Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.59.2014.tde-20052014-113830
Documento
Autor
Nome completo
Marcelo Barros Villa
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Ribeirão Preto, 2014
Orientador
Banca examinadora
Costa, Alessandro Martins da (Presidente)
Moralles, Mauricio
Nicolucci, Patrícia
Título em português
Estudo da função resposta de um detector cintilador de Nal(TI)
Palavras-chave em português
Cintilador
Espectrometria
Função resposta
Radiação
Radiação gama
Resumo em português
O conhecimento preciso do espectro energético de fótons é de extrema importância na radioterapia no que se refere à escolha adequada das doses a que os pacientes são submetidos. Os dados de saída dos detectores de radiação são apenas espectros de altura de pulso (PHD), ao invés de espectros de energia, que correspondem a informações distorcidas sobre a fonte e seus decaimentos devido a diversos erros associados ao processo de cintilação do cristal e à eletrônica. Os resultados medidos foram obtidos com o uso de um detector cintilador de NaI(Tl) e as simulações Monte Carlo foram feitas com o uso do programa EGSnrc. A partir das características do detector obtidas experimentalmente, nossas simulações puderam ser validadas para se aproximarem o mais próximo possível do caso real em laboratório. Dessas medidas experimentais de fontes radioativas de calibração e simulações, foi montada uma matriz resposta inversa que transforma PHD em espectro de energia de fótons. Uma vez que a faixa energética das fontes radioativas medidas teve um limite de 1.6MeV, a matriz resposta também o apresenta, mas que pode ser contornado de acordo com a geometria usada para a obtenção do PHD a ser corrigido. Observa-se que a resposta do detector é diretamente proporcional à energia e assim, dependendo da energia incidente a ser estudada, dois tipos de matriz resposta inversa podem ser aplicadas. Os resultados desta transformação de PHD para espectro de energia de fótons são apresentados.
Título em inglês
A Study on the Response Function of a NaI(Tl) Scintilation Detector
Palavras-chave em inglês
Gamma rays
Response function
Scintillator
Spectrometry
X-rays
Resumo em inglês
The accurate knowledge of the photon energy spectrum in radiotherapy is of extremely importance when it comes to the appropriate choice for doses whose patients are submitted. The output data from the radiation detectors is described as pulse high distributions, instead of energy spectra, that correspond to distorted information about the source and its decays due to many errors associated to the crystal scintillation process and the electronics. The measured results were obtained with a NaI(Tl) scintillation detector and Monte Carlo simulations were performed by the EGSnrc program. From the detector characteristics obtained experimentally, the simulations were validated so they could approximate the more real as possible as in laboratory. Using these simulated and experimental calibration sources, an inverse response matrix was built and transforms pulse high distributions in photons energy spectrum. Once the correction energy limit due to the radiation sources used is approximately 1.6 MeV, so the response matrix has a limit, but it can be overcame by the beam incident angle and the geometry used when the pulse high distributions to be corrected is going to be measured. One can realize that the detector response is directly proportional to the incident energy and, when it is intense as in a LINAC or weak as in a calibration source, different types of matrix can be applied. The results from these transformations are presented.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2014-09-24
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.