• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.59.2011.tde-13062011-115106
Document
Auteur
Nom complet
Hermes Arytto Salles Kamimura
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2011
Directeur
Jury
Carneiro, Antonio Adilton Oliveira (Président)
Shimano, Antonio Carlos
Silva, Glauber José Ferreira Tomaz da
Titre en portugais
Vibroacustografia na avaliação tridimensional de artroplastia total de quadril
Mots-clés en portugais
artroplastia total de quadril
implantes
osso
transdutores matriciais
ultrassom
vibroacustografia
Resumé en portugais
A vibroacustografia (VA) é uma técnica de imagem de alta resolução lateral (<0,7 mm), livre de speckles, não invasiva e que utiliza radiação não-ionizante, baseada no fenômeno de combinação não-linear de ondas de ultrassom (MHz) que gera uma região focal estreita de baixa frequência (kHz). Neste trabalho, propõe-se uma avaliação tridimensional baseada em imagens de VA da área descoberta de implantes, após o procedimento cirúrgico de artroplastia total de quadril (ATQ). A ATQ é uma técnica terapêutica de substituição de articulações do quadril por implantes, em pacientes com osteoartrose avançada. Atualmente, o acompanhamento pós-operatório é auxiliado pela análise de radiografia plana por raios-X. Contudo, esta técnica apresenta limitações na avaliação da estabilidade dos implantes, tais como: avaliação imprecisa da área, uma vez que, a radiografia plana trata o problema tridimensional como bidimensional; impossibilidade de visualização de algumas regiões do implante, devido ao sobreposicionamento das regiões numa imagem planar; restrição do uso de radiação ionizante na região da pelve em pacientes jovens. Devido à alta atenuação da onda de ultrassom incidindo sobre objetos densos, a VA pode ser ajustada para adquirir imagens relativas, principalmente, à superfície destes. Uma correção da topologia baseada na geometria do implante é apresentada, a fim de se avaliar com precisão a área superficial na representação tridimensional da imagem de VA. A correção da topologia baseada em aquisições em modo-B também é apresentada, sendo útil na avaliação da forma de ossos ou nos casos em que a forma do objeto estudado é desconhecida. Além disso, é apresentado um estudo numérico da utilização de transdutores matriciais reconfiguráveis (RCA, do inglês reconfigurable array) para a formação de feixe em VA. Um estudo paramétrico da seleção de abertura, número de canais, número de elementos, distância focal e parâmetros de varredura eletrônica do feixe é apresentado para demonstrar a viabilidade e avaliar o desempenho da imagem de VA utilizando o RCA. A função de espalhamento de ponto do sistema foi calculada com base em métodos de espectro angular usando a aproximação de Fresnel para fontes retangulares. Foram discutidas as vantagens de transdutores bidimensionais e RCA, e aspectos relacionados à importância clínica da implementação do RCA na VA, tais como resolução espacial, taxa de aquisição da imagem e implementação do RCA em máquinas comerciais. Conclui-se que: a aquisição de imagens por VA foi menos sensível ao ângulo de incidência das ondas de ultrassom do que por modo-B e apresentou alta resolução e alto contraste entre o osso e o implante, o que permitiu uma avaliação precisa da área exposta do implante; os transdutores RCA podem aprimorar a aquisição de imagens por VA, devido à sua resolução espacial similar à de transdutores confocais e à possibilidade de deflexão eletrônica do feixe (em inglês steering) nos planos de elevação e azimutal.
Titre en anglais
Vibro-acoustography in the tridimensional evaluation of total hip arthroplasty
Mots-clés en anglais
bone
implant
reconfigurable array
total hip arthroplasty
ultrasound
vibro-acoustography
Resumé en anglais
Vibro-acoustography (VA) is a high lateral resolution (<0.7 mm), speckle-free, non- ionizing and non-invasive image based on the nonlinear combination phenomenon of ultrasound waves (MHz) that generates a narrow focus region of low frequency (kHz). In this work, we propose a VA-based tridimensional evaluation of the exposed area of implants, after total hip arthroplasty (THA). THA is a therapeutic surgery procedure in which the hip joints are replaced by metal prostheses in patients with advanced osteoarthritis. Currently, the postoperative assessment of THA is performed by analyzing planar X-ray radiographies. However, this technique presents limitations in the implant stability evaluation such as: inaccurate evaluation of the area, since the planar radiography reduces the tridimensional problem into a two-dimensional one; problems in the visualization of some regions of the implants due to the superimposition of the regions; limitations of using ionizing radiation in the pelvis region of young patients. Due to the high attenuation of the ultrasound wave into objects of high density, the VA image can be set to mainly acquire the surface information. Topological correction based on the geometry of the implant is presented in order to accurately evaluate the surface area in tridimensional representation of the VA image. The topological correction based on B-mode slices is also presented and is useful in the evaluation of bone shape or in cases which the shape of the object is unknown. Furthermore, it is presented a numerical study of the use of reconfigurable arrays (RCA) for VA beam formation. A parametric study of the aperture selection, number of channels, number of elements, focal distance and steering parameters is presented in order to show the feasibility and evaluate the performance of VA imaging based on RCA. The point-spread function of the system is calculated based on angular spectrum methods using the Fresnel approximation for rectangular sources. Advantages of two-dimensional and RCA arrays and aspects related to clinical importance of the RCA implementation in VA such as spatial resolution, image frame-rate, and commercial machine implementation are discussed. It is concluded that: the VA image is less sensitive to the wave incident angle than B-mode; the VA image presents high-resolution and high-contrast between bone and implant, which allowed an accurate evaluation of the uncovered area; RCA transducers improve the VA acquisition by producing spatial resolution similar to confocal transducers, and due to the possibility of steering in elevation and azimuthal planes.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-06-14
 
AVERTISSEMENT: Le matériau se réfère à des documents provenant de cette thèse ou mémoire. Le contenu de ces documents est la responsabilité de l'auteur de la thèse ou mémoire.
