Título en portugués
Montagem e caracterização de um fantoma para utilização em radioterapia utilizando imagens convencionais por ressonância magnética e contraste por transferência de magnetização
Palabras clave en portugués
dosimetria
gel
imagem porressonância magnética
radioterapia
Resumen en portugués
A dosimetria 3D utilizando gel à base de monômeros é uma importante ferramenta utilizada em casos de Radioterapia, em que há necessidade de uma alta resolução da distribuição espacial de dose. Neste trabalho, desenvolvemos um gel à base de monômeros do acido metacrilico, denominado MAGIC®, com a finalidade de avaliar a distribuição espacial de dose em simulações de tratamento de radioterapia, utilizando duas técnicas de imagens por ressonância magnética, Magnetic Resonance Imaging (MRI): a relaxometria (RT) e a transferência de magnetização (Magnetization Transfer, MT). Para tal, o trabalho foi desenvolvido em três etapas. Na primeira, desenvolvemos fantomas para serem irradiados com radiação ? e x, sobre os quais imagens de ressonância foram obtidas e analisadas. Desenvolvemos também um software, escrito em Matlab®, para analisar as imagens e traçar curvas de isodose dos fantomas irradiados. Em seguida, aperfeiçoamos o preparo, a composição, e as maneiras de adquirir e processar as imagens do gel irradiado. Nessa etapa incorporamos o formaldeido ao gel MAGIC, aumentando sua sensibilidade em 15%. Por fim, simulamos cinco configurações de tratamento de radioterapia e avaliamos as isodoses adquiridas, comparando-as com aquelas obtidas pelo software de planejamento radioterápico virtual, TPS®. As avaliações feitas com a técnica de relaxometria corresponderam às nossas expectativas. Com ela foi possível caracterizar o gel MAGIC, com alguns testes dosimétricos, bem como avaliar as 5 simulações de tratamentos radioterápicos propostas. O gel se mostrou linear até 20 Gy, mas não apresentou níveis aceitáveis de reprodutibilidade, necessitando de uma curva de calibração em cada teste. O gel possui número atômico efetivo próximo ao da água não necessitando de fatores de correções. Na maioria dos casos simulados, as isodoses das simulações feitas com o gel MAGIC reproduziram as simulações virtuais. Infelizmente, não obtivemos, por enquanto, o mesmo sucesso com a avaliação por MT. As imagens de MT não se mostraram confiáveis e por esse motivo as simulações com o gel só foram feitas com a técnica de RT.
Título en inglés
Phanton developing and caractherizing for radiotherapy using conventional magnetic resonance imaging and magnetization transfer contrast
Palabras clave en inglés
dosimetry
gel
magnetic resonance imaging
radiotherapy
Resumen en inglés
The 3D monomeric gel dosimetry is an important tool in radiation therapy cases which needs high spatial dose resolution. In this work we developed a methacrilic acid monomeric gel called MAGIC® to evaluate spatial dose distributions in simulations of radiation therapy treatments. We used two Magnetic Resonance Imaging (MRI) techniques, the relaxometry (RT) and the magnetization transfer (MT). The work was developed in three stages. First of all, the phantoms were created to be irradiated using and x radiations, the MRI were acquired and analyzed. We also developed a software, programmed in Matlab®, to analyze the images and to draw isodoses curves of irradiated phantoms. Following it, we improved the way the gel was prepared and its composition, as well the image acquisition and processing. In this part we added formaldehyde to the gel, improving its sensibility in 15%. Finally, we simulated 5 different radiation therapy treatments and compared the isodoses measured with the isodoses of the radiation therapy treatment planning software (TPS®). The results of the RT technique corresponded to our expectations. Using the RT we characterized the gel with dosimetric tests and evaluated five different radiation therapy treatments. The gel showed a linear relation with the dose until 20 Gy, but the results of the tests were not reproducibles, because of that we made a calibration curve for each test. The effective atomic number of the gel is close to the water, so it was not necessary any correction. In most of the simulated cases, the isodoses measured with the gel reproduced the virtual simulations. Unfortunately, until now, we didn' t have the same success using the MT technique. The MT images were not reliable and because of that the simulations were only made with the RT technique.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-09-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.