• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.59.2020.tde-19112019-152927
Document
Auteur
Nom complet
Jaqueline Ramos Sousa Fernandes
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2019
Directeur
Jury
Bachmann, Luciano (Président)
Cardoso, George Cunha
Monte, Adamo Ferreira Gomes do
Moriyama, Lilian Tan
Titre en portugais
Determinação das propriedades ópticas de materiais altamente espalhadores
Mots-clés en portugais
Esfera integradora
Inverse Adding-Doubling
Materiais espalhadores
Propriedades ópticas
Resumé en portugais
A radiação óptica é amplamente utilizada na medicina para fins terapêuticos, cirúrgicos e diagnósticos. Tais aplicações tem incentivado a pesquisa de propriedades ópticas de tecidos biológicos com o intuito de descrever a propagação da luz. O tecido biológico, em termos de propriedades ópticas, é um meio túrbido, onde a propagação da luz é comprometida por processos de espalhamentos e absorção, que causam a perda da intensidade do feixe incidente, reduzindo a penetração da luz no tecido. As propriedades ópticas são obtidas principalmente por meio da conversão de fenômenos macroscópicos que podem ser medidos, tais como reflexão e transmissão, em propriedades microscópicas (coeficientes de absorção µa, espalhamento µ's e anisotropia g) que caracterizam o meio no qual a luz se propaga. Esse processo de conversão é baseado na solução da teoria de propagação da luz no tecido. Neste trabalho, empregamos um sistema com esferas integradoras duplas em associação com o método numérico Inverse Adding-Doubling (IAD) para determinar µa, µs e g de amostras altamente espalhadoras em diferentes comprimentos de onda. A partir das medidas experimentais de reflexão e transmissão das amostras, obteve-se os coeficientes pelo método IAD. As amostras avaliadas neste trabalho são phantoms de poliuretano, SEBS (do inglês styrene-ethylene-butylene-styrene) e de gelatina bovina. Os coeficientes obtidos para as amostras concordaram com os valores de referência e com a literatura, mostrando que o sistema implementado é capaz determinar µa e µ's de amostras altamente espalhadoras, assim como g para amostras delgadas. Como trabalho futuro é necessário empregar phantoms calibrados para verificar a exatidão do sistema desenvolvido.
Titre en anglais
Optical properties of turbid media
Mots-clés en anglais
Double integrating sphere
Inverse Adding-Doubling
Optical properties
Turbid medium
Resumé en anglais
Optical techniques are widely used in medicine, especially in surgery, diagnosis and therapeutic applications. Therefore, it is important to well understand the optical properties and the light propagation in biological tissues. The biological tissues are called turbid medium, which means it has a high optical scattering coefficient, causing a rapid decay on the incident light intensity, resulting in low light penetration. The optical properties usually are estimated by relating the macroscopic quantities one can measure, such as transmission and reflection of light to the microscopic quantities(absorption µa, scattering µs, and anisotropy g coefficients). This relationship is based on the light propagation theory. In this work, a double-integrating sphere system associated with the inverse adding-doubling (IAD) algorithm were employed to quantify the optical properties(µa, µs, and g) from highly scattering samples by measuring the reflection and transmission of the incident light at different wavelengths. The evaluated samples were phantoms made by three different materials: polyurethane, SEBS (styrene-ethylene-butylene-styrene) and bovine gelatin. The values of µa, µs, and g from the samples obtained by this system agree with reference and literature values, showing the viability for employing the implemented system to quantify µa and µs from highly scattering samples, as well as g from thin samples. As future work, it is necessary to study the accuracy of this system by using calibrated phantoms.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2020-05-13
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.