• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.59.2018.tde-13042018-121618
Document
Author
Full name
Renan Hiroshi Matsuda
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2018
Supervisor
Committee
Baffa Filho, Oswaldo (President)
Caurin, Glauco Augusto de Paula
Mesquita, Rickson Coelho
Vargas, Claudia Domingues
Title in Portuguese
Desenvolvimento de funcionalidades no InVesalius Navigator e comparação de neuroimagem estrutural com o cérebro padrão MNI para EMTn
Keywords in Portuguese
Estimulação magnética transcraniana; Instrumentação; Neuronavegação
Abstract in Portuguese
A Neuronavegação é uma técnica de visualização computacional da localização de instrumentos em relação às estruturas neuronais. A estimulação magnética transcraniana (EMT) é uma ferramenta para estimulação cerebral não-invasiva, que tem sido utilizada em aplicações clínicas, para o tratamento de algumas patologias, e também em pesquisas. Entretanto, a EMT é uma técnica altamente dependente de parâmetros como o posicionamento e orientação da bobina de estimulação em relação às estruturas neuronais. Para auxiliar no posicionamento da bobina, uma combinação entre neuronavegação e EMT é utilizada, chamada de EMTnavegada (EMTn). Essa técnica permite o monitoramento em tempo real da bobina de EMT em relação às neuroimagens. Porém, a utilização da EMTn ainda é pouco explorada, tanto na pesquisa quanto no ambiente clínico, devido ao alto custo, exigência da imagem de ressonância magnética, complexidade e baixa portabilidade dos sistemas de EMTn comerciais. O neuronavegador de código aberto e livre, InVesalius Navigator, vem sendo desenvolvido para ajudar a suprir essa necessidade. Assim, o objetivo desta dissertação foi desenvolver ferramentas para o sistema de neuronavegação InVesalius Navigator. As funcionalidades adicionadas foram: i) suporte para três tipos de rastreadores espaciais; ii) sincronização da EMT com o neuronavegador; iii) guia para o reposicionamento da bobina. Além disso, com intuito de contornar a necessidade de utilizar a imagem de ressonância magnética foram realizados estudos para a substituição por uma imagem padrão. Na parte de desenvolvimento, experimentos de caracterização foram realizados para validação das ferramentas. O sistema de neuronavegação apresentou-se intuitivo e de fácil portabilidade. Além disso, a precisão obtida foi semelhante à de sistemas comerciais. Os erros de localização foram inferiores a 3 mm, considerados aceitáveis para aplicações clínicas. Na segunda parte, procedimentos que não exigem extrema precisão, como a localização e digitalização do hotspot, a variabilidade foi considerada aceitável. Portanto, a utilização da imagem média mostrou-se uma possível alternativa para as imagens de ressonância magnética.
Title in English
Development of functionalities for InVesalius Navigator and comparison of structural neuroimaging with standard MNI brain for EMTn
Keywords in English
Instrumentation; Neuronavigation; Transcranial magnetic stimulation
Abstract in English
Neuronavigation is a computer image-guided technique to locate surgical instruments related to brain structures. The transcranial magnetic stimulation (TMS) is a non-invasive brain stimulation method, it has been used for clinical purposes, treating neurological disorders, and also for research purpose, studying cortical brain function. However, the use of TMS is highly dependent on coil position and orientation related to brain structures. The navigated TMS (nTMS) is a combined technique of neuronavigation system and TMS, this technique allows tracking TMS coil by image guidance. Yet, nTMS is not widely used, either in research and in the clinical environment, due to the high cost, magnetic resonance imaging requirement, complexity, and low portability of commercial TMS systems. Thus, the aim of this dissertation was to develop tools for the neuronavigator system InVesalius Navigator, such as: i) support for three types of spatial trackers; ii) synchronization of the TMS with the neuronavigator; iii) guide for coil repositioning. In addition, in order to overcome the magnetic resonance imaging requirement, studies were made to replace it with a standard brain image. In the development part, characterization experiments were done to validate the new functionalities. Therefore, the accuracy obtained was similar to commercial systems. Localization errors were less than 3 mm considered acceptable for clinical applications. In the second part, for procedures that do not require extreme accuracy, such as the location and scanning of the hotspot, the variability was considered acceptable. Therefore, the use of the standard brain image was a possible alternative for magnetic resonance imaging.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-06-22
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.