  • KAMIMURA, H A S, et al. Pressure transducer for measuring acoustic radiation force based on a magnetic sensor [doi:10.1088/0957-0233/22/1/015101]. Measurement Science and Technology [online], 2011, vol. 22, n. 1, p. 015101.
  • Kamimura, H A S, et al. Pressure transducer for measuring acoustic radiation force based on a magnetic sensor [doi:10.1088/0957-0233/22/1/015101]. Measurement Science & Technology [online], 2011, vol. 22, p. 015101-015108.
  • KAMIMURA, H. A. S., et al. Vibro-acoustography beam formation with reconfigurable arrays [doi:10.1109/TUFFC.2012.2343]. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control [online], 2012, vol. 59, n. 7, p. 1421-1431.
  • KAMIMURA, H. A. S., et al. Vibro-acoustography beam formation with reconfigurable arrays [doi:10.1109/tuffc.2012.2343]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control [online], 2012, vol. 59, p. 1421-1431.
  • KAMIMURA, HA, et al. Vibroacoustography for the assessment of total hip arthroplasty [doi:10.6061/clinics/2013(04)05]. Clinics [online], 2013, vol. 68, n. 4, p. 463-468.
  • KAMIMURA, HA, et al. Vibroacoustography for the assessment of total hip arthroplasty [doi:10.6061/clinics/2013(04)05]. Clinics (USP. Impresso) [online], 2013, vol. 68, p. 463-468.
  • URBAN, Matthew W., et al. Vibro-acoustography beam formation with reconfigurable arrays [doi:10.1121/1.3654717]. The Journal of the Acoustical Society of America [online], 2011, vol. 130, n. 4, p. 2425.
  • Almeida TWJ, Kamimura, HAS, and Carneiro AAO. A new apparatus for analysis of viscoelastic fluids by ultrasound radiation force. In (IEEE Engineering in Medicine and Biology Society Conference, Buenos Aires, 2010. Conf Proc IEEE Eng Med Biol Soc., 2010.
  • Almeida, T. W. J, Kamimura, HAS, e CARNEIRO, A. A. O. Transdutor de pressão arterial baseado em um sensor magnetorresistivo. In 21º Congresso Brasileiro de Engenharia Biomédica, Salvador, 2008. 21 CBEB., 2008. Resumo.
  • Almeida, T. W. J, Kamimura, HAS, e CARNEIRO, A. A. O. Transdutores de Pressão Arterial Baseado em um sensor magnetorresistivo. In 21 Congresso Brasileiro de Engenharia Biomédica, Salvador, 2008. 21 CBEB., 2008. Resumo.
  • BAGGIO, A., et al. SISTEMA PARA MEDIDAS DE VIBRO-ACUSTOGRAFIA. In III simpósio de Instrumentação e Imagens Médicas, São Carlos, 2007. III SIIM., 2007.
  • KAMIMURA, H. A. S., et al. Vibro-acoustography in the assessment of bone implant surface. In 2010 Mayo Graduate School - Annual Student Symposium, Rochester, 2011. Abstract Book., 2011. Abstract.
  • Kamimura, HAS, et al. Transdutor magnético para avaliar potência acústica. In Anais do PIBITI, São Paulo, 2008. PIBIT., 2008. Resumo.
  • Kamimura, HAS, et al. Transdutor magnético para avaliar pressão arterial. In Simpósio Internacional de Iniciação Científica da USP, São Paulo, 2008. 16 SIICUSP., 2008. Resumo.
  • Kamimura, HAS, ALMEIDA, E., e CARNEIRO, A. A. O. Transdutor de pressão ultra-sônico baseado em um sensor magnético. In 21º Congresso Brasileiro de Engenharia Biomédica, Salvador, 2008. 21 CBEB., 2008. Resumo.
  • KAMIMURA, Hermes A. S., et al. Vibro-acoustography and B-mode integration for 3D imaging [doi:10.1109/IEMBS.2011.6090055]. In 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society [online], Boston, MA, 2011. Boston, MA : IEEE, 2011. p. 421-424. ISBN 978-1-4244-4122-8.
  • MEDEIROS, L. J., et al. HIDROFONE BASEADO EM PIEZOELETRETOS PARA AQUISIÇÕES DE IMAGENS POR VIBROACUSTOGRAFIA. In XXIII Congresso Brasileiro de Engenharia Biomédica, Porto de Galinhas, 2012. XXIII CBEB2012., 2012. Resumo.
  • MEDEIROS, L. J., et al. Multi-layer piezoelectret hydrophone for ultrasonic applications [doi:10.1109/ULTSYM.2012.0629]. In 2012 IEEE International Ultrasonics Symposium, Dresden. 2012 IEEE International Ultrasonics Symposium. : IEEE, 2012.
  • Urban, Matthew, et al. Vibro-acoustography beam formation with reconfigurable arrays. In J. Acoust. Soc. Am.,, 2011. PROGRAM ABSTRACTS OF THE 162ND MEETING OF THE ACOUSTICAL SOCIETY OF AMERICA., 2011. Abstract.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.