Doctoral Thesis
DOI
https://doi.org/10.11606/T.59.2013.tde-11112013-115906
Document
Author
Full name
Lucas Sacchini Del Lama
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2013
Supervisor
Committee
Almeida, Adelaide de (President)
Caliri, Antonio
Caracelli, Ignez
Covas, Dimas Tadeu
Rodriguez, Mario Antonio Bernal
Title in Portuguese
Caracterização e adaptação do dosímetro Fricke para dosimetria em irradiação de sangue
Keywords in Portuguese
controle de qualidade
dosimetria e Doença Enxerto Contra Hospedeiro Associada à Transfusão (DECH-AT)
dosímetro Fricke Xilenol Gel
Irradiação de sangue
Abstract in Portuguese
A Doença Enxerto Contra Hospedeiro Associada à Transfusão (DECH-AT) é uma reação transfusional rara, porém fatal, que ocorre devido à presença de células T no sangue doado e que pode ser prevenida por meio da irradiação do sangue do doador e de seus componentes antes da transfusão. Assim, o controle de qualidade associado à irradiação do sangue é necessário para se garantir a qualidade do produto transfundido. Neste trabalho é proposta a caracterização e a adaptação da resposta do dosímetro Fricke para uso na dosimetria da irradiação de sangue, mais especificamente o Fricke Xilenol Gel (FXG). Este é um dosímetro químico radiocrômico, que apresenta as vantagens de ser tecido equivalente e de permitir a inferência espacial da dose absorvida dentro da faixa de doses usados na prevenção DECH-AT. Dessa maneira, de modo a possibilitar a inferência de dose absorvida em todo o intervalo utilizado na prevenção da DECH-AT (25 a 50 Gy), o FXG foi caracterizado e adaptado para aplicações dosimétricas envolvendo a irradiação de sangue e derivados. Os resultados com o novo dosímetro apontaram adequabilidade para toda a faixa necessária de doses absorvidas, com sensibilidade e desvanecimento temporal satisfatórios para aplicações rotineiras. Além disso, pela metodologia proposta neste trabalho, foi possível determinar as distribuições espaciais das doses absorvidas com o dosímetro proposto de uma maneira rápida e simples, mostrando assim que este dosímetro apresenta características convenientes para o controle de qualidade para a dosimetria da irradiação de sangue e de hemocomponentes.
Title in English
Characterization and Adaptation of Fricke Dosimeter for Blood Irradiation Dosimetry
Keywords in English
Blood irradiation
Dosimetry
Fricke Xylenol Gel dosimeter
Quality assurance
Transfusion-Associated Graft versus Host Disease (TA-GvHD)
Abstract in English
The Transfusion Associated Graft Versus Host Disease (TA-GVHD) is a rare transfusion reaction, however fatal, which develops due to the presence of donor T lymphocytes in the donated blood and that can be avoided by the irradiation of the donated blood blood and blood components prior to transfusion. Thus, the associated quality control of blood irradiation is necessary to guarantee the quality of the transfused product. In this work it is proposed the characterization and adaptation of the response of a Fricke dosimeter to be used for dosimetry of blood irradiation, more especiafically the Fricke Xylenol Gel (FXG). This is a radiochromic chemical dosimeter, which presents advantages to be tissue equivalent and allows the spatial absorbed dose inference. In this manner, in a way to possibilitate the absorbed dose inference in the full interval used for the prevention of the TA-GVHD (25 to 50 Gy) the FXG was characterized and adapted for dosimetry applications involving blood and blood components irradiation. The results with the new dosimeter showed adequability for the necessary absorbed doses, with satisfactory sensibility and time fading for routine applications. Furthermore, according to the methodology proposed in this work, it was possible to determine the spatial absorbed dose distributions with the new dosimeter in an fast and simple way, showing that this dosimeter presents convenient characteristics for dosimetry quality control of irradiated the blood and blood components.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
corrigida.pdf (28.67 Mbytes)
Publishing Date
2014-02-06
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI