parâmetros como a densidade eletrônica (?e), o número atômico médio (Z¯), entre outros, podem ser determinados a partir do coeficiente de atenuação linear em diferentes energias. A proposta deste trabalho é determinar experimentalmente coeficientes de atenuação linear de 80 amostras de tecidos mamários (classificadas previamente como tecido adiposo, tecido glandular, fibroadenoma ou carcinomas) e, posteriormente, extrair parâmetros que possibilitem a caracterização e diferenciação desses tecidos. Os coeficientes de atenuação linear foram medidos usando geometria de feixe estreito, no intervalo de energia entre 10 e 50 keV, utilizando um tubo de raios X com anodo de tungstênio (W) e um detector dispersivo em energia de Si (SDD). Dois modelos de parametrizações foram utilizadas para extrair ?e e Z¯. As metodologias de determinação de µ e de parametrização foram validadas utilizando 8 materiais equivalentes a tecido (4 soluções e 4 sólidos). Os resultados obtidos para tecidos mamários foram comparados com predições teóricas, obtidas usando a regra das misturas, e com dados experimentais previamente publicados, apresentando diferenças máximas de até 7%. Foram também estudadas as variações de µ intra- e inter-amostras de um mesmo grupo, obtendo variações máximas de 5% e 12%, respectivamente. Foi mostrado que o coeficiente de atenuação linear consegue distinguir apenas o tecido adiposo dos demais grupos de tecidos para energia menores de 24 keV. Finalmente, foi elaborado um modelo de diagnóstico, baseados nos parâmetros ?e e Z¯. As análises estatísticas mostram que 71% das amostras foram classificadas corretamente.
Título en inglés
Biological Material Analisis using linear attenuation coefficients
Palabras clave en inglés
linear attenuation coefficient
mammography
parameterization
tissue characterization
Resumen en inglés
The knowledge of the linear attenuation coefficient (µ) is of extreme importance for radiodiagnostic image contrast studies, dose and material characterization. Parameters as electronic density (?e), average atomic number (Z¯), among others, can be determined using the linear attenuation coefficient at different energies. The purpose of this work is to experimentally determine the linear attenuation coefficient of 80 mammary tissues samples (classified as adipose tissue, glandular tissue, fibroadenoma or carcinoma) and then extract parameters that allow the characterization and differentiation of those tissues. The linear attenuation coefficients were measured using narrow bean geometry, with an energy interval between 10 and 50 keV, using a x-ray tube with a tungsten (W) anode and a Silicon energy dispersive detector (SDD). Two parameterization models were used to extract ?e and Z¯. The methodologies of determination of µ and parameterizations were validated using 8 tissue equivalent materials (4 solutions and 4 solids). The results obtained for mammary tissues were compared with theoretical predictions, using the mixture rule, and with previously published experimental data, presenting maximum differences of 7%. Intra and between samples variations of the same group were also studied, obtaining maximum variations of 5% and 12%, respectively. The linear attenuation coefficient was able to differentiate only the adipose tissue from others tissues groups, for energies below 24 keV. At last, a diagnostic model was elaborated, based on ?e and Z¯ parameters. The statistical analysis showed that 71% of the samples were correctly classified.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-02-16
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.