• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2006.tde-20042010-143652
Documento
Autor
Nombre completo
Paulo Cesar Dias Petchevist
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2006
Director
Tribunal
Almeida, Adelaide de (Presidente)
Caldas, Linda Viola Ehlin
Carvalho, Aparecido Augusto de
Título en portugués
Dosímetro FXGB para caracterização de feixes em radioterapia
Palabras clave en portugués
Dosímetro FXGB para Caracterização de Feixes em Radioterapia
Resumen en portugués
Desde a descoberta dos raios X por Wilhelm Conrad Roentgen em 1895, a medicina vem fazendo uso da radiação ionizante para o tratamento de alguns cânceres. No entanto, para que os tratamentos se façam com maior precisão, há a necessidade de um controle de qualidade adequado, que é da responsabilidade do físico médico de um serviço de radioterapia. Do aprimoramento do dosímetro químico Fricke em 2000 [BERO et al, 2000], através da adição de alaranjado de xilenol e gelatina de origem animal 300 Bloom, alcançou-se um aumento da sensibilidade e estabilidade da substância química. Porém, o custo da importação da gelatina e de um espectrofotômetro para as medidas de absorção óptica na determinação da dose absorvida poderia dificultar a utilização desse dosímetro num serviço de radioterapia. O presente trabalho busca apresentar uma alternativa simples e barata para atender às situações apresentadas através da substituição da gelatina importada por uma nacional (atualmente em teste) constituindo o novo dosímetro FXGB, que permitiu uma caracterização prévia de feixes de fótons (1,25 MeV) e elétrons (5, 7 e 10 MeV), além da determinação de parâmetros físicos para elétrons como fator e perfil de campo e porcentagem de dose profunda. As medidas foram realizadas com um protótipo leitor portátil (RADIARE III) desenvolvido [FELIPE, 2001] e otimizado [ZAIAS, 2006] em nosso grupo de pesquisa. Dessas medidas foi comprovado que o novo dosímetro é adequado para ser utilizado em medidas de dose absorvida na radioterapia para fótons e elétrons.
Título en inglés
FXGB Dosimeter for Beam Characterization in Radiotherapy.
Palabras clave en inglés
Dosimetry
FXGB Dosimeter
Radiotherapy
Resumen en inglés
Since the X rays discovery for Wilhelm Conrad Roentgen in 1895, the medicine started to use the ionizing radiation for some cancers treatments. However, to obtain higher precision in the treatments is necessary an adequate quality control, which is a medical physicist responsibility in the service. This work was developed to assist the medical physicist on the quality control through an simple, inexpensive and commercially accessible dosimetry. From the chemical dosimetry Fricke improvement in 2000 [BERO et al, 2000], through the orange xilenol and 300 Bloom gelatin addition, it was shown a sensibility and chemicalstability improvement. However, the high cost and difficulty to import the gelatin and necessity to utilize an spectrophotometer to determine the absorbed dose lead us to find another new gelatin adequate for the measurements. The new FXGB dosimeter was characterized for photons (1,25 MeV) and electrons (5, 7 and 10 MeV) and applied for some electrons beam physical determination as: field factor, field profile and depth dose percentage (PDD). From the obtained results, the FXGB dosimetric system (FXGB gel + prototype RADIARE III) show a promising option to assist the quality control in an radiotherapy service.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Paulo.PDF (1.10 Mbytes)
Fecha de Publicación
2010-08-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.