• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.59.2013.tde-12112013-084219
Document
Auteur
Nom complet
Marcelo Menna Barreto Schwarcke
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2013
Directeur
Jury
Baffa Filho, Oswaldo (Président)
Ana, Lauro Wichert
Dantas, Bernardo Maranhão
Nicolucci, Patrícia
Silva, Ana Maria Marques da
Titre en portugais
Caracterização do gel polimérico MAGIC-f para aplicação em medicina nuclear utilizando imagens de ressonância magnética
Mots-clés en portugais
Dosimetria Gel Polimérica
Medicina Nuclear
Simulação Monte Carlo
Resumé en portugais
Este trabalho visa aprimorar e tornar mais precisa a utilização do dosímetro gel polimérico MAGIC-f no estudo da distribuição de dose para fonte radioativas utilizadas na terapia e diagnóstico em medicina nuclear. Para isso foram avaliados os parâmetros de leitura do gel em equipamentos de ressonância magnética e sua resposta quando comparado a resultados obtidos através da utilização do código PENELOPE de simulação Monte Carlo. Dentre as incertezas observadas no processo global da utilização do gel MAGIC-f, sua manufatura foi a que demonstrou uma maior preocupação uma vez que erro na frações de componentes químicos adicionados ocasiona grande diferença na resposta do dosímetro. A aquisição da informação dosimétrica em um equipamento de imagem por ressonância magnética demonstrou que tempos ao eco mais curtos são mais eficientes na diferenciação do sinal gerado no processo de polimerização devido a utilização de fontes de medicina nuclear do que ajustes na resolução da imagem e que a homogeneidade de campo magnético pode ocasionar grande alteração nos valores obtidos. Experimentos realizados com o gel MAGIC-f, demonstraram um baixa dependência energética e um grande dependência com a taxa de dose, dois fatores importantes em medicina, mas resultados simulados e experimentais comparativos utilizando fontes de I-131, Tc-99m e F-18, demonstraram uma grande precisão nos resultados apresentados, tornando assim o gel MAGIC-f uma excelente ferramenta na verificação volumétrica da dose absorvida na terapia com fontes de medicina nuclear.
Titre en anglais
MAGIC-f Gel Polimeric Caracterization for Nuclear Medicine Aplication using Magnética Ressonance Image
Mots-clés en anglais
Monte Carlo Simulation
Nuclear Medicine
Polymer Gel Dosimetry
Resumé en anglais
This work aims to improve and make more accurate use of the gel dosimeter MAGIC-f polymer in the study of dose distribution for radioactive source used in therapy and diagnosis in nuclear medicine. For this, MRI parameters reading of the gel were evaluated and its response when compared to results obtained using a Monte Carlo simulation PENELOPE code. Among the uncertainties observed in the overall use of MAGIC-f gel, its manufacturing demonstrated a greater concern since error in chemical fractions added causes big difference in the response of the dosimeter. The acquisition of dosimetric equipment information in a magnetic resonance imaging showed that the shorter eco times are more efficient in differentiating the signal generated in the polymerization process due to the use of sources of nuclear medicine than image resolution changes and the homogeneity of the magnetic field can cause large difference in the results. Experiments performed with the MAGIC-f gel, demonstrated a low energy dependence and a large dependence on the dose rate, two important factors in nuclear medicine, but comparative results with simulated and experimental processes using sources of I-131, Tc-99m and F-18 showed a great accuracy in results, thus making the MAGIC-f gel an excellent tool for volumetric verification of absorbed dose therapy with sources of nuclear medicine.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
V_Corrigida.pdf (17.83 Mbytes)
Date de Publication
2014-01-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.