• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.59.2017.tde-23082017-210426
Documento
Autor
Nombre completo
Amanda Burg Rech
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2017
Director
Tribunal
Baffa Filho, Oswaldo (Presidente)
Abrego, Felipe Chen
Miranda, Diana Rodrigues de Pina
Nicolucci, Patrícia
Pavoni, Juliana Fernandes
Título en inglés
Campos pequenos de radiação e materiais alternativos em dosimetria com espectroscopia de ressonância magnética eletrônica
Palabras clave en inglés
Alanina
Alanine
Dosimetria
Dosimetry
Electron Magnetic Resonance
Minidosimeter
Minidosímetro
Ressonância magnética eletrônica
Resumen en inglés
Para acompanhar os avanços em radioterapia, os sistemas dosimétricos necessitam de aperfeiçoamento para garantir a acurácia do tratamento; e, paralelamente, a exposição radioativa vai além do uso clínico, sendo de interesse também a detecção em cenários radiológicos imprevistos. A espectroscopia de ressonância magnética eletrônica (RME) é capaz de detectar centros paramagnéticos criados em materiais expostos à radiação, relacionando resposta espectral com dose absorvida, executando assim a dosimetria de maneira não destrutiva, ao preservar a informação após a leitura. Após a padronização da alanina como detector de altas doses e a também aplicabilidade em estudos clínicos, dificuldades apresentadas propiciaram a investigação de outros materiais para dosimetria com RME; em contrapartida, classificar compostos presentes no cotidiano e com possibilidade de tecido equivalência é outro argumento para a expansão da análise de materiais alternativos. O desenvolvimento desta tese é entre dois tópicos distintos, porém interligados; primeiramente são apresentados minidosímetros para uso em campos pequenos, com abordagem clínica, e então a investigação de materiais alternativos, ambos para uso em dosimetria com RME. Em relação aos minidosímetros, o formato de pastilha é estudado, e são apresentados um novo conceito de detector, denominado EPResize®, e auditoria de ponta-a-ponta de um tratamento de radiocirurgia estereotáxica; sobre a investigação de materiais, foram estudados mais de 20 compostos, estes baseados em amônio, lítio, potássio e sódio. Os resultados mostraram que as dificuldades na determinação de dose com campos pequenos para um intervalo de dose clínico é uma questão que ainda necessita de muita atenção e adequação dos sistemas dosimétricos, de modo a extrair a maior sensibilidade possível, necessitando empregar parâmetros e métodos de análise além do rotineiramente utilizados; variados materiais se apresentaram adequados para a dosimetria com RME, tais como sulfato de amônio, formiato de sódio, ditionito de sódio, citrato de sódio e diferentes sulfitos, mesmo quando não satisfazendo aspectos clínicos, são alternativas para controle e determinação de doses em cenários não usuais. A capacidade de realizar a dosimetria com RME para campos pequenos e a padronização deste sistema possibilitam a verificação de tratamentos mais confiáveis em radioterapia não convencional; e a disponibilização de maior variedade de materiais para dosimetria com RME facilita a necessidade de mapeamento de dose em casos não previstos.
Título en inglés
Small radiation field and alternative materials in dosimetry with electron magnetic resonance spectroscopy
Palabras clave en inglés
Alanina
Alanine
Dosimetria
Dosimetry
Electron Magnetic Resonance
Minidosimeter
Minidosímetro
Ressonância magnética eletrônica
Resumen en inglés
To keep up with advances in radiotherapy, dosimetric systems need improvement to meet the standards established for treatment accuracy; simultaneously, radioactive exposure goes beyond clinical use, and the detection in unforeseen scenarios is of interest too. Electron magnetic resonance spectroscopy (EMR) can detect paramagnetic centers created in materials exposed to radiation, relating spectral response with absorbed dose, thus performing non-destructively dosimetry, by keeping the information after the readout. After standardization of alanine as a high dose detector and the applicability in clinical studies, difficulties allowed the investigation of other EMR dosimetry materials; on the other hand, classifying compounds that are present daily and with the possibility of tissue equivalence is another stimulus for the expansion of alternative materials analysis. The development of this thesis is between two distinct but interconnected topics; first minidosimeters are presented for small field dosimetry, with a clinical approach, and the investigation of alternative materials, both topics applied in EMR dosimetry. Concerning the minidosimeters, some pellets aspects are studied, a new concept of detector, called EPResize®; and a stereotactic radiosurgery end-to-end audit are presented; about alternative materials research, more than 20 compounds were studied, based on ammonium, lithium, potassium and sodium. The results showed that the difficulties in determining the dose with small fields in a clinical dose range is an issue that still needs much attention and adequacy of the dosimetric systems, in order to extract the greatest possible sensitivity, with the need to employ parameters and methods of analysis besides the daily used; several materials were adequate for EMR dosimetry, such as ammonium sulfate, sodium formate, sodium dithionate, sodium citrate and different sulfites, which, even when not satisfying clinical aspects, are alternatives for control and determination of doses in other scenarios. The ability to perform clinical dosimetry with RME and the standardization of this system allow the improvement of treatments accuracy, and the availability of a greater variety of EMR dosimetry materials facilitates the need for dose mapping unforeseen cases.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Corrigida.pdf (3.97 Mbytes)
Fecha de Publicación
2017-10-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.