Tesis Doctoral
DOI
https://doi.org/10.11606/T.59.2016.tde-13092016-114857
Documento
Autor
Nombre completo
Franciely Fernanda Schuch
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2016
Director
Tribunal
Nicolucci, Patrícia (Presidente)
Borges, José Carlos
Cecilio, Paulo José
Costa, Alessandro Martins da
Marin, Alfredo Viamonte
Título en portugués
Estudo e desenvolvimento de dosímetros luminescentes opticamente estimulados de a-Al2O3 com nanoestruturas de carbono e óxidos terras-raras para aplicação em radioterapia
Palabras clave en portugués
Al2O3
carbono grafite
Dosimetria OSL
nanoestruturas de carbono
Radioterapia.
terras-raras
Resumen en portugués
A alta sensibilidade e a reprodutibilidade de sinal são características de dosímetros luminescentes opticamente estimulados, que instigam seu uso no controle da qualidade e dosimetria in vivo em Radioterapia. Nesse trabalho, amostras de Al2O3, Al2O3 (1%C) e Al2O3 com diferentes concentrações de terras-raras e de nanoestruturas de carbono foram estudadas para aplicação em Radioterapia. As amostras foram obtidas pelo processo manual de mistura e maceração e inseridas em cápsulas transparentes, com exceção do material Al2O3 (1%C), que foi obtido na forma de pastilhas. Os sinais OSL para todos os materiais testados apresentaram crescimento de resposta com a dose de radiação. A concentração de 0,02% apresentou maior intensidade de sinal para todos os materiais inseridos na alumina, com exceção do carbono grafite (1%). Os materiais foram caracterizados por diferentes técnicas, para análises espectroscópicas e estruturais. A sensibilidade OSL do material Al2O3 (1%C) foi investigada para feixes de elétrons de 5 a 12 MeV, para feixe de fótons de 6 MV e para uma fonte de Irídio-192. Diferentes características dosimétricas OSL dos materiais Al2O3 (0,02%Eu), Al2O3 (0,02%Tb), Al2O3 (0,02%ntC), Al2O3 (0,02%npC) foram investigadas para feixes de fótons de 50 kVp, de 6 MV e para uma fonte de Irídio-192, em um amplo intervalo de doses. Todos os materiais apresentaram reprodutibilidade de sinal OSL (desvios menores que 1%) e homogeneidade de resposta em grupo de até ±95% (conferida para o dosímetro de Al2O3 (0,02%ntC). Todos os materiais estudados apresentaram sensibilidade satisfatória para doses de interesse clínico. Amostras OSL de Al2O3 (1% C), Al2O3 (0,02%ntC) e Al2O3 (0,02%npC) foram utilizadas para um estudo piloto de dosimetria in vivo em Radioterapia. A dosimetria in vivo sugere o possível uso dos dosímetros na rotina clínica em Radioterapia, através do estabelecimento de um protocolo de medidas, calibrações para cada feixe e energia utilizada e controle do sistema de planejamento utilizado para os cálculos de dose.
Título en inglés
Study and development of optically stimulated luminescent dosimeters of -Al2O3 with carbon nanostructures and rare-earth oxides for use in Radiotherapy
Palabras clave en inglés
Al2O3
carbono nanoestructures
earth-rares
graphte carbon
OSL Dosimetry
Radiotherapy
Resumen en inglés
High sensitivity and signal reproducibility are characteristics of optically stimulated luminescent dosimeter, instigating it use in quality control and in vivo dosimetry in Radiotherapy. In this work, samples of Al2O3, Al2O3 (1%C) and Al2O3 with different concentrations of rare-earth and carbon nanostructures, have been studied and developed for application in Radiotherapy. Samples were obtained by manual mixing and maceration and inserted into transparent capsules, except those of Al2O3 (1%C) which were produced as pellets. The OSL signals for all tested materials showed increasing response with radiation dose. The 0.02% concentration showed the highest signal intensity for all materials inserted into alumina, with exception to carbon graphite (1%). Materials were characterized by various techniques, through spectroscopic and structural analysis. The OSL sensitivity of Al2O3 (1%C) was investigated for electron beams from 5 to 12 MeV, 6 MV photons and an Iridium-192 source. Different dosimetric characteristics of some OSL materials Al2O3 (0.02%Eu), Al2O3 (0.02%Tb), Al2O3 (0.02%ntC), Al2O3 (0.02% npC) were investigated for photons beams of 50 kVp and 6 MV and a source of Iridium-192, in a wide dose range. All materials showed reproducibility of OSL signal (deviations less than 1%) and response homogeneity up to ± 95% (conferred for the dosimeter Al2O3 (0.02%ntC). All studied materials showed satisfactory sensitivity. Samples of Al2O3 (1%C), Al2O3 (0.02%ntC) and Al2O3 (0.02% npC) were used in a in vivo dosimetry pilot study in radiotherapy. The in vivo dosimetry performed with the developed OSL dosimeters suggest its possible use in clinical practice in Radiotherapy by establishing a measure protocol, calibrations for each beam and energy used and control of the planning system used for dose calculations.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-12-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.