Titre en portugais
Dosimetria gel no controle de qualidade tridimensional em tratamento de radioterapia com intensidade modulada e técnica SMART (Simultaneous Modulated Accelerated Radiation Therapy)
Mots-clés en portugais
Gel MAGIC-f; Radioterapia de Intensidade modulada; Técnica SMART.
Resumé en portugais
A radioterapia com intensidade modulada de feixe (IMRT) possibilitou a realização de tratamentos de múltiplos alvos simultaneamente em um esquema de tratamento acelerado conhecido como SMART (Simultaneous Modulated Accelerated Radiation Therapy). Estes tratamentos requerem um rigoroso controle de qualidade (QA) que deveria ser realizado, idealmente, em três dimensões. Uma potencial ferramenta para dosimetria tridimensional (3D) é o uso de gel polimérico associado à leitura de doses com Imagens de Ressonância Magnética Nuclear (IRMN). Neste trabalho, a dosimetria 3D com o gel MAGIC-f foi aplicada no CQ de 10 planejamentos radioterápicos usando a técnica SMART. Inicialmente, as distribuições de dose dos planejamentos avaliados foram recalculadas na geometria do simulador baseadas em sua tomogra_a computadorizada. Todos os planejamentos utilizados foram aprovados previamente no QA convencional pontual e planar, o que validou a distribuição de dose do sistema de planejamento (TPS) para comparação com a dosimetria gel. Os simuladores foram irradiados com os planejamentos estabelecidos e as distribuições de dose foram obtidas através da relaxometria em IRMN. A comparação das distribuições de dose calculadas pelo TPS e as medidas no gel foi feita pela análise gama (3%/3mm) e pela comparação entre os histogramas dose-volume (DVHs) calculados e medidos para dois volumes criados nas regiões equivalentes aos volumes alvo de tratamento. Esses resultados evidenciam o potencial do uso da dosimetria gel polimérica no QA 3D de planejamentos de IMRT com a técnica SMART, fornecendo informação completa 3D da dose absorvida em cada volume alvo planejado, desde que realizada seguindo os protocolos pré-estabelecidos.
Titre en anglais
Gel Dosimetry in Tridimensional Quality Control Radiotherapy Treatments with Intensity Modulated and SMART Technique (Simultaneous Modulated Accelerated Radiation Therapy).
Mots-clés en anglais
Gel MAGIC-f; IMRT; SMART.
Resumé en anglais
Intensity Modulated Radiation Therapy (IMRT) treatments in the radiotherapy practice made possible the simultaneously treatment of multiple targets at an accelerated treatment regimen, this scheme is known as Simultaneous Modulated Accelerated Radiation Therapy (SMART). These treatments require a strict quality control (QC) that should be done, ideally, in three dimensions. A potential tool for tridimensional dosimetry (3D) is the use of polymeric gel with Nuclear Magnetic Resonance Images (NMRI). In this paper, the 3D dosimetry with MAGIC-f gel was applied in 10 QC radiotherapy planning using the SMART technique. Initially, the dose distributions of assessed plans were remeasured in simulator geometry based on a CT scan. All plans used were previously approved in punctual and planar conventional CQ, which validated the dose distribution planning system (TPS) for comparison with the gel dosimetry. The simulators were irradiated with established schedules and dose distributions were obtained by relaxometry in NMRI. The comparison of dose distributions calculated by TPS and measured in the gel was made by gamma analysis (3% / 3mm) and by comparing the dose-volume histograms (DVHs) calculated and measured for two volumes created in the equivalent regions to target volumes of treatment. These results highlight the potential use of the polymer gel dosimetry in IMRT planning 3D CQ with SMART technique, providing complete 3D information of the absorbed dose in each target volume planned, if carried out following the pre-established protocols.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
ErickRundo.pdf (24.52 Mbytes)
Date de Publication
2017-11-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.