Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.59.2006.tde-20042010-143652
Document
Auteur
Nom complet
Paulo Cesar Dias Petchevist
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2006
Directeur
Jury
Almeida, Adelaide de (Président)
Caldas, Linda Viola Ehlin
Carvalho, Aparecido Augusto de
Titre en portugais
Dosímetro FXGB para caracterização de feixes em radioterapia
Mots-clés en portugais
Dosímetro FXGB para Caracterização de Feixes em Radioterapia
Resumé en portugais
Desde a descoberta dos raios X por Wilhelm Conrad Roentgen em 1895, a medicina vem fazendo uso da radiação ionizante para o tratamento de alguns cânceres. No entanto, para que os tratamentos se façam com maior precisão, há a necessidade de um controle de qualidade adequado, que é da responsabilidade do físico médico de um serviço de radioterapia. Do aprimoramento do dosímetro químico Fricke em 2000 [BERO et al, 2000], através da adição de alaranjado de xilenol e gelatina de origem animal 300 Bloom, alcançou-se um aumento da sensibilidade e estabilidade da substância química. Porém, o custo da importação da gelatina e de um espectrofotômetro para as medidas de absorção óptica na determinação da dose absorvida poderia dificultar a utilização desse dosímetro num serviço de radioterapia. O presente trabalho busca apresentar uma alternativa simples e barata para atender às situações apresentadas através da substituição da gelatina importada por uma nacional (atualmente em teste) constituindo o novo dosímetro FXGB, que permitiu uma caracterização prévia de feixes de fótons (1,25 MeV) e elétrons (5, 7 e 10 MeV), além da determinação de parâmetros físicos para elétrons como fator e perfil de campo e porcentagem de dose profunda. As medidas foram realizadas com um protótipo leitor portátil (RADIARE III) desenvolvido [FELIPE, 2001] e otimizado [ZAIAS, 2006] em nosso grupo de pesquisa. Dessas medidas foi comprovado que o novo dosímetro é adequado para ser utilizado em medidas de dose absorvida na radioterapia para fótons e elétrons.
Titre en anglais
FXGB Dosimeter for Beam Characterization in Radiotherapy.
Mots-clés en anglais
Dosimetry
FXGB Dosimeter
Radiotherapy
Resumé en anglais
Since the X rays discovery for Wilhelm Conrad Roentgen in 1895, the medicine started to use the ionizing radiation for some cancers treatments. However, to obtain higher precision in the treatments is necessary an adequate quality control, which is a medical physicist responsibility in the service. This work was developed to assist the medical physicist on the quality control through an simple, inexpensive and commercially accessible dosimetry. From the chemical dosimetry Fricke improvement in 2000 [BERO et al, 2000], through the orange xilenol and 300 Bloom gelatin addition, it was shown a sensibility and chemicalstability improvement. However, the high cost and difficulty to import the gelatin and necessity to utilize an spectrophotometer to determine the absorbed dose lead us to find another new gelatin adequate for the measurements. The new FXGB dosimeter was characterized for photons (1,25 MeV) and electrons (5, 7 and 10 MeV) and applied for some electrons beam physical determination as: field factor, field profile and depth dose percentage (PDD). From the obtained results, the FXGB dosimetric system (FXGB gel + prototype RADIARE III) show a promising option to assist the quality control in an radiotherapy service.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Paulo.PDF (1.10 Mbytes)
Date de Publication
2010-08-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.