Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.59.2008.tde-16072008-114028
Document
Auteur
Nom complet
Alexandre Parizoti
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2008
Directeur
Jury
Ghilardi Netto, Thomaz (Président)
Costa, Alessandro Martins da
Furquim, Tânia Aparecida Correia
Titre en portugais
Otimização de imagens e proteção radiológica em fluoroscopia
Mots-clés en portugais
fluoroscopia
intervencionista
Otimização
otimização.
Resumé en portugais
Este trabalho teve como objetivo avaliar a proteção radiológica em procedimentos fluoroscópicos intervencionistas através de testes de controle de qualidade e levantamento radiométrico, bem como a implementação de um objeto simulador para avaliação da qualidade da imagem e sua otimização, com conseqüente redução da dose no paciente. O objeto simulador, desenvolvido para avaliação de equipamentos de radiologia convencional, mostrou-se eficaz na avaliação da qualidade da imagem em fluoroscopia, bem como na determinação dos níveis de taxa de kerma no ar na entrada da pele de um paciente adulto normal. A avaliação dos parâmetros técnicos dos diversos modos de exposição de um equipamento fluoroscópico digital permitiu estabelecer os indicadores de dose para otimização das imagens em procedimentos intervencionistas. Esta otimização possibilita reduzir a dose no paciente mantendo a qualidade da imagem e, conseqüentemente, sem perda de informação diagnóstica.
Titre en anglais
Optimizing Images and Radiological Protection in Fluoroscopy
Mots-clés en anglais
Fluoroscopy
Optimization and intervencionist.
Resumé en anglais
This work had as main objective to evaluate the radiological protection in the interventional procedures radiology through quality control and evaluations radiometric, as well as the implementation of a phantom for evaluation of the image quality and the consequent reduction of dose in the patient. The developed simulator object for equipment evaluation of conventional radiology had been revealed efficient in the evaluation of the quality of the fluoroscopic image, as well as in the determination of the entrance surface air kerma rate of the normal adult patient skin. The evaluation of the parameters technician in the diverse ways of exposition of digital fluoroscopy equipment allowed establishing the pointers of improve dose for improve the quality of the images in interventionist procedures. This makes possible to reduce the dose in the patient keeping the quality of the image and, without loss of diagnostic information.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Mestrado.pdf (1.50 Mbytes)
Date de Publication
2009-03-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.