Master's Dissertation
DOI
https://doi.org/10.11606/D.59.2013.tde-19112013-115103
Document
Author
Full name
Guilherme de Oliveira Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2013
Supervisor
Committee
Mulato, Marcelo (President)
Bianchi, Rodrigo Fernando
Riul Júnior, Antonio
Title in Portuguese
Biossensor de ureia utilizando dispositivo pH-EGFET
Keywords in Portuguese
biossensor de ureia
EGFET
EnFET
FTO
sensor de íons.
Abstract in Portuguese
Sensores são dispositivos capazes de captar um determinado sinal físico -químico do meio e converte-lo num sinal elétrico mensurável por meio de um transdutor. Biossensor é um sensor que tem como parte funcional um receptor biológico específico a determinado analito alvo. Os sinais físico-químicos experimentados por estes dispositivos são convertidos em sinais elétricos de magnitude proporcional à concentração de um ou mais compostos químicos. Neste trabalho, foi construído um sensor de pH utilizando filmes finos comerciais de óxido de estanho dopado com flúor (FTO) como receptor a íons. O sensor foi feito ligando-se amostras de FTO ao terminal de porta de um transistor de efeito de campo do tipo MOS (Metal Oxide Semiconductor). Quando colocado em solução, os íons presentes interagem com a amostra sendo adsorvidos na superfície do filme de FTO. O potencial gerado pelos íons adsorvidos modulam a tensão na porta do transistor e, desta maneira, pode -se determinar a concentração dos íons presentes na solução de acordo com a magnitude da resposta do transistor. A este tipo de dispositivo dá -se o nome de EGFET (Extended Gate Field Effect Transistor). O EGFET construído apresentou responsividade de 55 mV/pH e resposta linear em soluções de pH 2 ao 12. Através de técnicas de imobilização enzimática foi possível ligar covalentemente proteínas urease sobre a superfície dos filmes de FTO, convertendo o sensor de pH em biossensor de ureia. Soluções tampão com diferentes pHs e concentrações foram testadas e determinou -se que as condições ideais para o uso deste biossensor de ureia são soluções tampão com pH = 6 e concentração de 10mM. Nessas condições, o biossensor apresentou uma responsividade de 114,5 mV/p(ureia) e linearidade no intervalo de concentrações de ureia entre 3,2.10 -4 e 3,2.10 -2 mol/L.
Title in English
Urea biosensor based on pH-EGFET technology.
Keywords in English
EGFET
EnFET
FTO
ion sensor.
urea biosensor
Abstract in English
Sensors are devices capable of capturing a certain physical-chemical signal from environment and convert it into a measurable electrical signal by a transducer. Biosensor is a sensor which has a biological sensing element as receptor specific to a particular target analyte. The physical-chemical signals experienced by these devices are converted into electrical signals with magnitude proportional to the concentration of one or more chemical compounds. In this work, we built a pH-sensor using commercial thin films of tin oxide doped with fluorine (FTO) as ions receptor. The sensor was made by linking FTO samples to the gate of a field effect transistor MOS type. In solution, the ions interact with the sample being adsorbed on the surface of FTO film. The potential generated by the ions adsorbed on film's surface modulate the gate voltage of the transistor and, in this way, we can determine the concentration of ions present in solution correlated with the magnitude of the transistor response. This kind of device is given the name of EGFET (Extended Gate Field Effect Transistor). The EGFET built exhibits sensitivity of 55 mV/pH and linear response in the range of pH 2 to 12. Through enzyme immobilization techniques we could covalently bind urease proteins on the surface of FTO film, changing the pH-sensor in urea biosensor. Buffer solutions with differents pHs and concentrations were tested and was determined that optimal environment conditions for this urea biosensor is buffer solutions with pH = 6 and 10mM of concentration. Under these conditions, the biosensor showed sensitivity of 114.5 mV/p(urea) and linear response in the range of 3,2.10 -4 to 3,2.10 -2 mol/L
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-04-02
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.